SBS SBS-600 Manuale utente

SBS-600/700 Quick Start Guide Revision 1.0 -5/2014
1
SBS -600 Graphical Digital Multimeter
SBS- 700 Multi-Function Oscilloscope
Quick Start Guide
Quick start guide will explain basic information about the unit.
For complete Operation and Safety Information, Please refer to the
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

2
User Manual supplied on the CD-Rom included with the Quick start guide.
“READ THE USERS MANUAL PRIOR TO OPERATION”
"Pay special attention to the SAFETY Information sections of the Quick start
guide and the user’s manual”
Attention
Attention mark is displayed to draw ATTENTION during use. Meter could be damaged or
important Data may be lost if the unit is used improperly.
Warning
Warning mark is displayed to indicate improper use. Operating outside of equipment ratings
could cause serious personal injury or fatal death.
[Safety Symbol]
Table lists and describes the safety symbols shown on Meter or in User Manual.
: DC (Direct Current or Voltage)
: AC (Alternating Current or Voltage)
: DC and AC
: Earth Ground
: Double Insulation
: Power Supply OFF
: Power Supply ON
: Warning of Electric Shock
: Warning of Danger
: CategoryⅡ 1000V Overload Protection(Multi-meter Function :Model SBS-600
SBS-700 )
: CategoryⅢ 600V Overload Protection(Multi-meter Function
Model SBS-600, SBS-700)
: CategoryⅢ 300V Overload Protection(Scope Function, Model . SBS-700)
:
[Notes for Safe Operation]
WARNING: USE EXTREME CAUTION IN THE USE OF METER
The improper use of meter may result in injury or death.
Follow all safeguards in this manual, in addition to the normal safety precautions used in
working with live electrical circuits.
DO NOT ATTEMPT TO SERVICE the meter if you are not qualified to do so.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com

3
[WARNING ]
Pay attention when testing conditions exceed 60V DC, 30V AC rms or 42.4V AC Peak that can
cause an electric shock. Do not connect the Ground wire to voltage higher than 0V DC, 30V
AC rms or 42.4V AC Peak.
Use only the proper accessories supplied with the meter. Rechargeable Battery Pack, AC
Power Adapter and Internal Charger, Test Lead, Probe, Logic/Signal Cable set. Warranty
will not cover Meter Measurement failure or damage from improper accessories other than
supplied by manufacturer of the Meter.
Connect and disconnect properly. Connect Test Leads, Probes or Cables to the Meter before
connecting to the active circuit to be tested. Disconnect Leads, Probes or Cables from the test
circuit prior to disconnecting them from the meter.
Testing Probe always connected with Testing Circuit in series.
Replace the Ni-MH Battery Pack only with an equivalent from the Manufacturer. Remove
AC Power Adapter, Test Lead, Probe and Cable from Meter when replace the Battery.
When the Battery Warning Symbol is blinking on the display, the measurement may display
in error. Recharge the battery or replace.
Observe all terminal ratings. Observe all rating and marking oin the Meter. Refer to
Operator manual for detailed information.
[ Max Input Voltages]
- Scope Input: 300V CATⅢ.
- Meter Input: 600V CATⅢ.
Do not apply any voltages when measuring OHM (resistance) or Capacitance for the Meter
Mode.
Do not use Meter where in or near explosive, flammable, wet or damp environments.
Do not use Meter with the Case Cover open for any reason.
Fuses should only be replaced with the proper size and rating as specified in the manual.
Do not expose circuit.
[ATTENTION]
Before testing in Resistance, Capacitance, Continuity or Diode modes, disconnect any
power supply to the circuit being tested and discharge High Voltage Rated Capacitance.
Do not attempt Voltage measurement while measuring Current.
[ENVIRONMENT]
The Meter is designed Indoor use in following environment conditions
Operating Temperature: 32°F - 122°F (0°C ~ 50°C)
Guaranteed Accuracy Temperature: 73.4°F +/- 41°F (23 0°C +/- 5°C)
Operating Humidity: 80% R.H. or less
Storage Temperature: 32°F - 158°F (0°C ~ 70°C)
Altitude : 2000m
CAT III 600V Pollution Degree : 2

5
SBS - 600 SBS - 700
Function and Menu selections automatically take effect 2 seconds after
pressing the key.
If the user Prefers immediate setting Pressing the ENTER key will
immediately select the Function or Menu.
Voltage measurement keys : AC+DC, DC, AC
Current measurement keys : AC+DC, DC, AC
Resistance, Continuity, Diode Check key
Capacitance measurement key
Auxiliary measurements (Temperature, Relative Humidity, Hi-Currents.
Pressure) with use of optional accessories not included.
Square wave signal out put
Oscilloscope
Protocol Analyzer
Pattern Generator
Logic Analyzer

6
[Secondary Function Key]
[ Secondary Function Keys ]
Function key
Function Description
Selects Sub Menu functions and modes after (main) Menu selection.
Upper Line: (Short Key) One Touch press Enter Menu (Main Menu)
functions and modes. Lower Line: (Long key) Press longer than 2
seconds to enter USER. To return to Menu, press Exit key
Upper Line : Meter setup Auto Ranging mode
Lower Line : (Long key) Press longer than 2 seconds to enter Manual
measurement mode (Range)
- In Manual Range, range up/down can be selected with a Short key
press (One touch)
- To return to Auto measurement mode, hold key down (longer than 2
seconds)
Upper Line: (Short Key) One Touch press enter Data Logger mode.
Lower Line: (Long key) Hold longer than 2 seconds to enter Save
(Data) and Recall (Data) mode. Save or Recall selection change
available at sub-mode.
- Press Short Key to change Logger Mode.
- Press F4 Exit to leave Logger mode.
Upper Line (Manual Hold): (Short Key) One touch press to enter
Hold/Run mode. Hold the present measurement value in Display and
can save the value. Change Hold or Run can be done (Short Key)
One Touch press.
Lower Line (Automatic Hold) : (Long key) Hold longer than 2 seconds
to enter Auto Hold mode.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com

7
LCD Display
Scope Screen
No
Symbol
Description
1
RUN
Present measurement is proceeding and working.
2
HOLD
Measurement is being held momentarily
3
V/div
Volt (Vertical Axis) Division indicator
4
T/div
Time (Horizontal Axis) Division indicator
5
Trigger
Trigger indicator for Level, Position or Edge direction
6
Coupling
Input Coupling selection (DC/AC)
7
Peak
Peak Detection selection (ON/OFF)
8
V/Position
Volt (Vertical Axis) Position adjustment
9
T/Position
Time (Horizontal Axis) Position adjustment
10
Trig Level
Trigger Level adjustment
I (Help): (Short Key) One Touch press to enter Help mode. Brief
Information on present function is displayed.
Back Light On/Off: Hold longer than 2 seconds to enter Back Light
display mode.
Help: short key(50ms), Backlight: long key(2s)
Turn the meter power ON / OFF
Hold Longer than 2 seconds to power ON / OFF
Cursor buttons select an item in Menu. Adjust Display Ratio. Scroll the
information and Input Data

8
DMM Screen
No
symbol
Description
1
Minimum. Maximum, Average measurement
2
Can select Measuring Range in Automatic method or Manual
method
3
Freeze the present reading in display.
4
Freeze the present reading in display.
5
Sub Menu
The Subsidiary Menu. After main menu selected, sub menu tree
show up to select
6
Bar-Graph
Input Signal is displayed in Bar-Graph. refer details " Bar-Graph
page )
7
Compare with a reference value and display the Difference.
8
Negative Reading
9
Input Over Voltage warning that exceeds the defined safety
protection voltage
10
Remaining Battery Capacity level to use.
11
Being connected with AC Power Adapter.
12
Sampling, Run time
13
Measurement mode.(DCV, ACV, Ohm, Capacitance, Diode)
14
Audible signal is active
15
(Bar Scale)
Range of Meter
16
Secondary
measurement
secondary measurement information of Input Signal (Hz. ㏈m)
17
Unit symbol is displayed at right side of the measurement

9
Data Logger Screen
No
Symbol
Description
1
Measuring Mode. (DCV, ACV, Ohm, Capacitance, Diode)
2
RUN and STOP of Data Logger function
3
Run Time
4
Accumulated Sample Q‘ty in Data Logger.
5
Maximum Display Range
6
Minimum, Maximum , Average of the Samples
7
Total Time Scale of Data Logging.
8
Present Measurement Value
9
Change the Time Scale (left - right horizontal axis) to review
closely on the specific Time Zone.
10
Zoom (at Regular Ratio) the specific waveform quickly (up/ down
Vertical axis).
11
Data Logger
Data Logger Display

10
Logic Analyzer Screen Protocol Analyzer Screen
[Logic Analyzer, Protocol Analyzer Display Symbol]
No
Symbol
Description
1
Condition
Logic Analyzer: Pattern, Duration
Protocol Analyzer:
CAN, LIN, I2C, UART, USB, I2S SMBus, SPI, DMX512, 1-Wire
2
Time/div
Measurement Time/div Indicator
3
Channels
Displays all the Input Channels
4
Horizontal
Time Division & Position adjustment
5
Trigger
Trigger Mode, Source, and Trigger Level adjustment
6
Cursor
Horizontal Cursor adjustment
7
Condition
Detailed condition setting for each Logic or Protocol type
8
Information
Display window to show the trigger condition or channel input
information of each type
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali SBS Strumento di misura

SBS
SBS 3500 Manuale utente

SBS
SBS SBS-2510 Manuale utente

SBS
SBS SBS-6500 Manuale utente

SBS
SBS SBS-2510 Manuale utente

SBS
SBS SBS-2500 Manuale utente

SBS
SBS SBS-3510 Istruzioni originali

SBS
SBS SBS-2500 Manuale utente

SBS
SBS SBS-2510 Manuale utente

SBS
SBS SBS-3500 Manuale utente

SBS
SBS SBS-2500 Manuale di programmazione