Voltech PM1000+ Manuale utente

PM1000+ Power Analyzer User Manual © Voltech 2007 Page I
PM1000+
POWER ANALYZER
USER MANUAL
V
oltech Instruments Inc.
11637 Kelly road, Suite 306
Fort Myers, FL33908
U.S.A.
Tel: 239 437 0494
Fax: 239 437 3841
V
oltech Instruments Ltd.
148 Harwell Business Centre
Didcot, Oxon, OX11 0RA
U.K.
Tel: +44 1235 834555
Fax: +44 1235 835016
www.voltech.com
Need help?
Thank you for choosing to use this Voltech Power Analyzer. It has
been designed to be safe and easy to use.
Should you experience any difficulty during the set up or use of an
y
Voltech product, or are unsure of any of their features or abilities,
please do not hesitate to contact either your local supplier or visit
our applications support center at www.voltech.com

Page II © Voltech 2007 PM1000+ Power Analyzer User Manual
Voltech Instruments is committed to a policy of continuous product development.
Hence product specification and the information given in this manual are subject to
change without notice.
No part of this publication may be reproduced, stored in a retrieval system, or
transmitted in any form, or by means electronic, mechanical photocopying,
recording or otherwise, without prior written permission of Voltech Instruments.
2007 Voltech Instruments. All rights reserved.
Microsoft, Windows and the Windows logo are either registered trademarks or
trademarks of Microsoft Corporation in the United States and/or other countries.
Voltech Part Number: 98-115
Manual Issue PM1000+ Firmware Revision
1 V4.07
For the latest version of the manual and firmware please see our website at
www.voltech.com

PM1000+ Power Analyzer User Manual © Voltech 2007 Page III
DANGER OF ELECTRIC SHOCK
Only qualified personnel should install this equipment, after reading and
understanding this user manual. If in doubt, consult your supplier.
RISQUE D'ELECTROCUTION
L'installation de cet équipement ne doit être confiée qu'à un personnel
qualifié ayant lu et compris le présent manuel d'utilisation. Dans le
doute, s'adresser au fournisseur.
GEFAHR VON ELEKTRISCHEM SCHOCK
Nur entsprechend ausgebildetes Personal ist berechtigt, diese
Ausrüstung nach dem Lesen und Verständnis dieses
Anwendungshandbuches zu installieren. Falls Sie Zweifel haben sollten,
wenden Sie sich bitte an Ihren Lieferanten.
RISCHIO DI SCARICHE ELETTRICHE
Solo personale qualificato può installare questo strumento, dopo la
lettura e la comprensione di questo manuale. Se esistono dubbi
consultate il vostro rivenditore.
IMPORTANT: Please consult the safety information section of this user manual before
installation and use.
!
!
!
!

Page IV © Voltech 2007 PM1000+ Power Analyzer User Manual

PM1000+ Power Analyzer User Manual © Voltech 2007 Page V
Contents
1. Introduction ............................................................................................... 1-1
1.1. Features & Abilities ......................................................................................... 1-1
1.2. Package Contents........................................................................................... 1-2
1.3. Accessories .................................................................................................... 1-2
2. Quick Start................................................................................................. 2-1
2.1. Power On........................................................................................................ 2-1
2.2. Connecting to the Product Under Test ............................................................ 2-2
2.3. Default Measurements.................................................................................... 2-3
2.4. Navigating the Menu System .......................................................................... 2-4
2.5. Menu Keys...................................................................................................... 2-5
2.6. Example: Choosing Measurements to Display ................................................ 2-5
2.7. Key Shortcuts: ................................................................................................ 2-6
3. Using Voltage and Current Transducers................................................. 3-1
3.1. Input Overview................................................................................................ 3-1
3.2. To connect a Simple Current transfomer......................................................... 3-2
Scaling........................................................................................................... 3-2
3.3. To connect an external resistive shunt: ........................................................... 3-3
3.4. To connect a transducer with a voltage output ................................................ 3-5
3.5. To connect a Voltage Transformer / Transducer ............................................. 3-6
Scaling........................................................................................................... 3-6
4. The Menu System...................................................................................... 4-1
4.1. Navigation....................................................................................................... 4-1
4.2. Menu Items..................................................................................................... 4-1
4.3. Main Menu ...................................................................................................... 4-1
4.4. Measurements. ............................................................................................... 4-1
4.5. Modes............................................................................................................. 4-2
Select Mode................................................................................................... 4-2
Ballast Setup.................................................................................................. 4-2

Page VI © Voltech 2007 PM1000+ Power Analyzer User Manual
Inrush Setup .................................................................................................. 4-2
Standby Power Setup .................................................................................... 4-3
Integrator Setup ............................................................................................. 4-3
4.6. Inputs.............................................................................................................. 4-3
Fixed/Auto Ranging ....................................................................................... 4-3
Scaling........................................................................................................... 4-3
Frequency Source.......................................................................................... 4-4
Shunts ........................................................................................................... 4-4
Blanking......................................................................................................... 4-4
4.7. Graphs............................................................................................................ 4-4
Waveform Graph............................................................................................ 4-5
Harmonic Bar Chart ....................................................................................... 4-5
Integration Graph ........................................................................................... 4-5
4.8. Interfaces........................................................................................................ 4-5
RS232 Baud Rate.......................................................................................... 4-5
GPIB Address ................................................................................................ 4-6
4.9. User Configuration. ......................................................................................... 4-6
4.10. System Configuration.................................................................................... 4-6
Auto Zero....................................................................................................... 4-6
Clock Setup ................................................................................................... 4-6
4.11. View.............................................................................................................. 4-7
Zoom ............................................................................................................. 4-7
Contrast ......................................................................................................... 4-7
5. Remote Operation .....................................................................................5-1
5.1. Overview......................................................................................................... 5-1
5.2. Command Listing............................................................................................ 5-1
5.3. Communications examples. ............................................................................ 5-5
Basic selection and returning of result............................................................ 5-5
Harmonics...................................................................................................... 5-6
Standby power ............................................................................................... 5-6
Inrush............................................................................................................. 5-7
6. Specification..............................................................................................6-1

PM1000+ Power Analyzer User Manual © Voltech 2007 Page VII
6.1. Mechanical...................................................................................................... 6-1
6.2. Power Supply.................................................................................................. 6-1
6.3. Communications ............................................................................................. 6-1
RS232............................................................................................................ 6-1
AUX/TRIG...................................................................................................... 6-2
GPIB .............................................................................................................. 6-2
USB ............................................................................................................... 6-2
6.4. Measured Parameters..................................................................................... 6-3
6.5. Measurement Accuracy .................................................................................. 6-5
7. Warranty, Service and Updates ............................................................... 7-1
7.1. Warranty ......................................................................................................... 7-1
7.2. Calibration and Service................................................................................... 7-1
7.3. Obtaining Service and Applications Support ................................................... 7-2
7.4. Updating Firmware.......................................................................................... 7-2
8. Safety Information..................................................................................... 8-1
8.1. Safety Features .............................................................................................. 8-1
8.2. Safety Instructions .......................................................................................... 8-1
8.3. Declaration of Conformity................................................................................ 8-2

Page VIII © Voltech 2007 PM1000+ Power Analyzer User Manual

INTRODUCTION
PM1000+ Power Analyzer User Manual © Voltech 2007 Page 1-1
1. INTRODUCTION
1.1. FEATURES & ABILITIES
The Voltech PM1000+ is a powerful and versatile precision power analyzer. Designed
to provide clear and accurate measurements of electrical power and energy on all
electrical products, the PM1000+ is both an easy to use bench instrument and a fast
and programmable automatic test interface.
Basic Features:
• Measures Watts, Volts, Amps, Volt-Amperes and Power Factor.
Always accurate, even on distorted waveforms.
• Range of measurement from milli-watts to mega-watts.
• Built-in energy analyzer (watt-hour integrator) for measuring energy
consumption over time.
• Standby power measurement mode for fast and accurate low power
measurements.
• Harmonic analyzer with built in spectrum display
• Bright color display
• Comprehensive range of computer interfaces including RS232, IEEE488 and
USB
• Inrush current measurement mode for measuring switch-on and other transient
peak currents.
• Ballast mode for measuring the tube power of electronic ballasts.
• Easy-to-use menu system with context-sensitive help.

INTRODUCTION
Page 1-2 © Voltech 2007 PM1000+ Power Analyzer User Manual
1.2. PACKAGE CONTENTS
The following items are supplied with your PM1000+.
Please check that you have every item and report any missing items to your Voltech
supplier as soon as possible
• PM1000+ Power Analyzer
• Certificate of Conformance and Calibration
• CD including user’s manual and calibration data
• Mains power cable
• 2 pairs of yellow and black measuring leads
1.3. ACCESSORIES
Please see our website at www.voltech.com for accessories available from Voltech
and other suppliers. These include:
• Spare measuring lead set (part number 78-124)
• A range of current transformers to extend the measuring range from
<1mA to 3000A
• Connectors for the 2mm external shunt input
Part numbers 78-128 (red) and 78-129 (black).
• Communications leads (RS232, USB…)
Altri manuali per PM1000+
1
Indice
Altri manuali Voltech Strumento di misura