Origin Setup and Maintenance Guide
© Copyright 2018 Vicon Motion Systems Limited. All rights reserved.
Vicon Motion Systems Limited reserves the right to make changes to information in this document without notice.
Companies, names, and data used in examples are fictitious unless otherwise noted. No part of this publication may be
reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic or mechanical, by
photocopying or recording, or otherwise without the prior written permission of Vicon Motion Systems Ltd.
Vicon® is a registered trademark of Oxford Metrics plc. Vicon Beacon™, Vicon Blade™, Vicon Control™, Vicon Evoke™,
Vicon Lock™, Vicon Lock+™, Vicon Lock Lab™, Vicon Lock Studio™, Vicon MX™, Vicon Nexus™, Vicon Origin™,
Vicon Pegasus™, Vicon ProCalc™, Vicon Pulsar™, Vicon Shōgun™, Vicon Studio™, T-Series™, Vicon Tracker™,
Vicon Vantage™, Vicon Vero™, Vicon Vertex™, Vicon Viper™, and Vicon Vue™ are trademarks of Oxford Metrics plc.
VESA® is a registered trademark owned by VESA (www.vesa.org/about-vesa/). Other product and company names
herein may be the trademarks of their respective owners. For full and up-to-date copyright and trademark
acknowledgements, visit https://www.vicon.com/vicon/copyright-information.
Vicon Motion Systems is an Oxford Metrics plc company.
Contents
About this guide............................................................................. 3
Introducing the Origin system ..................................................... 4
Origin system components........................................................5
Pulsar status LEDs and button ................................................. 7
Using the Pulsar button.............................................................8
Battery run time ..........................................................................9
Setting up an Origin system....................................................... 10
Start Evoke and load tracking objects ...................................11
Turn on Beacon, check status and set pairing mode.......... 12
Turn on clusters and pair with a Beacon............................... 13
Preparing Origin for a live experience .......................................15
Maintaining an Origin system .................................................... 16
Replace a failed cluster............................................................ 17
Unpair a cluster .........................................................................18
Monitor status ........................................................................... 19
Install in multiple volumes...................................................... 20
Manage object groups for gear up/gear down..................... 21
Hardware specifications for Origin systems............................ 23
DRAFT

Origin
Setup &
Maintenance
Guide
Vicon Motion Systems Ltd. 11-Oct-2018 Page 2 of 44
Viper camera specification..................................................... 24
Cluster specification ............................................................... 26
Beacon specification................................................................ 27
Charger specification .............................................................. 28
Origin system safety and regulatory information...................29
Radio and television interference regulatory information.30
Environmental regulations (UK & EU customers)............... 34
CE Declaration of Conformity (Vicon Pulsar).......................37
CE Declaration of Conformity (Vicon Viper)........................ 38
Specific Absorption Rate (SAR) certification...................... 39
Other important safety information...................................... 40
DRAFT

Origin
Setup &
Maintenance
Guide
Vicon Motion Systems Ltd. 11-Oct-2018 Page 3 of44
About this guide
This guide provides information on system setup and maintenance for
operators of the Origin system from Vicon.
DRAFT

Origin
Setup &
Maintenance
Guide
Vicon Motion Systems Ltd. 11-Oct-2018 Page 4 of44
Introducing the Origin system
The following topics provide an introduction to the Origin system:
•Origin system components (page 5)
•Pulsar status LEDs and button (page 7)
•Using the Pulsar button (page 8)
•Battery run time (page 9)
DRAFT

Origin
Setup &
Maintenance
Guide
Vicon Motion Systems Ltd. 11-Oct-2018 Page 5 of44
Origin system components
The Origin system comprises the following components:
Component Description
PC running
Vicon Evoke
software
Spec/requirements TBC
Evoke is the Vicon app that controls Vicon devices and
outputs object poses via the DataStream SDK.
Viper
cameras
Approved description to come - with RGB status LED, IR
positioning LED, temperature sensors and accelerometer.
PoE switch Spec/requirements TBC
Ethernet
cabling
Standard RJ-45 terminated Cat5e cable
Vicon
Beacon
wireless
synchroniza
tion unit
Vicon master synchronization unit whose main function
is to receive the Vicon Ethernet synchronization pulse
from the PoE+ and broadcast this wirelessly to Pulsar
clusters. It broadcasts the sync signal over Ethernet for
the cameras and over the radio at 2.4 GHz for the
clusters. This ensures the cluster LEDs are on only during
the camera exposure period, maximizing power
efficiency.
DRAFT

Origin
Setup &
Maintenance
Guide
Vicon Motion Systems Ltd. 11-Oct-2018 Page 6 of44
Component Description
Pulsar
clusters
Synchronized active tracking objects containing eight
LEDs that can be configured inunique LED patterns to
allow for tracking by the Evoke software. The clusters are
battery-operated and rechargeable through a standard
micro-USB connection.
Micro-USB
charger
cable
Standard micro-USB cable?
Note that an additional app (TBC) is required to control Evoke and
connected Vicon devices.
DRAFT

Origin
Setup &
Maintenance
Guide
Vicon Motion Systems Ltd. 11-Oct-2018 Page 7 of44
Pulsar status LEDs and button
LED status Description
Green on Pulsar battery is charging*
Green off Pulsar battery is fully charged
Red on Pulsar battery low (<=20%)
Red off Pulsar battery has charge (>20%)
Blue off Radio disabled
Blue on Pulsar paired to Beacon
Blue on → Blue off (slow
pulsing)
Pulsar on and paired but not receiving
comms from Beacon (will be in continuous
mode)
Blue on → Blue off (fast
pulsing)
Pulsar on but not paired (will be in
continuous mode)
Red on → Red off → Blue
on → Blue off → Green on
→ Green off
Boot sequence
Red on → Red off → Blue
on → Blue off → Green on
→ Green off (sequence
repeating)
Cluster selected in software
* To ensure the charge indication LEDs are visible, the cluster automatically
switches on when plugged into the charger.
Available user commands:
• Status LEDs can be disabled.
• Enable/disable selection of Pulsar.
DRAFT

Origin
Setup &
Maintenance
Guide
Vicon Motion Systems Ltd. 11-Oct-2018 Page 8 of44
Using the Pulsar button
To Do this
Turn on cluster On a cluster that is turned off, give the button a
single short press.
Turn off cluster On cluster that is turned on, press the button for 2
seconds.*
Reboot cluster
(retains settings)
On cluster that is turned on, press the button for 10
seconds.*
Unpair cluster
from Beacon
During the 10-second period after booting only,
double-press the button.
*Can be disabled in software to prevent accidental use.
DRAFT

Origin
Setup &
Maintenance
Guide
Vicon Motion Systems Ltd. 11-Oct-2018 Page 9 of44
Battery run time
The following measurements have been performed with multiple prototype
units that are representative of final production hardware. They are
presented here to assist Dreamscape in specifying the number of units to
provide for their setup. However, the final numbers stated in released
documentation may differ once extended testing has been complete. Leave
in for now?****
Condition LED power
setting
Run time Estimated
run time
after 500
charge
cycles
Running continuously 75% 14h 8h
50:50 duty cycle IR LEDs on/off
(radio and status LEDs still on)
75% 20h 12h
50:50 duty cycle IR LEDs on/off
(radio and status LEDs still on)
100% 18h 11h
DRAFT

Origin
Setup &
Maintenance
Guide
Vicon Motion Systems Ltd. 11-Oct-2018 Page 10 of44
Setting up an Origin system
To set up your Origin system, complete the following procedures:
•Start Evoke and load tracking objects (page 11)
•Turn on Beacon, check status and set pairing mode (page 12)
•Turn on clusters and pair with a Beacon (page 13)
Important
Before you begin, ensure Beacon is connected to a powered PoE
switch and that this switch is connected to the host PC, which runs
Evoke.
DRAFT
Indice
Altri manuali Vicon Sistema di controllo