Vision Engineering SWIFT PRO Series Manuale utente

9Swift PRO Duo
9Swift PRO Cam
9Swift PRO Elite
User Guide
Vision Engineering Ltd has been
certified for the quality management
system ISO 9001:2015.
FM 557119
Est. 1958
www.visioneng.com
Swift PRO series of optical and
video measuring systems


General
Intended use of equipment:
Swift PRO provides high accuracy non-contact
measurement of complex manufactured components
and materials.
Safety
Before using your system for the rst time, please read
the Health & safety section of the user guide.
Ensure that:
Your system and accessories are operated, maintained
and repaired by authorised and trained personnel only.
All operators have read, understood and observe the
user manual, in particular the safety regulations.
Cleaning
Disconnect your system from the electrical source
before cleaning.
Do not use any unsuitable cleaning agents, chemicals
or techniques for cleaning.
Never use chemicals to clean coloured surfaces or
accessories with rubberised parts.
Use a specialist lens cloth to clean optical surfaces.
Servicing
Repairs may only be carried out by Vision Engineering-
trained service personnel. Only original Vision Engineering
spare parts may be used.
Symbols used
Warning!
A potential risk of danger exists. Failure to comply can
cause i) a hazard to personnel; ii) instrument malfunction
and damage. Please consult the operating instructions
provided with the product.
Warning of electrical shock hazard
This symbol indicates the presence of electric shock
hazards. Please consult the operating instructions
provided with the product.
Important information
This symbol indicates important information. Please
carefully follow the instructions or guidelines.
Health & safety
Unauthorised alterations to the instrument
or non-compliant use shall invalidate all
rights to any warranty claims.
Electrical safety
Disconnect your system from the electrical source
before undertaking any maintenance.
Avoid using any form of liquid near the system.
Do not operate your system with wet hands.
Heat safety
A dust cover is supplied with your system. Turn off
your system and ensure it has cooled down before
using the dust cover.
Illumination safety
Do not look directly at the illuminated LED’s. This may
cause damage to the eyesight.
Environmental considerations
Avoid large temperature uctuations, direct sunlight
and vibrations.
Ensure electrical components are at least 10cm from
walls and combustible materials.
Position the system on a rm, rigid and level table.
The equipment should be positioned so that access to
the electrical input connector is always available.
Avoid positioning your system where bright reections
may affect the image.
Operator wellbeing
The advanced ergonomic design and construction
of Vision Engineering products are intended to
deliver superior ergonomic performance, reducing
the exertion of the user to a minimum. Depending
on the duration of uninterrupted work, appropriate
measures should be taken to sustain optimal operator
performance. This could include: Optimal arrangement
of workplace; Variation in task activity; Training of
personnel on workplace ergonomics and general
health and safety principles.
It is important to set-up and optimise your working
environment correctly in order to obtain maximum benet
from the advanced ergonomic design of your system. For
more information visit: www.visioneng.com/ergonomics
Compliance statements
Vision Engineering and its products conforms to the
requirements of the EC Directives on Waste Electrical and
Electronic Equipment (WEEE) and Restriction of Hazardous
Substances (RoHS).
All Vision Engineering products conform to the CE mark,
demonstrating that each product meets the requirements
of the applicable EC directives. Where applicable, other
characteristics of the CE directive are implied such as
essential health and safety requirements from all the
directives that applies to its product, including low
voltage directive and the EMC directive.

UNPACKING
1 2 3
Copyright
Copyright © 2017 Vision Engineering Ltd., The Freeman
Building, Galileo Drive, Send, Woking, Surrey GU23 7ER,
UK All Rights Reserved.
Mantis® (1532468), Lynx® (3672061) and Dynascope®
(915579) are registered trademarks of Vision Engineering
Ltd. The use of our trademarks is strictly controlled and
monitored and any unauthorised use is forbidden.
Copyright in this document is owned by Vision
Engineering Ltd. Any person is hereby authorised to
view, copy, print and distribute this document subject to
the following conditions:
The document may be used for informational purposes
only
The document may be used for non-commercial
purposes only
Any copy of this document or portion thereof must
include this copyright notice
Revision 1.0, published June 2017 by:
Vision Engineering Ltd.
The Freeman Building, Galileo Drive, Send,
Woking, Surrey, GU23 7ER, UK
www.visioneng.com
Disclaimer
This document is provided “as is” without any warranty
of any kind, either express or implied, statutory or
otherwise; without limiting the foregoing, the warranties
of satisfactory quality, tness for a particular purpose or
non-infringement are expressly excluded and under no
circumstances will Vision Engineering Ltd. be liable for
direct or indirect loss or damage of any kind, including
loss of prot, revenue, goodwill or anticipated savings.
All such warranties are hereby excluded to the fullest
extent permitted by law.
We have compiled the texts and illustrations as accurately
as possible. However, Vision Engineering Ltd. will not be
responsible for the accuracy of the information contained
in this document, which is used at your own risk and
should not be relied upon. The information included in
this manual may be changed without prior notice.

Contents
System equipment
Stand & objectives 1
Swift PRO Cam 1
Stage 1
Head 2
QC 3000 2
Controller 2
Assembly
Removing the transit protection 3
Attaching the lens mount 3
Objective lens attachment 3
Attaching the LED ringlight 4
Attaching the episcopic illuminator (EPI) 4
Connecting the EPI 4
Stage assembly (150mm x 100mm & 200mm x 100mm) 5
PC system connection 6
QC 3000 connection 6
Stage alignment (video systems only) 7
Securing the stage (150mm x 100mm & 200mm x 100mm) 7
Head attachment 8
Fitting the stage glass 8
Stage glass levelling 9
Anti-glare shield attachment 9
Operation & setup
Main system controls 10
Getting the most from your system 11
Routine maintenance 11
Environmental considerations 11
Substage illumination LED replacement (all models) 12
Graticule tting & adjustment 12
Retrotting the Z axis module 13
Optional riser block 13
Episcopic LED replacement 13
Page

Technical specications
Measuring Stage 14
Measuring Range 14
Height adjustment 14
Encoder Resolution 14
Video Camera 14
Optics (Swift PRO Duo and Elite) 14
Illumination 14
PSU fuse ratings 14
Dimensions 14
Swift PRO Duo and Elite 14
Swift PRO Cam 14
Service & calibration record
Serial numbers 15
Service information 15
Warranty

System equipment
www.visioneng.com/support
1
System equipment
Stand & objectives
Stand
Lens mount
Lens options
Illuminator options
Toolkit
Anti-glare shield
Z Axis upgrade kit
(optional)
Swift PRO Cam
Stage
150mm x 100mm manual stage
OR
200mm x 100mm manual stage

System equipment
www.visioneng.com/support
2
Head
QC 3000
Controller
PC
Monitor
Keyboard and mouse

Assembly
www.visioneng.com/support
3
Assembly
Removing the transit protection
`Remove the two securing screws uand then remove the
transit plate v.
Keep the transit protection for future transport of
your system.
It is highly recommended that you ret the transit
protection whenever you transport your system.
Attaching the lens mount
`Insert the lens mount uup into the focus assembly v
and secure it with the securing grub screw w.
Objective lens attachment
`With the lens mount uin place (see above).
`Place the objective lens vup into the lens mount and
screw it into position.
u
v
v
u
w
v
u

Assembly
www.visioneng.com/support
4
Attaching the LED ringlight
`Locate the LED ringlight uinto position over the lens
mount vand tighten the securing screws w.
For connection details, see page 6.
Attaching the episcopic illuminator (EPI)
`Locate the cone uover the EPI vand secure it with
the grub screw w.
`Locate the EPI into the focus assembly xand secure it
with the grub screw y.
Connecting the EPI
`Insert the appropriate end of the connection lead u
into the EPI connector vand then connect the other
end of the lead wto the connector xon the underside
of the focus assembly y.
u
w
v
y
u
v
w
x
w
x
v
u
y
Questo manuale è adatto per i seguenti modelli
3
Indice
Altri manuali Vision Engineering Strumento di misura