Sigma Metalytics PMV Pro PRO Manuale utente

ERIFIER
Precious Metal
PRO
MANUAL
MODEL #2601

2
Contents
Caution ..................................................................................................................................3
PMV PRO Diagram ............................................................................................................4
PMV PRO Functions .........................................................................................................5
Power On and Calibrate .................................................................................................6
Setup ......................................................................................................................................7
Metal Selection ...................................................................................................................8
Weight Entry .......................................................................................................................9
Measurement Screen ....................................................................................................10
Measurement Interpretation ....................................................................................11
Wand Use ...........................................................................................................................14
PC Interface ......................................................................................................................15
External Bridge Use ......................................................................................................16
Thickness Calibration ..................................................................................................18

3
CAUTION
Read Before Use
• The onboard sensors and bridges are very sensitive to stress. DO
NOT press on them, place objects on them, or lift the device by the
bridges. Stress can cause miscalibration and damage.
• The plastic cover on the display protects the screen from damage.
DO NOT remove the plastic cover from the display.
consistent with the selected metal or alloy, are INFORMATIONAL ONLY and any judgment about or action taken with regard to any
sample is entirely the responsibility of the user. To ensure accuracy, thoroughly read the included instructions and be aware of the
special conditions which may affect the readings.

Power
CalMetal MeasureWeight
[█]
10 mm05 51 02 52 03 53 04 54 05 55 06 56 07 57 08 105 11058 09 59 001 511 021 521 031 531 140
Place sample against dotted lines where indicated.
Precious Metal
Firmware Version: 1.01
FPGA Version: 1.03
Database: 1.03
Small Sensor
and Bridge
Large Sensor
and Bridge
Sample Placement
Circle
Active Sensor
Lamps
Dimensions
Lamps
Measurement
Scale
Sample Placement
Circle
Sample must cover inside
of placement circle
External
Bridge
Connector
Wand
Connector
Power
Connection
PMV Pro
Sample must cover inside
of placement circle
4
Enter
Button

5
PMV PRO Functions
The PMV PRO uses up to four different measurements to determine if a coin or bar is
consistent with genuine precious metals.
The four measurements are:
1. The PMV PRO measures the sample’s resistivity just under
the surface of the metal. This ensures there are no contaminants or foreign metals in
or near the surface.
2. Using the sensors above and below the sample, the PMV PRO measures
the sample’s bulk resistivity. This measurement checks the entirety of the sample
and ensures there are no contaminants or foreign metals anywhere between the two
sensors.
3. The PMV PRO electronically measures the thickness of the
sample using the average thickness of the face of the sample.
4.
the sample is the correct density. The user must enter the measured weight of the
sample to perform this test.

6
Firmware Version: 1.01
FPGA Version: 1.03
Database: 1.03
Power On and Calibrate
Power on your PMV PRO by pressing the POWER button. The device will display the serial number,
turned on. This calibration checks the internal components and prepares the device for use. Press the
CAL button to calibrate. The device will check each sensor then show the READY screen.

7
Setup
You may change some settings in the SETUP screen. To access the SETUP screen, press the RIGHT
button on the READY screen. Use the UP and DOWN buttons to select the category, and use the RIGHT
and LEFT buttons to change the selection within a category. Press the ENTER button when done to exit
the SETUP screen.
Note: You do not need to setup the device each time you use it, the settings are saved between uses.

8
Metal Selection
Prior to taking a measurement, you must select the appropriate metal or alloy from the metal selection
database. Press the button open the selection menu. Use the LEFT and RIGHT buttons to
navigate between metal categories, and use the UP and DOWN
a category. When ready, press the ENTER, , or WEIGHT

9
Weight Entry
To enter the weight of a sample, press the WEIGHT button. You can either select from the options listed
in the English Units (Ozt) and Metric Units (grams) categories, or you can manually enter a weight on
your own. Use the LEFT and RIGHT buttons to navigate between categories, and use the UP and DOWN
buttons to select options within a category. When ready, press ENTER, , or
the selection.
Manual Weight Entry
To manually enter weight, use the UP and DOWN
buttons to select the type of weight you want to enter.
Press the ENTER button to change the indicated
weight. Use the LEFT and RIGHT buttons to select the
digit and use the UP and DOWN buttons to change
the digit value. Press the or button

10
Sample consistent with
selected metal
aspects of sample, like
size, weight, and
markings.
Sample inconsistent
with selected metal
Measurement Screen
The MEASUREMENT screen will display when taking a reading. Below is a basic explanation of each
part of the screen. The screen will not display the diameter, thickness, or weight if weight mode is
Indicates the device is getting a
reliable reading.
Indicates the device is getting an
unreliable reading, treat result
with caution.
Indicates the result is off the
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Sigma Metalytics Strumento di misura

Sigma Metalytics
Sigma Metalytics Precious Metal Verifier Manuale utente

Sigma Metalytics
Sigma Metalytics VERIFIER PMV PRO Mini Manuale utente

Sigma Metalytics
Sigma Metalytics Precious Metal Verifier PRO 2601 Manuale utente

Sigma Metalytics
Sigma Metalytics Precious Metal Verifier INVESTOR 3012 Manuale utente