TeeJet Technologies DynaJet Flex Series Manuale utente

DYNAJET® FLEX
INSTALLATION, SETUP AND USER GUIDE
Software version 1.02
with optional high ow option

Copyrights
© 2016 TeeJet Technologies. All rights reserved. No part of this document or the computer programs described in it may be reproduced, copied, photocopied, translated, or
reduced in any form or by any means, electronic or machine readable, recording or otherwise, without prior written consent from TeeJet Technologies.
Trademarks
Unless otherwise noted, all other brand or product names are trademarks or registered trademarks of their respective companies or organizations.
Limitation of Liability
TEEJET TECHNOLOGIES PROVIDES THIS MATERIAL “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED. NO COPYRIGHT LIABILITY
OR PATENT IS ASSUMED. IN NO EVENT SHALL TEEJET TECHNOLOGIES BE LIABLE FOR ANY LOSS OF BUSINESS, LOSS OF PROFIT, LOSS OF USE OR DATA,
INTERRUPTION OF BUSINESS, OR FOR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY KIND, EVEN IF TEEJET TECHNOLOGIES HAS
BEEN ADVISED OF SUCH DAMAGES ARISING FROM TEEJET TECHNOLOGIES SOFTWARE.

Table of Contents
DYNAJET® FLEX OVERVIEW 1
INSTALLATION 1
CONSOLE 1
INSTALLATION – STANDARD MODE 3
DynaJet® drivers .............................................................................................................................................................................................3
Power ..................................................................................................................................................................................................................3
Nozzle harnesses ............................................................................................................................................................................................3
Pressure sensor interface kit.......................................................................................................................................................................4
Boom interface module (BIM)....................................................................................................................................................................4
DynaJet® interface..........................................................................................................................................................................................4
CAN cables and terminators.......................................................................................................................................................................4
INSTALLATION – HIGH FLOW MODE 5
DynaJet® interface and drivers ..................................................................................................................................................................5
Connect terminators .....................................................................................................................................................................................5
Nozzle harnesses ............................................................................................................................................................................................5
Connect can cables to drivers....................................................................................................................................................................5
Driver battery cables .....................................................................................................................................................................................5
Boom harnesses..............................................................................................................................................................................................5
Pressure sensor................................................................................................................................................................................................5
DynaJet® 7120 console.................................................................................................................................................................................5
Other battery cable........................................................................................................................................................................................5
INITIAL STARTUP 8
Favorites.............................................................................................................................................................................................................8
Setup...................................................................................................................................................................................................................8
Units.........................................................................................................................................................................................9
Number of sections..................................................................................................................................................................9
Maximum pressure sensor value.............................................................................................................................................9
Nozzle selection ..............................................................................................................................................................................................9
Select nozzle series.........................................................................................................................................................9
Select nozzle capacity .....................................................................................................................................................9
Ready to pressure test the system......................................................................................................................................................... 10
Work screen ................................................................................................................................................................................................... 10
On screen indicators..............................................................................................................................................................10
Droplet size chart...........................................................................................................................................................10
USER SETTINGS 11
OEM settings ................................................................................................................................................................................................. 13
Enable/disable options...........................................................................................................................................................13
TUNING DYNAJET® 13
DYNAJET® NOZZLE SELECTION 14
Nozzle selection example......................................................................................................................................................................... 15
55295 E-CHEMSAVER® MAINTENANCE INSTRUCTIONS 16
General disassembly and reassembly.................................................................................................................................................. 16
APPLICATION RATES AT GIVEN SPEED 17

1www.teejet.com
DynaJet®Flex
DYNAJET® FLEX OVERVIEW
The DynaJet Flex controller works in conjunction with an existing rate controller that regulates ow via a control valve or pump regulation to
achieve a target application rate while maintaining target droplet size(s) when a speed change occurs. This system only works with automatic
rate controllers that use ow based monitoring systems and not pressure based monitoring systems. Automatic rate controllers equipped for
both ow and pressure based control should have the pressure-based system disabled to work in conjunction with DynaJet Flex.
The independent automatic rate controller loop performs the same as it would if the DynaJet controller were not present. The DynaJet Flex
controller changes ow output to each individual nozzle based upon input provided from the operator about the optimum droplet size
(pressure) for the application.
INSTALLATION
CONSOLE
The DynaJet Flex console is designed to provide years of service under typical agricultural and turf operating conditions. A tight tting
enclosure means that typical dusty environments will not cause operational problems. While occasional splashing of water will not damage
the unit, the DynaJet Flex console is not designed for direct exposure to rain. Take care not to operate the DynaJet Flex console in wet
conditions.
Figure 1: DynaJet Flex 7120 console front and back
to DynaJet interface
harness connection
Power switch
USB port
Standard RAM bracket
Bright touch screen
Safety information
TeeJet Technologies is not responsible for damage or physical harm caused by failure to adhere to the following safety
requirements.
As the operator of the vehicle, you are responsible for its safe operation.
The DynaJet Flex is not designed to replace the vehicle’s operator.
Be sure that the area around the vehicle is clear of people and obstacles before and during engagement.
The DynaJet Flex is designed to support and improve efciency while working in the eld. The driver has full responsibility for the quality and
work related results.

2
98-05334-EN R2
DynaJet®Flex
Figure 3: System diagram - standard mode
90-02887 - DynaJet 7120 Console w/RAM Mount Kit
Kit includes: Console and Mount
45-10148 - Sentry Interface Harness
78-05091 - Boom Interface Module (BIM)
78-05106 - DynaJet Interface
45-05963 - CAN Bulkhead Cable
45-05965 - CAN to Bulkhead Cable
DynaJet Pressure Sensor Interface Kit
Kit includes: Interface, Sensor Cable, and Pressure Sensor
90-04007: 3 m
90-04008: 10 m
78-05122 - DynaJet Driver
45-05855 - CA
N Terminator, Female (Start)
35-50048 - DynaJet Solenoid
45-05943 - Battery 60 AMP Fuse Cable
78-05121-xx - Power Distribution Module
45-05971-xx - Driver to Power Extension Cable
45-05980-xx -
Driver to Power
“Y” Cable45-05942-xx - 6 Gauge Power Extension Cable
45-10142 - BIM Harness
401-0016 - Power Cable
45-05936-xx - Tip Harness Ext
ension
45-05948-xx - Solenoid Extension Cable
45-05935-20-xx -
Tip Harness
to 12V Power
Boom Sense Wires
Sensor Cable
Pressure Sensor
to Battery Power
45-05856 - CAN Terminator, Male (End)
Console Extension Cable
45-05900: 1.5 m
45-05901: 3 m
45-05902: 6 m
45-05903: 12 m
45-058xx - CAN Extension Cable
Interface LED - Flashes until
CAN message is received,
then on steady

3www.teejet.com
DynaJet®Flex
CAN Start Terminator
(female)
at Boom Section 1
DynaJet Solenoids
to CAN connection
DynaJet Solenoids
Power Distribution Module
Nozzle Harness
DynaJet Driver
DynaJet Solenoids DynaJet Solenoids
Nozzle Harness
DynaJet Driver
DynaJet Solenoids DynaJet Solenoids
Nozzle Harness
DynaJet Driver
DynaJet Solenoids DynaJet Solenoids
Nozzle Harness
DynaJet Driver
INSTALLATION – STANDARD MODE
DynaJet® drivers
There will be one DynaJet driver 78-05122 per boom section with a
limit of 20 nozzles per section.
• Mount them so they are at the end of each section that is
closest to the middle of the boom.
Power
Power will be sourced from the battery using the 60 amp fused cable
45-05943.
Power from the battery will be routed to the boom using the 6 gauge
power cables 45-05942-xx
The power distribution modules 78-05121-xx will connect to the
45-05942-xx cables.
Power will then route from 78-05121-xx to each DynaJet driver
78-05122 using cables 45-05971-xx.
Figure 2: Installation diagram - standard mode
Nozzle harnesses
When installing nozzle harnesses 45-05935-xx-xx always start with
section 1 and continue to the last section.
Each section will require nozzle harnesses designed for your specic
nozzle spacing and number of nozzles.
• Nozzle harnesses are built with an even number of outputs.
• Some sections will use more than one harness to equal the
number of nozzles in that section.
The yellow and white solenoid cables on the nozzle harnesses must
alternate across the entire boom. When sections have odd numbers
of nozzles then accounting for the altering can be accomplished
one of two ways:
A. By crossing the two solenoid cables
B. By installing nozzle harness reversing adapters 45-05952

4
98-05334-EN R2
DynaJet®Flex
CAN Start Terminator
(female)
at Boom Section 1
DynaJet Solenoids
to CAN connection
DynaJet Solenoids
Power Distribution Module
Nozzle Harness
DynaJet Driver
DynaJet Solenoids DynaJet Solenoids
Nozzle Harness
DynaJet Driver
DynaJet Solenoids DynaJet Solenoids
Nozzle Harness
DynaJet Driver
DynaJet Solenoids DynaJet Solenoids
Nozzle Harness
DynaJet Driver
Pressure sensor interface kit
The DynaJet system requires pressure sensor interface kit 90-04007
or 98-04008 to be installed.
• The pressure sensor interface kit should be mounted close to
the boom manifold.
Boom interface module (BIM)
The boom interface module (BIM) 78-05091 is used by the DynaJet
system for boom sense.
The BIM harness connects between the BIM and the can.
On the BIM harness 45-10142, the boom sense wires (or ying
leads) are supplied to tie into existing machine boom section
12V on/0V off outputs.
If not using 45-10142, some machine specic harnesses are
available.
The BIM can be mounted in the cab or outside depending upon your
installation.
DynaJet® interface
The DynaJet interface 78-05106 connects to the Sentry interface
harness 45-10148:
The Sentry interface harness connects to
A. The console 75-30119 (extension cable may be used)
B. Power 12V for powering the CAN
C. CAN
The DynaJet interface can be mounted in the cab or outside
depending upon your installation.
CAN cables and terminators
The start terminator 45-05855 must be connected to the DynaJet
driver 78-05122 for section 1.
Can cables must be connected in series:
A. To each DynaJet driver 78-05122
B. To the boom interface module 78-05091 (via BIM harness
45-10142)
C. To the DynaJet interface 78-05106 (via sentry interface
harness 45-10148)
D. To the pressure sensor interface kit (via pressure interface
78-05110)
The end terminator 45-05856 must be connected to the driver
module 78-05122 for the last section.

5www.teejet.com
DynaJet®Flex
INSTALLATION – HIGH FLOW MODE
The following illustration and steps are only a guideline of an installation based on a specic vehicle conguration. Installations on
other vehicles may vary. If there are questions concerning the installation of the DynaJet Flex system on this vehicle, or due to the
changes in component specications the parts supplied in the kit are not exactly as presented in this document, please contact
your dealer or TeeJet customer service representative for clarication before installation. TeeJet technologies is not responsible for misuse or
incorrect installation of the system.
DynaJet® interface and drivers
Step 1a – mount the (F) DynaJet HF drivers 78-05124 onto brackets, one for each boom section.
Step 1b – mount the (D) DynaJet HF interface 78-05123, connecting to the (C) DynaJet interface harness 45-10177, and (H) boom harness
45-10178.
Connect terminators
Step 2a – connect the (I) start terminator 45-05855 to (K) 4 nozzle harness (1-4) 45-10174, rst section.
Step 2b – connect the (J) end terminator 45-05856 to (M) 4 nozzle harness (9-12) 45-10176, last section.
Nozzle harnesses
Step 3 – install nozzle harness (K) 4 nozzle harness (1-4) 45-10174, (L) 4 nozzle harness (5-8) 45-10175, and (M) 4 nozzle harness (9-12)
45-10176. Each harness features two solenoid connections per nozzle body, supporting (4) nozzle bodies in total.
Note: specific section breakdown may vary by installation
Connect can cables to drivers
Step 4 – using the (E) can extension cables, connect the (I) DynaJet HF drivers 45-05124 to the (D) DynaJet HF interface 78-05123.
Driver battery cables
Step 5 – connect the battery cable 45-05987 to the three (3) (F) DynaJet HF drivers 78-05124, and to the battery.
Boom harnesses
Step 6 – install the (H) boom harnesses 45-10178, 45-10179, or 45-10181 connecting to the (D) DynaJet HF interface 78-05123.
Pressure sensor
Step 7 – connect the boom pressure sensor 0-10 bar to the (C) DynaJet HF interface harness 45-10177. The pressure sensor interface kit
should be mounted close to the boom manifold
DynaJet® 7120 console
Step 8 – connect the (A) DynaJet 7120 console 90-02887 to the (C) DynaJet HF interface harness 45-10177 via console extension cables.
Other battery cable
Step 9 – connect 401-0012 to the battery and route leads as needed.

6
98-05334-EN R2
DynaJet®Flex
Figure 4: System diagram - high flow mode
(H) Boom Harness
45-10178 to IC18
45-10179 to Raven 440
45-10181 to Raven Envizio
(F)
78-05124
DynaJet HF Driver
(D) 78-05123
DynaJet HF Interface
(C) 45-10177
DynaJet Interface Harness
(M) 45-10176
4 Nozzle Harness 9-12
(L) 45-10175
4 Nozzle Harness 5-8
(K) 45-10174
4 Nozzle Harness 1-4
(A) 90-02887 - DynaJet 7120 Console w/RAM Mount Kit
Kit includes: Console and Mount
Sensor Cable
Pressure Sensor
(I)
45-05855
CAN Terminator,
Female (Start)
to Battery Power
to Battery Power
to Battery Power to Battery
(J) 45-05856
CAN Term
inator,
Male (End)
(B) Console Extension Cables
45-05900: 1.5 m
45-05901: 3 m
45-05902: 6 m
45-05903: 12 m
(E) 45-058xx
CAN Extension Cable
(G) DynaJet Pressure Sensor Interface Kit
Kit includes: Sensor Cable and Pressure Sensor
90-04007: 3 m
90-04008: 10 m

7www.teejet.com
DynaJet®Flex
Item Part # Description Illustration
A90-02887 DynaJet 7120 console
B45-05900: 1.5 m
45-05901: 3 m
45-05902: 6 m
45-05903: 12 m
Console extension cable
C45-10177 DynaJet interface harness
D78-05123 DynaJet HF interface
E45-05857: 1 m
45-05858: 2 m
45-05859: 4 m
45-05864: 10.5 m
CAN extension cable
F78-05124 DynaJet HF driver
G90-04007: 3 m
90-04008: 10 m
DynaJet pressure sensor interface kit
H45-10178 to IC18
45-10179 to Raven 440
45-10181 to Raven Envizio
Boom harness
I45-05855 CAN terminator, female (start)
J45-05856 CAN terminator, male (end)
K45-10174 4 Nozzle harness 1-4
L45-10175 4 Nozzle harness 5-8
M45-10176 4 Nozzle harness 9-12
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali TeeJet Technologies Sistema di controllo