OfiTE 2040 Manuale utente

Model 2040 Automated HTHP Consistometer
#120-40 - Consistometer
#120-40-DAS - With Computer
Instruction Manual
Updated 3/22/2021
Ver. 1
OFI Testing Equipment, Inc.
11302 Steeplecrest Dr. · Houston, Texas · 77065 · U.S.A.
Tele: 832.320.7300 · Fax: 713.880.9886 · www.ote.com
©Copyright OFITE 2021

OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ote.com 1
Requirements .................................................................................3
Intro..................................................................................................3
Description......................................................................................3
Features...........................................................................................3
Specications .................................................................................4
Components ...................................................................................4
Safety...............................................................................................7
Quick Start ......................................................................................9
Starting a Test.............................................................................9
Completing a Test .....................................................................10
Setup.............................................................................................. 11
Software ........................................................................................16
General Setup...........................................................................16
Setup.........................................................................................17
Prole Builder............................................................................19
Main Screen..............................................................................21
Events .......................................................................................24
Calculated Values .....................................................................25
Onboard Display...........................................................................26
Real-Time Data.........................................................................27
Test Setup - Test Cong............................................................28
Test Setup - Prole....................................................................29
Calibrate....................................................................................30
Utilities.......................................................................................31
Archive ......................................................................................32
Manual Control..........................................................................33
Start Test...................................................................................34
Operation ......................................................................................35
Filling the Slurry Cup.................................................................35
Starting a Test ...........................................................................37
Completing the Test ..................................................................39
Table of
Contents

OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ote.com 2
Maintenance .................................................................................40
Cleaning....................................................................................40
Potentiometer ...........................................................................42
Rupture Disk .............................................................................44
Oil Filter.....................................................................................45
Pressure Relief Valve Regulator...............................................46
Troubleshooting.........................................................................47
Calibration.....................................................................................51
Potentiometer ...........................................................................51
Value Chart ...............................................................................53
Pressure....................................................................................54
Temperature..............................................................................55
Appendix .......................................................................................56
Metal Seal Ring Installation ......................................................56
Cell Diagram .............................................................................59
Slurry Cup Diagram ..................................................................60
Potentiometer Diagram .............................................................62
Potentiometer Adjustment.........................................................63
Fuses and Breakers..................................................................64
Multiple Instruments..................................................................65
Warranty and Return Policy ........................................................66

OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ote.com 3
During cementing operations, the time required for a cement slurry to set is
of primary concern. Under an ideal situation, minimal time would be required
to successfully pump the slurry, which immediately upon placement, begins
to develop compressive strength. However, if insucient time is allowed to
fully pump the cement, it will be necessary to drill the cement remaining in the
casing string. Remedial operations such as this are very costly. Conversely,
cements that are successfully placed, but require considerable time to
cure, consume valuable rig time, which is also quite costly. Laboratory tests
should be conducted under simulated reservoir conditions to examine the
actual thickening time of the slurry. The OFITE HTHP Consistometer was
specically engineered to determine the thickening time of well cements
under simulated downhole pressures and temperatures.
A cement is mixed and poured into the slurry cup assembly. The slurry cup
is placed into the test vessel and pressure is increased via an air-driven
hydraulic pump. A PID temperature controller governs an internal heater,
which maintains the necessary temperature prole, while a magnetic drive
mechanism rotates the slurry cup assembly. A potentiometer controls an
output voltage, which is directly proportional to the amount of torque the
cement exerts upon an API-approved paddle. The included software controls
the instrument and records temperature, pressure, and cement consistency
as a function of time.
- Touch screen display for standalone operation
- Computerized Data Acquisition and Control system provides detailed test
information in convenient formats and can control multiple units from one
computer. RS-232, Ethernet, and USB connections available.
- Automatic temperature and pressure control
- External cooling jacket aids cooling of test cell
- Automatic, programmable speed motor (0 – 300 RPM) powered by a
magnetic drive
- Easy-to-use two-piece lift-o cap for pressure cell
- Drip tray next to cap provides a place to set the cap between tests without
dripping oil on the unit casing
- Convenient oil reservoir features a cap with built-in funnel to help prevent
spills, a removable top and bottom that make cleaning easy, and a sloping
bottom that collects sediment for easy removal
- Visual indicator provides an at-a-glance status update during testing
- Small footprint saves valuable lab space
- Temperature, pressure, and consistency alarms provide automatic
shutdown for safety
- Conforms to API Specication 10 guidelines
- Air/Nitrogen Supply (100 – 120 PSI / 689.5 – 827.4 kPa)
- Water Supply for Cooling (40 PSI / 276 kPa)
- Water Drain
- 220 Volt, 50/60 Hz, 25 Amp electrical power supply
Intro
Description
Features
Requirements

OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ote.com 4
Specications Size 22.5" × 27.5" × 70"
Weight Approximately 450 lb
Crated Size 26" × 34" × 76"
Crated Weight Approximately 750 lb
Temperature Controller Digital with 0.1° Resolution
Pressure Indicator Digital transducer with 1 PSI (0.1 MPa)
resolution. Analog gauge.
Slurry Cup Variable Speed: 0 – 300 RPM
Max Temperature 600°F (315.5°C)
(For tests above 400°F, refer to page 12)
Max Pressure 40,000 psi (276 MPa)
#120-001 Mineral Oil, 1 Gallon (For tests at or below 400°F)
#120-004 Phenylmethylsiloxane Silicone Fluid, PM-125, 1 gallon (For
tests over 400°F)
#120-00-1 Tool Kit (Includes slurry cup stand, slurry cup tool, lifting
tongs for heater shield, and lifting tongs for potentiometer)
#120-103 Rupture Disk, 45,000 PSI (310 MPa)
#120-201 Thermocouple, Bath
#120-203 Thermocouple, Slurry Cup
#120-35-015 Drip Tray, Stainless Steel
#120-35-033 Air Filter
#120-35-132 Oil Filter
#120-40-753 Backup Ring
#120-40-755 Filter Element for High Pressure Filter
#120-401 O-ring for Cell Cap, Metal
#120-401-V O-ring for Cell Cap, Viton (For tests below 10,000 PSI and
below 300°F only.)
#120-35-031 O-ring for Oil Reservoir, Viton
#120-50-037 Air Regular
#120-521 Slurry Cup with Expansion Chamber
#120-628 Potentiometer Assembly
#120-75-10 Slotted Weight Set
#120-75-9 Weight Hanger
#130-75-28 Allen Key, ", 1¼" Long
#130-77-027-1 Pump
#141-28 Hose Kit
#141-15 Air Hose, 6', Qty: 2
#141-19 Air Hose Adapter, Qty: 6
#141-27 Drain Hose, Stainless Steel
#143-01 Gauge, 0 – 200 PSI
Components

OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ote.com 5
Potentiometer Components:
#120-602 Calibration Spring
#120-603 Potentiometer Body
#120-604 Potentiometer Resistor
#120-605 Contact Spring
#120-606 Potentiometer Contact Arm
#120-607 Contact Strip
#120-608 Grounding Cable Retaining Screw
#120-609 Grounding Contact Spring
Slurry Cup Components:
#120-501 Slurry Cup Sleeve
#120-502 Molded Diaphragm (For tests at or below 400°F)
#120-40-502 Diaphragm (For tests above 400°F)
#120-502-1 Flat Diaphragm, Buna (For tests below 200°F)
#120-503 Paddle Pin
#120-504 Pivot Bearing
#120-505 Pivot Bearing Gasket
#120-506 Paddle
#120-508 Diaphragm Retaining Ring
#120-509 Drive Disk
#120-510 Drive Bar
#120-512 Drive Pin
#120-513 Gasket for Bottom Cap
#120-514 Drive Disk Set Screw, 6-32 × 3, Stainless Steel
Optional:
#120-40-SP Spare Parts Kit
#120-001 Mineral Oil, 1 Gallon, Qty: 2
#120-10-1 Consistometer Tool Kit
#120-103 Rupture Disk, 45-50 KSI, Qty: 2
#120-202 Heater, 4000 Watt
#120-203 Thermocouple, Qty: 2
#120-204 Heaters Gaskets, Qty: 2
#120-401 O-ring for Cell Cap, Metal, Qty: 10
#120-501 Slurry Cup Sleeve
#120-502 Molded Diaphragm, Qty: 25
#120-503 Paddle Pin, Qty: 12
#120-504 Pivot Bearing, Qty: 6
#120-505 Pivot Bearing Gasket, Qty: 5
#120-506 Paddle for Slurry Cup, Qty: 4
#120-508 Diaphragm Retaining Ring, Qty: 2
#120-509 Drive Disk for Slurry Cup
#120-510 Drive Bar for Slurry Cup
#120-511 Shear Pin for Slurry Cup, Qty: 24
#120-512 Drive Pin for Slurry Cup, Qty: 12
#120-513 Gasket for Slurry Cup, Qty: 6
#120-514 Drive Disk Set Screw, Qty: 10
#120-520 Paddle Shaft, 9 ⅛", Qty: 10
#120-521 Slurry Cup with Extension

OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ote.com 6
#120-602 Calibration Spring, Qty: 3
#120-604 Potentiometer Resistor, Qty: 4
#120-606 Potentiometer Contact Arm, Qty: 6
#120-607 Contact Strip, Qty: 6
#120-608 Grounding Cable
#120-684 Bearing, Bronze, Large, Qty: 2
#122-072 Fuse, 1 Amp, 5 mm × 20 mm, Qty: 5
#122-073 Fuse, 2 Amp, 5 mm × 20 mm, Qty: 5
#130-75-28 Allen Key, ", Qty: 2

OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ote.com 7
Safety
Explanation of Symbols
Caution: Risk of Danger - This symbol directs the operator to consult the
instruction manual for safety related warnings. (ISO-7000-0434)
Whenever this symbol is used on the equipment, the user must
consult the manual to determine the nature of the hazard and any
actions which have to be taken.
Hot: This symbol indicates that a surface may be hot to the touch.
Shock Hazard: This symbol indicates a risk of electrical shock.
Note: This symbol will indicate important notes and helpful hints for the
operation of the equipment.
Tip: This symbol is used to identify operational information and best
practices to obtain the most reliable data.
Caution: Note - This symbol is used to indicate statements in the manual
which warn against actions which may cause damage to the equipment
during routine service or maintenance.

OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ote.com 8
• The Consistometer conforms to the relevant safety regulations; however
the user is solely responsible for the correct handling and proper usage of
the instrument.
• The equipment should be operated in such a way that will not endanger
people.
• The equipment must not be operated if there is any evidence of external
damage, leading to any doubt regarding safe operation.
• The user must comply with the instructions in this instruction manual,
otherwise safe operation cannot be guaranteed.
• This instruction manual must be readily available for all operators.
• Do not bend or stress connection cables and mains cable.
• Do not subject connection or mains cables to high temperatures (higher
than 70°C).
• Check integrity of cables at regular intervals.
• The unit must be powered down before any cables are connected or
disconnected. This reduces the risk of electrostatic charging and resultant
damage to electronic circuit boards.
• The operator must have a good familiarity with the installation of the unit
and its surroundings.
• Suitable protective gear should be worn in the factory environment in
which the unit has been installed.
• The unit should be serviced at regular intervals as detailed on page 40.
• The user is responsible for the safe handling of any materials tested. If in
doubt the material safety data sheet should be read, relevant safe han-
dling regulations should be read and observed and good operating and
manufacturing practices should be followed.

OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ote.com 9
Quick Start
Starting a Test
1. Before turning on the Consistometer, make sure the MOTOR, HEAT,
COOLING, PUMP, and FILL/DRAIN CELL switches are all o.
2. Turn the MAIN POWER switch on.
3. Turn the MOTOR switch to ON.
4. Slowly lower the slurry cup into the test cell until the drive table engages
with the drive pins on the bottom.
5. Lower the potentiometer into the test cell so that it sits on top of the slurry
cup.
6. Turn the MOTOR switch to AUTO.
7. Carefully lower the cell cap into the test cell and tighten it.
If you are using a metal o-ring and you tighten the cell cap past the
marked position, you must use a new o-ring for the next test.
8. Plug the thermocouple into the port near the test cell. Insert the
thermocouple into the hole in the top of the cell cap and tighten the thread
gland nger tight and loosen it ¼ of a turn.
9. Close the pressure release valve by turning it clockwise.
10. Turn the FILL/DRAIN CELL switch to FILL. When the cell is full, oil will
leak out of the thermocouple tting on the cell cap. Tighten the tting to
seal the cell.
Leave the FILL/DRAIN CELL switch in the FILL position during
testing.
11. Turn the HEAT, COOLING, PUMP, and POT VOLTS switches to AUTO.
12. Turn the DAQ PAUSE switch to OPERATE and the ALARM swtich to ON.
13. Load the test:
a. If you will be using the software to run the test, select a Test Prole
and click the Start Test button on the Main Screen (see page 21).
b. If you will be using the onboard controls to run the test, rst select a
test to run (see page 29), then touch the Start Test button.
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali OfiTE Strumento di misura

OfiTE
OfiTE 175-65 Manuale utente

OfiTE
OfiTE HTHP 100 Manuale utente

OfiTE
OfiTE HTHP Manuale utente

OfiTE
OfiTE 4005 Manuale utente

OfiTE
OfiTE 130-85 Manuale utente

OfiTE
OfiTE 900 Manuale utente

OfiTE
OfiTE 150-80 Manuale utente

OfiTE
OfiTE 131-50 Manuale utente

OfiTE
OfiTE 2025 Manuale utente

OfiTE
OfiTE 120-53 Manuale utente