TESTO 440 Manuale utente

testo 440 – Climate Measuring Instrument
Instruction manual


Contents
Contents
1Safety and disposal.............................................................................. 3
1.1 About this document..............................................................................3
1.2 Security ..................................................................................................3
1.3 Warning notices .....................................................................................4
1.4 Disposal .................................................................................................5
2Description of the instrument ............................................................... 6
2.1 Use.........................................................................................................6
2.2 Overview of testo 440 ............................................................................6
2.3 Display overview ....................................................................................7
2.4 Magnetic holder .....................................................................................8
2.5 Power supply .........................................................................................9
2.6 Probe overview ....................................................................................10
2.6.1 Compatible cable probe ........................................................10
2.6.2 Compatible Bluetooth®probe ...............................................11
2.6.3 Compatible NTC probe .........................................................11
2.6.4 Compatible Smart Probes .....................................................12
3Operation........................................................................................... 12
3.1 Commissioning ....................................................................................12
3.2 Switching the testo 440 on/off .............................................................13
3.3 Making basic settings ..........................................................................14
3.3.1 Establishing a Bluetooth®connection ...................................14
3.3.2 Setting power options ...........................................................15
3.3.3 Setting the ambient conditions..............................................16
3.3.4 Configuring the unit system...................................................17
3.3.5 Setting the date and time ......................................................17
3.3.6 Setting the language..............................................................18
3.3.7 Showing general device information .....................................18
3.3.8 Humidity adjustment..............................................................19
3.3.9 Resetting the instrument or probe to default settings ...........20
3.4 Managing saved measurement data....................................................20
3.4.1 Printing ..................................................................................23
3.4.2 CSV export ............................................................................24
3.5 Carrying out measurements.................................................................26

Contents
3.5.1 Connecting the cable probe with testo 440.......................... 26
3.5.2 Connecting the Bluetooth®probe with testo 440 ................. 26
3.5.3 Basic View ............................................................................ 27
3.5.4 Selecting application menus................................................. 28
3.5.5 Volume flow application [Volume Flow] ................................ 29
3.5.6 Funnel volume flow application [Funnel Volume Flow] ......... 31
3.5.7 Pitot volume flow application [Pitot Volume Flow] ................ 33
3.5.8 K-factor volume flow application [K-Factor Volume Flow].... 35
3.5.9 Heating/cooling load application [Heating/Cooling Load]..... 36
3.5.10 Mold indication application [Mold Indication] ....................... 38
3.5.11 Turbulence measurement application [Draft Rate]................ 40
3.5.12 Performing long-term measurement application [Logger
Mode].................................................................................... 41
4Maintenance ...................................................................................... 43
4.1 Battery replacement ............................................................................ 43
4.2 Cleaning testo 440............................................................................... 43
4.3 Calibration ........................................................................................... 43
4.4 Carrying out a firmware update ........................................................... 44
5Technical data ................................................................................... 45
6Tips and assistance ........................................................................... 47
6.1 Questions and answers ....................................................................... 47
6.1.1 LED status Bluetooth®probe................................................ 47
6.1.2 Hot wire measurement not possible ..................................... 47
6.2 Accessories and spare parts ............................................................... 47
7Authorisations and certification.......................................................... 49

1 Safety and disposal
3
1Safety and disposal
1.1 About this document
The instruction manual is an integral part of the instrument.
Pay particular attention to the safety instructions and warning advice in
order to prevent injury and damage to the product.
Keep this documentation on hand so that you can refer to it when
necessary.
Hand this instruction manual on to any subsequent users of the product.
1.2 Security
General safety instructions
Only operate the product properly, for its intended purpose, and within the
parameters specified in the technical data.
Do not apply any force.
Do not operate the instrument if there are signs of damage on the housing,
power supply or connected cables.
Dangers may also arise from objects to be measured or the measuring
environment. Always comply with the locally valid safety regulations when
carrying out measurements.
Do not store the product together with solvents.
Do not use any desiccants.
Only perform maintenance and repair work on this instrument that is
described in this documentation. Follow the prescribed steps exactly when
doing the work.
Use only original spare parts from Testo.
Maintenance work that is not described in this documentation must only be
carried out by trained service engineers.
Temperature information given on probes/sensors relates only to the
measuring range of the sensor technology. Do not expose handles and feed
lines to temperatures in excess of 70 °C (158 °F), unless they are expressly
authorized for use at higher temperatures.

1Safety and disposal
4
Do not carry out any contact measurements on uninsulated, live parts.
Transport and store the instrument only in the associated packaging, in
order to prevent any damage to the sensor.
Batteries
Improper use of batteries may cause the batteries to be destroyed, or lead
to injury due to current surges, fire or escaping chemicals.
Only use the batteries supplied in accordance with the instructions in the
instruction manual.
Do not short-circuit the batteries.
Do not take the batteries apart and do not modify them.
Do not expose the batteries to heavy impacts, water, fire or temperatures in
excess of 60 °C.
Do not store the batteries in the proximity of metal objects.
Do not use any leaky or damaged batteries.
Take the rechargeable battery out of the instrument immediately if it is not
functioning properly or if it shows signs of superheating. Rechargeable
battery may be hot!
In the event of contact with battery acid: rinse affected areas thoroughly
with water, and if necessary consult a doctor.
When not in use for a long period of time, take the rechargeable battery out
of the instrument to prevent exhaustive discharge.
1.3 Warning notices
Always pay attention to any information marked with the following warning
notices along with warning pictograms. Implement the specified precautionary
measures!
DANGER
Risk of death!
WARNING
Indicates possible serious injury.
CAUTION
Indicates possible minor injury.

1 Safety and disposal
5
CAUTION
Indicates possible damage to equipment.
1.4 Disposal
Dispose of faulty rechargeable batteries and spent batteries in accordance
with the valid legal specifications.
At the end of its useful life, deliver the product to the separate collection
point for electric and electronic devices (observe local regulations) or return
the product to Testo for disposal.

2Description of the instrument
6
2Description of the instrument
2.1 Use
The testo 440 is used for measuring climate-related parameters. The testo 440
is particularly suitable for comfort level measurements for remove the
workplace evaluation and disturbance measurements in and at air conditioning
systems.
The instrument is only to be used by qualified personnel and must not be used
in potentially explosive atmospheres!
2.2 Overview of testo 440
Element Element
1 Settings 2 Confirm input/selection
3 Menu 4 Testo Universal Connector (TUC)
for connection of cabled probes
with corresponding plug

2 Description of the instrument
7
5 Type K thermocouple connection 6 Back
7 Navigation 8 Instrument ON/OFF
9 Micro USB port for data
transfers or connection to
external power supply
10 Connections for differential
pressure measurements
(+ / - labelling on rear of
instrument, only testo 440 dP)
2.3 Display overview
Element Element
1 Zero pressure sensor 2 Probe identification
3 Measuring values 4 Measuring Application
5 Status bar
Symbol Meaning
Start measurement
Stop measurement
Carry out multi-point measurement

2Description of the instrument
8
Symbol Meaning
Pause measurement
Save measurement
New measurement
Zero pressure sensor
2.4 Magnetic holder
Two magnets are integrated in the testo 440 measuring instrument. These can
be used as a holder on magnetic surfaces.
Element Element
1 Integrated magnet 2 Battery compartment
Altri manuali per 440
1
Indice
Altri manuali TESTO Strumento di misura

TESTO
TESTO 470 Manuale utente

TESTO
TESTO 454 Manuale utente

TESTO
TESTO 350 M/XL Manuale utente

TESTO
TESTO 606-1 Manuale utente

TESTO
TESTO Saveris 2 Manuale utente

TESTO
TESTO 608 - H1 Manuale utente

TESTO
TESTO 608 - H1 Manuale utente

TESTO
TESTO 410-1 Manuale utente

TESTO
TESTO 515 Manuale utente

TESTO
TESTO 480 Come usare

TESTO
TESTO 511 Manuale utente

TESTO
TESTO 570 Manuale utente

TESTO
TESTO 810 Manuale utente

TESTO
TESTO DiSCmini Manuale utente

TESTO
TESTO Saveris Series Manuale di formazione

TESTO
TESTO 915i Manuale utente

TESTO
TESTO 545 Manuale utente

TESTO
TESTO 340 Manuale utente

TESTO
TESTO 417 Manuale utente

TESTO
TESTO 400 Manuale utente