About this Guide
This guide is suitable for novice, intermediate, and experienced
users, and is intended to help you successfully use the features and
capabilities of the CX10/CX10+ test set. It is assumed that you have
basic computer experience and skills, and are familiar with IP and
telecommunication concepts, terminology, and safety.
If you need assistance or have questions related to use of this product,
call or email our Customer Care department. Please have your serial
number and software version ready before contacting.
VeEX Customer Care
Tel: +1 408-970-9090
Email: [email protected]
Web: www.veexinc.com
Copyright © 2010 VeEX Incorporated. All rights reserved. VeEX, VePAL are
registered trademarks of VeEX Inc and/or its afliates in the USA and certain
other countries. Trademarks of VeEX Incorporated have been identied where
applicable; however, the absence of such identication does not affect the legal
status of any trademark.
No part of this user manual may be reproduced, translated into a foreign language,
or be transmitted electronically without prior agreement and written consent of VeEX
Inc as governed by International copyright laws.
Every effort was made to ensure that the information contained in this user manual
is accurate. Information is subject to change without notice and we accept no
responsibility for any errors or omissions. In case of discrepancy, the web version
takes precedence over any printed literature.
This device uses software either developed by VeEX Inc or licensed by VeEX Inc
from third parties. The software is condential and proprietary of VeEX Inc. The
software is protected by copyright and contains trade secrets of VeEX Inc or VeEX’s
licensors. The purchaser of this device agrees that it has receive a license solely
to use the software as embedded in the device, and the purchaser is prohibited
from copying, reverse engineering, decompiling, or disassembling the software.
Please direct all questions to your local VeEX Sales Ofce, Representative, or
Distributor. Or, contact VeEX technical support at www.veexinc.com.

CX10/CX10+ D07-00-036 Rev.B01 3
Table of Contents
1. Product Introduction ......................................................4
1.1 Principles of Operation ............................................5
2. Safety Information .........................................................5
3. Basic Operation .............................................................6
3.1 Keypad ....................................................................6
3.2 LCD Display ............................................................7
3.3 Settings ...................................................................7
3.4 Battery .....................................................................9
3.5 Connectors ..............................................................9
4. Operation .....................................................................10
4.1 Selecting a Library Cable or Setting Vp ................10
4.2 Cable Connection ..................................................11
4.3 Measuring Cable Length or Fault Distance ...........12
4.4 Tone Generator .....................................................14
4.5 Typical Cable Values .............................................14
4.6 ID Room Detection (CX10+ only) ..........................15
5. Warranty and Software ................................................15
5.1 Maintenance ..........................................................17
6. Product Specications .................................................18
7. Certications and Declarations ....................................19
8. About VeEX .................................................................20

CX10/CX10+ D07-00-036 Rev.B01
4
1. Product Introduction
The CX10/CX10+ is a handheld Cable Length Meter that
employs Fast-Edge Step Time Domain Reectometer (TDR)
technology to measure the length of power and telecom
cables. The unit is able to measure cable length, including
the distance to open or short circuit faults up to a range of
2000 meters (6000 feet).
Fast-Edge Step TDR technology measures cable length and
locate opens and shorts, with improved range and resolution.
Results are displayed directly on an alphanumeric LCD.
The units also incorporate an oscillating tone generator to
trace and identify pairs within a cable bundle using industry
standard tone probes.
An internal library of standard cable types enables accurate
distance measurement without having to enter the Velocity of
Propagation (Vp) values beforehand, while automatic cable
impedance compensation is another time saving feature.
In the event the CX10/CX10+ is connected to a live cable,
testing is suspended and audible and visual alarms alert
the user.
If the units are is accidentally connected to a cable carrying a
voltage greater than 10 Volts, a warning tone will be emitted
and a “Voltage Detected” message will be displayed. This is
a great Safety Feature protecting the technician in potentially
hazardous working conditions.
A shutdown feature automatically turns the unit off after four
minutes of inactivity, preserving battery life.

CX10/CX10+ D07-00-036 Rev.B01 5
1.1 Principles of Operation
The TDR works on the same principle as radar, where a
pulse of energy is transmitted down a cable. When the pulse
reaches a fault or the end of the cable, a portion or all of the
pulse energy is reected back to the instrument.
The TDR measures the time it takes for the signal to travel
down the cable, detect the problem, and to reect back. The
TDR then converts this time to distance and displays the
information as a waveform and/or distance reading.
The CX10/CX10+ works by measuring the time taken for a
signal to travel to the far end of the cable under test, or to
an intermediate fault, and return.
The velocity at which the signal travels (Vp - Velocity of
Propagation) will depend on the characteristics of the cable.
2. Safety Information
Safety precautions should be observed during all phases
of operation of this instrument. The instrument has been
designed to ensure safe operation, however, please observe
all safety markings and instructions.

CX10/CX10+ D07-00-036 Rev.B016
Voltage Safety Warning: If the CX10/CX10+
is accidentally connected to a cable carrying a voltage greater than
approximately 10V, a warning tone will be emitted and the instrument
display will show “Voltage Detected”. Testing will be inhibited and
the operator should immediately disconnect the unit from the cable.
The CX10/CX10+ has been manufactured in accordance
with and meets the requirements of the following standards:
• SAFETY IEC 61010-1 and EN 60950
• EMC BS/EN 61326-1
• EMC EN50081 and EN50082 Light Industrial
• Water/Dustproof to IP54
3. Basic Operation
3.1 Keypad
The unit is powered on and off from the red key on the
keyboard area. In order to turn off the unit, press the power
key for at least 2 seconds. If the unit is not responding,
holding the power key down by more than 10 seconds will
force the unit to power down.
The keypad comprises the
following keys:
LCD display
Navigation down/up
Toggle key
TDR
Power On/Off

CX10/CX10+ D07-00-036 Rev.B01 7
3.2 LCD Display
The CX10/CX10+ is equipped with a 2x16 digit alpha-
numeric LCD display. Upon power up, the screen will display:
• Model #
• Software version programmed into the unit
• Last cable type tested
• Last Vp setting
• Battery status indicator - An all black battery
indicates fully charged condition, however as the
battery discharges, the indicator changes to white
3.3 Settings
The following can be set according to user preference:
Measurement units, Language, Library, and Contrast.

CX10/CX10+ D07-00-036 Rev.B018
To change the settings:
• Hold down the TDR key and press the key
• Pressing the key will now toggle between the
settings
• Press the and arrow keys to change the
options for each setting
See below for information on editing the Cable Library.
3.3.1 Cable Library
The CX10/CX10+ comes pre-installed with Velocity of
Propagation (Vp) characteristics.
Appletalk Belden 8102 Belden 9933
BT2002 CAT5 STP CAT 5 UTP
Coax Air 50 Coax Air 75 Coax A/S 50
Coax A/S 75 Coax Foam PE Coax Foam PE75
Coax Solid PE 50 Coax Solid PE 75 CW1308
Ethernet 9880 Ethernet 9901 Ethernet 9903
Ethernet 9907 IBM 1/2/A/6 IBM Type 3
IBM Type 9 Mains BS6500 Multicore PVC
RG6/U RG58 (8219) RG58 C/U
RG59 B/U RG62 A/U T/Pair Jelly PE
T/Pair PE T/Pair PTFE T/Pair PVC
T/Pair Paper 72nF T/Pair Paper 83nF Twinax 78
Twinax 100 URM70 Coax URM76 Coax
To add a custom cable, follow the steps above to access the
Edit Library settings. Use the up and down arrows keys to
scroll between the cable and key to modify the characters.

CX10/CX10+ D07-00-036 Rev.B01 9
3.4 Battery
The CX10/CX10+ operates from 6 Volts provided by 4x1.5
Volt Alkaline batteries (AA) located in the rear of the unit. The
battery life is 100 hours of continuous scanning. To preserve
battery life, the units are tted with an auto shutdown feature.
Four minutes after the last key press, the auto shutdown
feature turns the unit off automatically. To replace the
batteries, follow the procedure below:
1. Disconnect the instrument from cable under test
2. Turn the instrument off
3. Loosen the two black screws and remove the
battery compartment cover
4. Replace the batteries with four 1.5 Volt Alkaline
batteries (AA size), observing the polarity markings
5. Ret the battery compartment cover and the two
cover screws
3.5 Connectors
The unit can be equipped with Banana jacks or BNC
connector types.
2x 4mm Banana
BNC
• Ensure no power supply or
equipment is attached to the
cable under test
• Ensure the far end of the cable
under test is open or shorted
(not tted with a resistive
termination)
• Voltage protection up to 250
Volts AC

CX10/CX10+ D07-00-036 Rev.B0110
4. Operation
4.1 Selecting a Library Cable or Setting Vp
After switching on the CX10/CX10+ and viewing the version
and battery life information, the display will show the last
cable type tested and/or the last Vp setting.
Press the and arrow keys to move through the cable
library. If the cable to be tested is not listed, or a different
Vp is required, continue pressing the up arrow key, past the
top of the library, where Vp settings between 1% and 99%
can then be selected.
When the units are turned off, the last cable library or Vp
setting will be remembered. This feature is useful in the
situation where the cable operator is performing many tests
on the same type of cable, as is generally the case.
Note: Determining unknown Vp values
If the CX10/CX10+ is to be used with a cable type for which the Vp
is unknown, this value must rst be determined:
1. Take a sample of the cable at least 20m (60ft) long
2. Measure the actual length of cable using a rule or tape
measure or some other reliable method
3. Connect the CX10/+ and adjust the Vp setting until the test
give a correct reading of the sample length
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali VeEX Strumento di misura

VeEX
VeEX FX41xT Manuale utente

VeEX
VeEX FX20 Manuale utente

VeEX
VeEX VePAL MX120e+ Manuale utente

VeEX
VeEX CX380X Manuale utente

VeEX
VeEX FX150 Manuale utente

VeEX
VeEX VePal CX350 Manuale utente

VeEX
VeEX RTU-4000 Manuale utente

VeEX
VeEX FX80 PON Manuale utente

VeEX
VeEX TX50e Guida

VeEX
VeEX FX80 Manuale utente

VeEX
VeEX FX86 Manuale utente

VeEX
VeEX FX80 Manuale utente

VeEX
VeEX VEPAL CX350S-D3.1 Manuale utente

VeEX
VeEX MPA Manuale utente

VeEX
VeEX FX15 Manuale utente

VeEX
VeEX VePAL TX300 Manuale utente

VeEX
VeEX CX180F Manuale

VeEX
VeEX FX8 Series Manuale utente

VeEX
VeEX FX180X Manuale utente

VeEX
VeEX TX150 Manuale utente