TYPEL PLUS OperatingInstructions
7
4.0 ElectricalSpecifications
Display3.5 digit LCD 12mm high characters
Measurement range 0 2000 Amps
Accuracy ±3% ±1digits f.s.d. onall ranges,
with conductor positioned centre of
jaws.
Voltage 50 600 volts AC 50 Hz
Operating Temperature 0 ºC to +40 ºC
Storage Temperature -20 ºC to +50 ºC
Battery9VDC Alkaline MN1604 6LR61
5.0 Operation
5.1 Track Mode
5.1.1 Press and release the Trackbutton on the Type LPlus
control panel. The LCDdisplaywill indicatethree
zeroes, signifying no current flowdetected. If the BAT
symbol appears in the top left corner of the LCDdisplay
then the battery within the unit must be replaced (see
section 6).
5.1.2 Operate thetrigger mechanismon the Type LPlus
handle to pivot open the jawsof the instrument and
insert the conductor to be tested within them.
It isnot necessaryfor the jawsof aTypeLPlus
current clamp meterto becompletely closed,
however formaximum accuracythe tips of the jaws
should be in contact with one another.
For maximum accuracy,the conductor under test
shouldbe positioned inthe centreof the internaljaw
area.
5.1.3 The AC current flowing throughthe conductor is
recordedon the LCD displayand is continuously
updated to reflect any changes in theconductor current.
If the batterysymbolisvisibleonthe LCD display
then the current reading must be assumed to be
incorrectsince the batteryrequires replacing.