Reed Instruments R2320 Manuale utente

www.REEDINSTRUMENTS.com
Infrared
Thermometer
Instruction
Manual
R2320
REED Instruments

2
www.REEDINSTRUMENTS.com
Table of Contents
Introduction ................................................................................................... 3
Product Quality.............................................................................................. 3
Safety ............................................................................................................ 3
Features......................................................................................................... 4
Included......................................................................................................... 4
Specications.............................................................................................4-5
Instrument Description .................................................................................. 6
Display Description ....................................................................................... 7
Distance & Spot Size..................................................................................... 8
Operating Instructions..............................................................................9-13
Power ON and OFF .................................................................................. 9
Manual Measurement............................................................................... 9
Continuous Temperature Measurement (Trigger Lock) ............................ 9
Maximum, Minimum, Average and Differential Functions ...................... 10
Turning Laser On/Off .............................................................................. 10
Setting the High Temperature Alarm ...................................................... 11
Setting the Low Temperature Alarm....................................................... 11
Adjusting Emissivity................................................................................ 12
Switching the Unit of Measure (°F/°C).................................................... 12
Audible Alarm Setting............................................................................. 13
Trigger Lock Setup ................................................................................. 13
Turning High and Low Alarms ON/OFF .............................................13-14
Fault Diagnostics......................................................................................... 15
Battery Replacement................................................................................... 16
Applications................................................................................................. 16
Appendix: Emissivity Chart ....................................................................16-18
Product Care ............................................................................................... 18
Product Warranty ........................................................................................ 19
Product Disposal and Recycling ................................................................. 19
Product Support.......................................................................................... 19
REED Instruments

3
www.REEDINSTRUMENTS.com
Introduction
Thank you for purchasing your REED R2320 Infrared Thermometer. Please
read the following instructions carefully before using your instrument. By
following the steps outlined in this manual your meter will provide years of
reliable service.
Product Quality
This product has been manufactured in an ISO9001 facility and has been
calibrated during the manufacturing process to meet stated product
specications. If a certicate of calibration is required please contact the
nearest authorized REED distributor or authorized Service Center. Please
note an additional fee for this service will apply.
Safety
• Neverattempttorepairormodifyyour
instrument. Dismantling your product,
other than for the purpose of replacing
batteries, may cause damage that will
not be covered under the manufacturer's
warranty. Servicing should only be
provided by an authorized service center.
• Useextremecautionwhenthelaserbeam
is turned on.
• Donotletthebeamenteryoureye,anotherperson'seyeortheeyeof
an animal.
• Becarefulnottopointthebeamoffareectivesurfaceandstrikeyoureye.
• Donotallowthelaserlightbeamtoimpingeonanygaswhichcanexplode.
REED Instruments

4
www.REEDINSTRUMENTS.com
Features
• Built-inlaserpointeridentiestargetarea
• Userselectable°For°C
• 30:1DistancetoSpotsizeratio
• Brightcolordisplay(EBTN)
• Digitallyadjustableemissivity
• Max,Min,AverageandDifferentialreadings
• Audible(beep)andvisual(tri-colorLED)useradjustablealarms
• Internalmemorystoresupto5pre-sethigh&lowalarmsand5
emissivity settings
• Triggerlockandtripodmountforcontinuousmonitoring
• Lowbatteryindicationandautoshutoff
Included
• Carrying Case
• Battery
Specifications
TemperatureRange: -26to1472°F(-32to800°C)
Accuracy: Basic:±1.8%ofreadingor3.6°F(1.8°C)
Detailed:≥0°C:±1.8°Corofreading
±1.8%°Cwhicheverisgreater
<0°C:±(1.8°C+0.1°C/°C)
≥32°F:±3.6°F or of reading ±1.8%,
whichever is greater, <32°F:±(3.6°F+0.1°F/°F)
Resolution: 0.1°F(0.1°C)
OpticalResolution(D:S): 30:1
Repeatability: 0.7°Cor0.7%,whicheverisgreater
(1.5°For0.7%,whicheverisgreater)
Spectral Response: 8 to 14µm
continued...
REED Instruments

5
www.REEDINSTRUMENTS.com
Emissivity: 0.1to1.0(Adjustable)
Response Time: 250ms
BacklitDisplay: Yes(ColorEBTN)
Display Hold: Yes
High/LowAlarms: Yes(audibleandvisual)
AlarmIndicators: LED(High:Red,Low:Blue)
Max/Min: Yes
Average and Differential: Yes
F/CSwitchable: Yes
TriggerLock: Yes
TripodMountable: Yes
LaserClass: ClassII
LowBatteryIndicator: Yes
Power Supply: 9V Battery
BatteryLife: Approx.10hours
(withcontinuoususe,backlighton)
Product Certications: CE, RoHS
OperatingTemperature: 32to122°F(0to50°C)
StorageTemperature: -4to140°F(-20to60°C)
Operating Humidity Range: 10 to 90%
MaximumOperatingAltitude: 6561'(2000m)
MaximumStorageAltitude: 39370'(12000m)
Dimensions: 7x4.98x2"(179×126.5×53mm)
Weight: 10.95oz(310g)
REED Instruments

6
www.REEDINSTRUMENTS.com
Instrument Description
1. LaserPointerBeam
2. IR Sensor
3. Trigger
4. Battery Cover
5. TripodMount
6. LCDDisplay
7. ModeButton/DownArrow
8. Set Button
9. High/LowAlarmButton/
UpArrow
10.LaserON/OFFButton
-26~1472°F / -32~800°C
D:S=30:1
1.2@36
0.9@12
2.5@60
30@900
24@300
62@1500
R2320
Professional
Infrared Thermometer
www.REEDINSTRUMENTS.com
REED Instruments

7
www.REEDINSTRUMENTS.com
Display Description
TemperatureMeasurementTriggerLock
Audible Alarm Indicator
TemperatureMeasurementAlarmIndicator
LowBattery
TemperatureMeasurementActive
MeasurementDataHold
UnitofMeasurement
TemperatureMeasurementValue
TemperatureMeasurementValuefromSelectedMode
Emissivity
LaserOn
Mode
K
K
REED Instruments

8
www.REEDINSTRUMENTS.com
Distance & Spot Size
4
REED Instruments

9
www.REEDINSTRUMENTS.com
Operating Instructions
Power ON and OFF
1. Gentlypullthetriggertoturnthethermometeron.TheLCD
display and the backlight will turn on.
2. The thermometer will automatically shut off after 15 seconds
of inactivity.
Manual Measurement
1. Pull and hold the trigger after aiming at the target. The icon
willash,indicatingthatthetargettemperatureisbeingmeasured.
2. When the trigger is released, the icon will disappear and the
icon will appear indicating that measurement has stopped
and the last measured temperature will remain on-screen until
another measurement is taken or the unit turns off.
Continuous Temperature Measurement (Trigger Lock)
T
he instrument allows for a continuous temperature measurement time to
be set from 1 minute to 5 hours. Refer to Trigger Lock Setup for details.
Note: This function is applicable for processes that require regular moni-
toring of temperature.
1. Once the trigger lock function is enabled, the icon will appear on
thedisplayandtheSCANiconwillashwhenthetriggerispressed.
2. Pull the trigger again to stop measuring and both the andSCAN
iconswilldisappearandtheHOLDiconwillappear.Thethermometer
will now hold the last measured value until the unit turns off after 15
seconds of inactivity or until testing is resumed.
3. When the continuous temperature measurement time is reached, the
thermometer will automatically power off and save the last measured
value. You can view the last measured value by pulling the trigger.
Note: The last measured value is cleared when a new test scan is started.
continued...
REED Instruments

10
www.REEDINSTRUMENTS.com
Maximum, Minimum, Average and Differential Functions
Press the MODEbuttontotogglebetweenMAX/MIN/AVG/DIFmodes.
The temperature value of corresponding modes are shown in the
secondary display area.
Turning Laser On/Off
Press the buttontoturnthelaserindicatorfunctionONandOFF.
Whenitisturnedon,thelaserindicatorwillbedisplayedontheLCD,
while the red laser beam will indicate the position you are measuring
during testing.
continued...
REED Instruments
Indice
Altri manuali Reed Instruments Termometro

Reed Instruments
Reed Instruments R2330-NIST Manuale utente

Reed Instruments
Reed Instruments C-370 Manuale utente

Reed Instruments
Reed Instruments R2450SD Manuale utente

Reed Instruments
Reed Instruments R2400 Manuale utente

Reed Instruments
Reed Instruments R2340 Manuale utente

Reed Instruments
Reed Instruments FS-200 Manuale utente

Reed Instruments
Reed Instruments Smart Series Manuale utente

Reed Instruments
Reed Instruments SMART Series Manuale utente

Reed Instruments
Reed Instruments R2330 Manuale utente

Reed Instruments
Reed Instruments R2000 Manuale utente