VAKI Bioscanner Manuale utente

Bioscanner
User Manual

Bioscanner Manual
www.vaki.is
Page 2of 25
TABLE OF CONTENTS
Table of contents 2
Warranty terms 4
List of items 5
1. Preface 6
2. Assembly instructions 7
2.1 V-channel 1 7
2.1.1 Attaching the PVC flap 8
2.1.2 Attaching the flange and the 90° elbow joints 8
2.1.3 Fitting the aluminium grating 9
2.1.4 Fitting the clamp 9
2.1.5 Installing the scanner unit 10
2.2 V-channel 3 10
2.2.1 Attaching the PVC plastic cover 11
2.2.2 Fitting the clamp 11
2.2.3 Installing the scanner unit 11
3. Operation 12
3.1 The principle functions of the Bioscanner channels 12
3.2 Controlling the water-flow 13
3.3 Slope of the channel 13
3.4 Level of the channel 14
3.5 Counting 14
3.6 Power failure! 14
3.7 End of operation 14
4. Control unit application 15
4.1. Overview 15
4.2. Main view 16
4.3. Size view 17
4.4. Throughput 18
4.5. Report View 19
4.6. Info View 21

Bioscanner Manual
www.vaki.is
Page 3of 25
5. Troubleshooting 22
5.1. Over counting 22
5.2. Undercounting 22
6. Technical Specifications 23
7. Avoiding problems with connectors 24
Appendix 25
Throughput chart 25
VAKI
Akralind 4, 201 Kópavogur
Iceland
Tel. 354 - 595 3000
Fax. 354 - 595 3001
www.vaki.is

Bioscanner Manual
www.vaki.is
Page 4of 25
WARRANTY TERMS
VAKI Aquaculture Systems Ltd. offers warranty for defects that appear within two (2) years from
the date of delivery by VAKI Iceland, on condition that the equipment has been assembled, used,
and maintained in accordance with the instructions for assembly and use.
VAKI undertakes to repair all defects that are due to faults in the design, materials used, or
manufacture of the equipment. These defects will be rectified by repairing the equipment, or
replacing components. The complete unit or parts thereof may be required to return to the
factory in Iceland for repair.
VAKI accepts corresponding warranty for original parts fitted by VAKI as replacements, for a
period of one (1) year from the date supplied.
VAKI will not be liable for:
Incorrect assembly and use, or inadequate maintenance.
Defects which result from the fitting of materials, components, or
devices not supplied by VAKI, and which are purchased and fitted by
the user.
Defects due to changes made to the equipment by the user, without
the written consent of VAKI.
Faulty or inadequate repairs carried out by the user.
Normal wear and tear of the equipment.
Faulty connection of electrical equipment.
Faults caused by excessive voltage.
Damage or stoppage due to immersion of the computer or camera in
water.
Damage to electrical supply cables.
Any economic loss that may arise from production stoppage.
If faults or defects appear in the equipment, the user must report this in writing to VAKI or its
appointed representative as soon as possible, and without unjustifiable delay. The report must
be sent within two (2) weeks from the expiry of the deadline, which is two (2) year from the date
of supply by VAKI Iceland.
If the purchaser does not inform VAKI or its representative within the time limits stated above,
the purchaser shall forfeit the rights of the warranty.

Bioscanner Manual
www.vaki.is
Page 5of 25
LIST OF ITEMS
The main parts of the Bioscanner are:
1) The scanner
mmm
2) Cable
3) Control unit –single
channel or multi –
channel.
4) V-channel

Bioscanner Manual
www.vaki.is
Page 6of 25
1. PREFACE
VAKI Aquaculture Systems Ltd thanks you for choosing the Bioscanner. More and more
aquaculture enterprises are using equipment from VAKI in their day-to-day production and
management. An accurate knowledge of the number of fish, and the average weight and size
distribution in each pen is the basis for success in today’s tough competition.
The Bioscanner is a sophisticated electronic device specially designed for counting both small and
large fish on fish farms. Among the clear benefits of using the Bioscanner are:
Manpower saving
Increased efficiency
Accurate data on number of fish in each size category
Efficient feeding and accurate medical dosage
A safer basis for insurance assessment
The Bioscanner is very gentle and the fish is not touched by any mechanic parts when counted,
and the fish are in water at all time. Correct set up and use of the Bioscanner fish counter is
essential for accurate results. Please read this manual carefully.
This manual is a guide to assembling the V-Channels and the use of the Bioscanner control unit.

Bioscanner Manual
www.vaki.is
Page 7of 25
2. ASSEMBLY INSTRUCTIONS
The Bioscanner V-channel is manufactured and packed ready for assembly by the user. V-CHANNEL
1is recommended for fish from 3 gr. - 750 gr. and V-CHANNEL 3is recommended for fish from 500
gr. - 6.000 gr. Following are the parts for V-CHANNEL 1.
2.1 V-CHANNEL 1
1. Glass-fibre reinforced polyester channel
2. Polyurethane flange
3. Rubber 0-ring
4. Two 90° PVC elbow joints
5. Aluminium grating
6. Transparent PVC flap
7. Stainless steel screws, bolts and nuts
8. Clamp

Bioscanner Manual
www.vaki.is
Page 8of 25
2.1.1 Attaching the PVC flap
Parts: 2 x M5 bolts, 2 x
M5 nuts, 4 x Ø5 washers.
Place the flap in position
at the end of the
channel. Fasten the flap
in position with the M5
bolts. Check that the flap
is hanging straight.
Adjust if necessary.
2.1.2 Attaching the flange and the 90° elbow joints
Prepare all the parts
needed: The channel, the
flange, the 0-ring, 4 M5 bolts
and nuts and the two elbow
joints. Place the 0-ring in the
recess in the flange and
fasten the flange to the
channel with the four bolts
and nuts shown, tighten the
nuts evenly. Before fitting
the 90° elbow joints to the
flange, lubricate them with
soap and/or water.

Bioscanner Manual
www.vaki.is
Page 9of 25
2.1.3 Fitting the aluminium grating
Tools required: Silicone
gun. Prepare the grating
and four M3 screws,
spacers and nuts. Make
sure that the smooth
side of the grating faces
upwards so as to avoid
injuring the fish. The
smooth side can be
identified by running
your fingers across the
grating.
2.1.4 Fitting the clamp
Prepare all the parts
needed: 4 M8 bolts, 4
washers and 4 M8 nuts.
Place the clamp in the inlet
of the channel, aligning the
holes on the clamp. Place all
8 mm screws in position
before tightening fully. To
prevent all bolts from
corroding, some grease has
been put on the bolts and
bushings.

Bioscanner Manual
www.vaki.is
Page 10 of 25
2.1.5 Installing the scanner unit
Place a washer on each
of the two wing screws.
Put the screws through
the pre-drilled holes in
the channel and secure
them with the plastic
locking washers. Place
the scanner unit in
position and secure it by
tightening the wing
screws.
2.2 V-CHANNEL 3
1. Glass-reinforced
polyester channel
2. Plastic cover with two
plastic strips
3. Clamp (with bolts and
screws)
4. PVC flap
5. Stainless steel screws,
bolts and nuts