RF SOLUTIONS MAINSLINK Manuale utente

MAINSLINK
DS-MAINSLINK-9PATENT No 2564512
230Vac Radio Link
The Original Pump Overrun Solution
Part Number Description
MAINSLINK System (TX and RX) ready to go
Features:
• Supplied ready to operate
• Replaces a “Switched Live Cable”
• Quick and Simple to Install
• Up to 5Km range line of sight.
• Up to 1Km range in buildings
• Screw Terminal Connections
• 110Vac or 230Vac Operation
• FSK/LoRa Spread Spectrum RF
Modulation
• Weatherproof IP68 Enclosures
• RED Compliant and FCC Certified
• High Quality UK manufacture
Description
MAINSLINK is a plug and play solution to replace a switched live cable. When 230Vac
“LIVE” is input to the transmitter, the receiver provides a 230Vac “LIVE” switched
output at its screw terminals.
MAINSLINK utilises the RF Solutions state of the art RF-LoRa Spread Spectrum Fre-
quency Modulation transceiver design to achieve a the highest performance / Range
available from any Radio System, upto 1Km within a building environment and 5Km Line
of sight.
When used as a Pump Overrun solution the TX is placed by the boiler and connected to
the Boiler Pump output. The RX directly drives the pump from its Live switched output
Ordering Information

MAINSLINK
DS-MAINSLINK-9
PATENT No 2564512
N L
Switched
SUPPLY
WDOG
MODE
MOM/LAT
TX
Installation
SWITCHING
LIVE OUT
N E N L
Permanent
LIVE Supply
Not Used
PERMANANT
SUPPLY
Lout (LIVE OUT)
WDOG
MODE
MOM/LAT
RX
Connect the Switched Input Lin
Connect the Switching Live input to Lin.
When this input is ’LIVE’ the Red LED will illuminate, and MAINSLINK-RX will then switch
Live out at its output
Connect
1. Permanent LIVE and NEUTRAL supply.
2. Your Load to Switching Lout
When the Live Output (LOUT) is LIVE the Red LED will illuminate
Indicates that
input is LIVE
Flashes when RF
Transmitting
Flashes when
RF Active
(also indicates
error mode)
Indicates that
output is LIVE

MAINSLINK
DS-MAINSLINK-9
PATENT No 2564512
Warnings :
• Product is not independently isolated, ISOLATE the mains electricity supply before re-
moving the cover and observe any relevant safety precautions. Maintenance to the
product that involves removal of the cover should only be carried out by a competent
person or qualified electrician.
• F2 Fuse rating is 4A (T) 250 H (Ceramic). Replace fuse with same type and rating.
• Relay is rated at 10A peak, and 5A constant.
• Product must be connected to a switch fused (spur/supply) or BS 1363 Plug. It is rec-
ommended a single Fuse Spur is used to supply the Boiler and MAINSLINK-PRO jointly so
that they are isolated together.
Application example: WORCESTER-BOSCH Boiler Installation
Operation
When the Boiler switches the Pump ON, MAINSLINK-TX is
switched Live, then, MAINSLINK-RX Lout will automatically
switch the pump on.
Switching Lower Power LED Lights
Mainslink-RX incorporates a “snubber” protection circuit
which is recommended with Load connections such as a
Motor or pump.
If switching lower power LED lighting the snubber circuit can
cause the LED lights to faintly glow when switched off.
To remove the snubber, remove Jumper link J2 on the rear
of the PCB (as image shows).

MAINSLINK
Disclaimer:
Whilst the information in this document is believed to be correct at the time of issue, RF Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or completeness.
No express or implied warranty or representation is given relating to the information contained in this document. RF Solutions Ltd reserves the right to make changes and improvements to
the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such information or products for their own particular require-
ments or specification(s). RF Solutions Ltd shall not be liable for any loss or damage caused as a result of user’s own determination of how to deploy or use R F Solutions Ltd’s products.
Use of RF Solutions Ltd products or components in life support and/or safety applications is not authorised except with express written approval. No licences are created, implicitly or
otherwise, under any of RF Solutions Ltd’s intellectual property rights. Liability for loss or damage resulting or caused by reliance on the information contained herein or from the use of the
product (including liability resulting from
negligence or where RF Solutions Ltd was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict QuasarUK Ltd’s liability for death or
personal injury resulting from its negligence.
Important European compliance information
This RF Solutions product meets the essential requirements of the European Radio Equipment Directive
2014/53/EU and has been tested to European Harmonised Standards and CE marked accordingly. A
copy of the EU Declaration of Conformity can be located on the RF Solutions Website,
www.rfsolutions.co.uk/certification-i59.
RF Solutions Ltd. Recycling Notice
Meets the following EC Directives:
DO NOT
Discard with normal waste, please recycle.
ROHS Directive 2011/65/EU
Specifies certain limits for hazardous substances.
WEEE Directive 2012/19/EU
Waste electrical & electronic equipment. This product must be disposed of through a licensed WEEE collection point. RF Solutions Ltd., fulfils its
WEEE obligations by membership of an approved compliance scheme, environment agency registration number WEE/JB104WV.
Jumper Link Setting
There are three Jumper Links which may be used to configure the following
Link Open Fitted
WDOG Watchdog OFF Watchdog Active
MODE FM LORA Mode 3
MOM/LAT Momentary Latching
WDOG
MODE
MOM/LAT
WDOG - WATCHDOG
This provides improved reliability and security, useful with electrically noisy Loads.
When the WDOG link is fitted each MAINSLINK automatically sends a background watchdog RF signal
and expects to receive a corresponding WDOG signal from its partner.
If the WDOG signal is not received within 90 seconds, the output will drop out and comms LED will
flash.
MODE
FM: Fast operation shorter range (Line of sight upto 500m/100m in buildings)
This mode is recommended for general operation.
LORA Mode 3: Slower operation Long range (Line of sight upto 5Km/1Km in buildings)
This mode can be used where additional RF penetration / range is required.
NOTE: In this mode a transmitted signal can take 2 seconds to trigger the receiver.
MOM/LAT - Momentary or Latching Output
Sets the Relay changeover contacts to operate as Momentary or Latching.
MOMENATRY: Used for MAINSLINK TO MAINSLINK.
LATCHING: Select this when MAINSLINN-RX is controlled by a Remote transmitter - e.g. pocket keyfob.

MAINSLINK
DS-MAINSLINK-9
PATENT No 2564512
1. Apply a 230Vac supply to the MAINSLINK-RX
2. Briefly swipe a magnet along left side as shown
3. The GREEN comms LED will flash 3 times to show “in Pairing Mode”
Erasing a MAINSLINK-RX
1. Apply a 230Vac supply to the MAINSLINK-TX
2. Briefly swipe a magnet along left side as shown
3. MAINSLINK-TX will now send a special Pairing message
4. The MAINSLINK-TX and MAINSLINK-RX will now Auto pair together
- allow 15 secs.
To erase the system hold a magnet beside the top left side
of the enclosure until the Green COMS LED is ON solid
(about 5 seconds).
Technical Specification:
Dimensions: 92 x 92 x 59mm
Electrical Characteristics Min Typical Max Units
Supply Voltage TX/RX: 100 230 250 Vac
Operating Frequency* 869.50 MHz
RF Output power +20 dBm
Bandwidth (Spreading Factor) 60 KHz
Maximum switching load (RX) 1000 W
Time delay from TX Transmit to RX Relay
operation:
Mode FM
Mode 3
0.02
2
Secs
Advanced Operation Pairing a MAINSLINK-TX to a MAINSLINK-RX
NOTE: This system does not require pairing, they are supplied ready to operate!
This process is described for advanced use only.
MAINSLINK-RX COMMS LED
Operation
2 x Flashes 3 x Flashes
Status Unpaired In Pairing Mode

MAINSLINK
DS-MAINSLINK-9
PATENT No 2564512
Product Revision History
The below shows the product Development / Improvements that have been made to the
product through the product Lifecycle
MAINSLINK REVISION CHANGE HISTORY
Date Eng
Change Product Change / Improvement
New
Revision
18/10/18 ECN314
Update to firmware to prevent lockup when pairing in Mode 3.
Using Mode 3 only, the length of RF packet is >2secs, if, when in LEARN mode
both MAINSLINKS’ transmit at the same time then they can both be in the
position of waiting for a response.
New F/W randomly sets one as master on initial RF signal, then only one re-
sponse is received removing the RF competition.
2
12/2/19 ECN319 6
If the input (RX signal) immediately coincides with an output (TX signal) in very
rare cases (two reported) the RF transceiver has locked up, this is a fix to this
issue.
1/9/19 ECN331 8 Addition of LEDs on Front panel for visual indication or operation. Improvements
to the enclosure.
Version Identification
The product part number and revision of build can be viewed on the white label on the outside of the enclosure and
also on the Circuit board assembly.
Indice
Altri manuali RF SOLUTIONS Sistema di controllo

RF SOLUTIONS
RF SOLUTIONS MAINSSWITCH-8SL1 Manuale utente

RF SOLUTIONS
RF SOLUTIONS ESPRIT LOW VOLTAGE Series Manuale utente

RF SOLUTIONS
RF SOLUTIONS Hornet-S2 Manuale utente

RF SOLUTIONS
RF SOLUTIONS PRO-CARLTON Manuale utente

RF SOLUTIONS
RF SOLUTIONS FOBLOQ Series Manuale utente

RF SOLUTIONS
RF SOLUTIONS MAINSLINK-PRO Manuale utente

RF SOLUTIONS
RF SOLUTIONS ELITE-RXL Manuale utente

RF SOLUTIONS
RF SOLUTIONS ELITE-L Series Manuale utente

RF SOLUTIONS
RF SOLUTIONS MAINSSWITCH-8SL1 Manuale utente

RF SOLUTIONS
RF SOLUTIONS HORNET200 Manuale utente