2.3 Technical Specifications
UT-30X
UT-100X
MULTI CHANNEL UNIVERSAL PROCESS INDICATOR
CONTROLLER/SCANNER/DATALOGGER
Flame Proof
K: -50~1200˚C
R: 0~1750˚C
T: 0~400˚C
General
Specificaion
Power Supply 110/240V AC, 50Hz, 4 Watts MaximumConsumption :
Mount. dimension
Operating Ambient Temp. : 0~50˚C, Humidity : Below 90% Non condensing
RTD PT-100 : -50~400˚C
4~20 :-1999~9999 Display
CURRENT [mA]
SPECIAL ON DEMAND
Linear: -1999~9999 Display
THERMO-COUPLE
Display resolution -1999 to 9999 fully configurable for each linear input
Enclosure [If Reqd.] FC-1 FC-2 :[1-Compartment] OR [2-Comp.] IIA, IIB Exter. keys & Cable Entries
FEATURES
J: -50~750˚C,
S: 0~1750˚C,
Programming Through 4 tactile keys
Relay Output NO-C-NC Contacts , 5A@240 VAC Resistive, 4 Relays for each input
Output
High scale / Low scale Full range as per input selection
Prog. parameters
Modbus RTU RS- 485/RS- 232 Communication
Baud rate, Parity, Node address, Stop bit
Protocols & method
Communication
Programmable
Parameters
Setpoint / Hysteresis Full range as per input selection
72x144 /144x144 /261x144 /288x144 & panel mounted
Other Output Transmitter Power Supply : Isolated 24VDC@100mA ,Max.
Wireless comunication
GSM / GPRS base mobile(SMS) communications.
·μP Based Power, full & highly reliable process display.
4/6/8/12/16/20/24 channel option available.·
All input are universal like T/C, RTD, linear selection.·
Simultaneously display for individual channel in compact size.·
0.1% Accuracy of FSD.·+
All channels are fully Isolation·
All Configurations and calibration from front panel keypad.·
Highly communicative Data interface facility (RS 485).·
Transmitter loop power supply with current limit as standard.·
Power supply :230V/110V AC. Or 24V/12V DC·
Optional GSM mobile connectivity.·
Fully Password Protected Operation.·
INPUT RANGE
0~20 :-1999~9999 Display
VOLTAGE [VDC] 0~10 :-1999~9999 Display
INPUT TYPE RANGE
Input
T/C K, J, R, S, T, E
RTD Pt-100, Pt-1000, Cu-53 [2 wire, 3 wire]
Linear : 4 ~20mA DC, 0~20mA DC, 0 ~5 Amp AC
CURRENT [Analog]
VOLTAGE [Analog]
Linear : 0.5~2.5VDC, 1~5VDC, 0~10VDC
SPECIAL ON DEMAND
Linear : 0~75m/0~200mVDC, 0~100/200/300VDC
Indication Display Indication 0.56” 4 Digit, 4 set 7 Segment Red Displays.
Status Indication Front Red LED for all Alarm High & Low status & for Communication
Accuracy
T/C + 0.25% of Full Scale
RTD Class A
+ 0.1% of Full Scale
ANALOG [V & I]
SPECIAL ON DEMAND
+ 0.1% of Full Scale
Automatic Software based self compensation
Cold Junction Comp.
“ ” or “ ” indication on displayOPEN OVER
Sensor Break Info.
AS per Input Range Table
Range Limits
>330 K for Voltage ,mV, and T/C, 100 R for current
Input Impedance
Alarm modes Full Scale Low / High Alarm
Control Mode
Dead Band controls High and Low Set point for level application
Relay Max. : 4 Nos.[one for each channel]
TECHNICAL SPECIFICATIONS
Type of Input
[All Input]