nvent SCHROFF 11850-016 Manuale utente

User Manual
1 U MTCA Shelf
Product Number:
11850-016
Doc-No: 63972-350_R1.0 February 2016

R1.0 February 2016 Initial release
Impressum:
Schroff GmbH
Langenalber Str. 96 - 100
75334 Straubenhardt, Germany
The details in this manual have been carefully compiled and
checked - supported by certified Quality Management System
to EN ISO 9001/2000
The company cannot accept any liability for errors or misprints.
The company reserves the right to amendments of technical
specifications due to further development and improvement of
products.
Copyright2016
All rights and technical modifications reserved.

11850-016
R1.0, February 2016 I
1 Safety ....................................................................................................................... 1
1.1 Safety Symbols used in this document.............................................................................. 1
1.2 General Safety Precautions ............................................................................................... 1
1.3 References and Architecture Specifications...................................................................... 1
2 Hardware Platform ................................................................................................... 2
2.1 Front and Rear View.......................................................................................................... 3
2.2 ESD Wrist Strap Terminal .................................................................................................. 3
3 Backplane ................................................................................................................. 4
3.1 Backplane Topology .......................................................................................................... 4
3.2 Fabric Interface ................................................................................................................. 5
3.2.1 Common Options............................................................................................... 5
3.2.2 Fat Pipe .............................................................................................................. 5
3.2.3 Extended Fat Pipe .............................................................................................. 5
3.3 Intelligent Platform Management Bus (IPMB) .................................................................. 5
3.3.1 IPMB-L................................................................................................................ 5
3.4 Power Management.......................................................................................................... 5
4 Cooling ..................................................................................................................... 6
4.1 Air Filter............................................................................................................................. 6
4.2 Air filter swap .................................................................................................................... 6
4.3 Cooling .............................................................................................................................. 6
4.4 Power Supply..................................................................................................................... 7
5 EMCH (Embedded MicroTCA Carrier Hub)................................................................. 8
5.1 Front Panel and LEDs......................................................................................................... 9
5.2 Comand Line Interface (CLI) ............................................................................................ 10
5.2.1 COM-Settings ................................................................................................... 10
5.3 Firmware Update ............................................................................................................ 11
6 Technical Data ........................................................................................................ 12

11850-016
II R1.0, February 2016

11850-016
R1.0, February 2016 Safety 1
1 Safety
The intended audience of this User’s Manual is system integrators and hardware/software
engineers.
1.1 Safety Symbols used in this document
1.2 General Safety Precautions
• Use of this product in a manner not specified by the manufacturer may impair the safety protec-
tion of this equipment.
• Service personnel must know the necessary electrical safety, wiring and connection practices for
installing this equipment.
• Install this equipment only in compliance with local and national electrical codes.
• For additional information about this equipment, see the PICMG MicroTCA
Specification (www.picmg.com).
1.3 References and Architecture Specifications
•PICMG
®MTCA.0 Specification
(www.picmg.com)
•PICMG
®AMC® Base Specification
(www.picmg.com)
Hazardous voltage!
This is the electrical hazard symbol. It indicates that there are dangerous voltages inside the
Shelf.
Caution!
This is the user caution symbol. It indicates a condition where damage of the equipment or
injury of the service personnel could occur. To reduce the risk of damage or injury, follow all
steps or procedures as instructed.
Danger of electrostatic discharge!
The Shelf contains static sensitive devices. To prevent static damage you must wear an ESD
wrist strap.
Warning!
Voltages over 60 VDC can be present in this equipment. As defined in the PICMG 3.0 Speci-
fication, this equipment is intended to be accessed, to be installed and maintained by
qualified and trained service personnel only.

11850-016
2Hardware Platform R1.0, February 2016
2 Hardware Platform
The Schroff 11850-016 is an 1 U/2slot MicroTCA Shelf with EMCH (Embedded MicroTCA
Carrier Hub) for AMC Single Full-size or Mid-size modules (with 2 HP filler panel).
Features:
• Shielded steel case
• 2 AMC single Full-size slots
• MicroTCA Backplane
• EMCH (Embedded MicroTCA Carrier Hub) with basic MicroTCA functionality for switching
and managing two AMCs (Advanced Mezzanine Cards)
• Power management controller on the backplane
• Active cooling through:
4 fans for cooling the AMC modules
1 fan for cooling the power supply
• Easy removable air inlet filter
• Integrated 150 W AC Power Supply with wide range AC input and 12 V DC output.
• AC mains/line module with IEC 320-C14 connector, integrated mains/line fuses and line
filter

11850-016
R1.0, February 2016 Hardware Platform 3
2.1 Front and Rear View
Figure 1: Front and RearView
2.2 ESD Wrist Strap Terminal
The ESD Wrist Strap Terminal (4 mm banana jack) is located left to the card cage.
1ESD Wrist Strap Terminal 5EMCH interfaces
22 HP Filler panel 6Ground Terminal (Equipotential bonding)
3AC input 7PSU
4Mains/line switch 8EMCH
Danger of electrostatic discharge!
The Shelf contains static sensitive devices. To prevent static damage you must wear an ESD
wrist strap.

11850-016
4Backplane R1.0, February 2016
3 Backplane
• 3.3 V management power generation on the backplane
• Hot-Swap circuitry for enabling the management power and payload power by the EMCH
• Fan connectors on the backplane (4-pin fan connectors)
3.1 Backplane Topology
Figure 2: Backplane Topology
AMC1 AMC2
Fabric 1/A (1000Base-BX)
Clocks - FCLKA AMC
(1:1 connection)
Clocks - TCLKB AMC (Output)
Clocks - TCLKC AMC
Clocks - TCLKD AMC (Output)
Clocks - TCLKA AMC
IPMB_L
DC/DC
Converter
+3,3V
HotSwap
AMC Port 2 (SATA)
AMC Port 3 (SATA)
MCH
AMC Port 4-7
(FAT PIPE)
Port 0
Port 1
Fabric 2/A (1000Base-BX)
Common Options
Port 2
Port 3
A
4Port 4-7
A
BB
CC
DD
FAN1 FAN 2 FAN3
FAN4 FAN 5
+12V
FAN _Control
PPWR_2
PPWR_1
PPWR
MP_2
PRESENT_1
MP
I²C
Carrier Number
+12V FAN_Tacho
5
EN_HSC_1
Current
Sense
EEPROM
FRU
PRESENT_2
EN_AMC1
MP_1
EN_AMC2
IR_HotSwap
4
AMC Port 8-11
(EXT.FAT PIPE)
Port 8-11

11850-016
R1.0, February 2016 Backplane 5
3.2 Fabric Interface
3.2.1 Common Options
MCH Fabric Port 1 is routed to AMC 1 Port 0.
MCH Fabric Port 2 is routed to AMC 2 Port 0.
MCH Fabric Port 3 is routed to AMC 1 Port 1.
MCH Fabric Port 4 is routed to AMC 2 Port 1.
AMC Ports 2 and 3 are direct slot to slot connections between both AMC slots.
3.2.2 Fat Pipe
AMC slots Port [4:7] are direct slot to slot connections between both AMC slots.
3.2.3 Extended Fat Pipe
AMC slots Port [8:11] are direct slot to slot connections between both AMC slots.
3.3 Intelligent Platform Management Bus (IPMB)
MicroTCA uses an Intelligent Platform Management Bus (IPMB) for management
communications.
3.3.1 IPMB-L
Radial IPMB from MCH to both AMCs.
3.4 Power Management
The integrated power management circuitry on the backplane provides 12 V payload power
distribution branches to the AMC Slots. It also generates the 3.3 V management power and
distributes it to all slots.
The current to the AMC slots is limited to:
•8A(PayloadPower)
• 250 mA (Management Power)

11850-016
6Cooling R1.0, February 2016
4 Cooling
4.1 Air Filter
Figure 3: Air Filter
4.2 Air filter swap
The system provides a replaceable air filter. The air filter can be pulled out after removing the top
cover. The filter meets the requirements of the Telcordia Technologies Generic Requirements GR-78-
CORE specification.
4.3 Cooling
Figure 4: Airflow
The MicroTCA Shelf is equipped with four 12 VDC fans for cooling the AMC modules and one 12 VDC
fan for cooling the power supply. The fans are controlled as a group by the EMCH.
e
1Air Filter