I
DC Variable-Frequency 3D Barrier Gate
SCB02 (DC24V)
Manual
V1.0.1

I
Preface
Symbol Stipulations
The meanings of the following symbols which may appear in this manual
Symbols
Meanings
Indicates that there is a high level of potential danger, if not
avoided, it may cause casualties or serious injures.
Indicates that there is a medium or low level of potential
danger. If not avoided, it may cause minor or moderate
injury to personnel.
Indicates potential risks. If you ignore the information, it
may cause equipment damage, data loss, equipment
performance degradation, or unpredictable results.
Indicates that it can help you solve a problem or save your
time.
Indicates that it is the additional information of the main
text, which emphasizes and supplements the main text.
Revision Records
Version No.
Revision Content
Release Date
V1.0.0
First Release
2022.02
Safety Instructions
The following is the correct methods of using the product, in order to prevent danger, prevent
property damage, etc., please read this manual carefully before using the equipment and strictly
follow it during use. Please keep the manual properly after reading.
Operating Environment Requirements
Please transport, use and store the device within the allowable humidity and temperature range.
Please do not let any liquid flow into the device.
Please install the device in a well-ventilated place, and do not block the vents of the device.
Please do not press hard, vibrate violently or soak the equipment.
Please use the factory packaging or materials of the same quality when shipping the equipment.
It is recommended to ground via the grounding hole on the device to improve the reliability.
Operation and Maintenance Requirements
Please do not disassemble the device privately.
Please use the accessories or attachments of the manufacturer for installation and maintenance by
professional service personnel.
Please do not provide two or more power supply methods to the device at the same time, otherwise
the device may be damaged.
The self-contained boom is not allowed to be lengthened or cut off, and it is also not allowed to add
weight to the boom privately.

Contents
Preface..........................................................................................................I
Safety Instructions........................................................................................I
1. Production Overview................................................................................1
1.1. Functions and Features......................................................................1
1.2. Technical Data...................................................................................1
2. Product Structure......................................................................................1
2.1. Mechanism Structure.........................................................................2
2.2. Running Direction Setting.................................................................3
3. Cabinet Installation...................................................................................3
4. Controller Explanations and Instructions.................................................3
4.1. Controller Interface Explanations......................................................4
4.2. Controller Parameter Setting of Master Motor..................................6
4.3. “Regular Menu” Command List of Master Motor.............................6
4.4. “Advanced Menu” Command List of Master Motor.......................12
4.5. Controller Parameter Setting of Slave Motor..................................15
4.6. “Regular Menu” Command List of Slave Motor.............................16
4.7. “Regular Menu” Command Explanation.........................................17
4.8. “Advanced Menu” Command List of Slave Motor.........................19
4.9. “Advanced Menu” Command Explanation.....................................20
5. Common Malfunctions and Solutions....................................................21
6. Warranty and Service Items....................................................................23
7. Maintenance............................................................................................24
8. Packing List............................................................................................24

1
1. Production Overview
1.1. Functions and Features
1.1.1. Adopting the three-dimensional double-drive no-spring mechanism
independently developed.
1.1.2. Dual power motors, use two-stage planetary gear and two-stage gear drive
combination respectively, rotate up and down and horizontally, and superimpose to
form a three-dimensional surface running track.
1.1.3. Adopting DC permanent magnet synchronous motor and variable-frequency
control, effectively solve the problems of limited speed, life and spring.
1.1.4. Breaking the normal operation mode of the barrier gate, the starting point
adopts the same-direction driving operation mode with the vehicle passing, to realize
the ultra-high-speed and ultra-intensive operation.
1.1.5. The boom will be reset after hit and removed, which effectively protects the
boom and the mechanism, alarm against abnormal lifting boom.
1.1.6. Be able to stop at any position in three-dimensional space, no longer limited
height problem.
1.1.7. Double protection, one drive failure will not affect the other drive, and the
barrier gate can still operate in another space;
1.1.8. No spring design, no longer worry about configuring springs and springs
broken.
1.1.9. Traffic lights on the top cover to better indicate the passage of vehicles.
1.1.10. The running direction can be easily changed in two steps.
1.1.11 The cabinet is round hollow-out design, with smooth lines and intuitive
movement process.
1.1.12. Equipped with carbon fiber foam round boom, to effectively protect the
vehicle.
1.1.13. Large LCD screen display, English visual menu, easy function selection and
debugging.
1.1.14. Support external radar, coil, infrared anti-smashing function, built-in DC 12V
power output, can be used for external radar power supply.
1.1.15. Support RS485 communication or RS485 off-line connection.
1.1.16. DC12V power supply is optional.
1.2. Technical Data
1.2.1. Working temperature (motor): -35℃~ + 70℃
1.2.2. Power supply input voltage: AC110±10%, AC220V±10%

2
1.2.3. Controller input voltage: DC24V±10%, 10A
1.2.4. Motor power: up and down power 180W; horizontal power 60W
1.2.5. Relative Humidity: 30%~80%, No condensation
1.2.6. Distance of remote control: L≥30M
1.2.7. Running Speed: 0.3 seconds MAX
1.2.8. MTBF: 8,000,000 times
2. Product Structure
2.1. Mechanism Structure

3
2.2. Running Direction Setting
3. Cabinet Installation
According to the specific conditions of the site, select the barrier gate of the
appropriate specification, and use the expansion bolts to fix the cabinet on the ground
with 4 sets M16*150 expansion bolts. At the location where the cabinet is installed,
the barrier foundation should be made according to the site conditions, and the
cast-in-place foundation should be made for the non-concrete ground.
4. Controller Explanations and Instructions
All the electrical connections are done before delivery. The necessity is to connect the
power and grounding connection.

4
4.1. Controller Interface Explanations
Item
Explanation
Wire Control
Interface
This interface is available for parking system, also available for
external controller to control barrier gate.
UP: Short circuit “UP” and “GND”
Down: Short circuit “Down” and “GND”
Stop: Short circuit “Stop” and “GND”

5
Item
Explanation
Anti-smashing
Interface
Infrared Photocell: boom will lift up when short circuiting
“Infrared photocell interface” and “GND” during boom down.
Loop Detector: boom will lift up when short circuiting “loop
detector interface” and “GND” during boom down; in up limit
position, boom will fall down automatically after these two
interfaces disconnected.
RS485
communication
interface
It is used for controlling the barrier gate or checking the status of
the barrier gate by computer or system; also used for online
controlling the paired barrier gates synchronously.
Limit Relay
Output
Interface
It is used for the system to checking the status of the barrier gate
by the opening and closing times; users can also change to other
output modes via option 4 of the advanced menu.
DC12V Power
Output
Provide 1A current output, available for radar or small light strips.
Interface for
R&G lights
Available to connect with R&G lights, to indicate the working
status of the barrier gate.
Buttons of
Mater Motor
The 4 buttons have two working status: normal working status
and menu setting status, the function of normal working status is
that “▲” is the opening function, “▼” is the closing function, (in
normal working status of slave motor also link-able to open and
close), “■” is the stopping function, “ 三” is the setting function
which is invalid when it is short pressed under normal working
status; Long press “ 三” for 2 seconds to enter the menu setting
status. In the menu setting status, “▲” and “▼” are used to adjust
menu items or parameters, “■” is to cancel the set value or exit
the menu setting status, “ 三” is used to enter the next menu or
save the set value. (Note: These buttons can only set the menu of
master motor)

6
Item
Explanation
Buttons of
Slave Motor
The 4 buttons have two working status: normal working status
and menu setting status, the function of normal working status is
that “▲/+” is the opening function, “▼/-” is the closing function,
“■QUIT” is the stopping function, “ ” is the setting function
which is invalid when it is short pressed under normal working
status; Long press “ ” for 2 seconds to enter the menu setting
status. In the menu setting status, “▲/+” and “▼/-” are used to
adjust menu items or parameters, “■QUIT” is to cancel the set
value or exit the menu setting status, “ ” is used to enter the
next menu or save the set value. (Note: These buttons can only set
the menu of slave motor)
LCD Screen
It is used to display the information of the master motor of the
barrier gate, such as the working status, parameters, menu items.
LED Digital
Tube
It is used to display the information of the slave motor of the
barrier gate, such as the working status, parameters, menu items.
4.2. Controller Parameter Setting of Master Motor
Long press “三” button for 2 seconds to enter the regular menu setting status. Select
menu items by short press or long press "▲" and "▼" buttons, short press once to
increase or decrease by one, long press to continuously increase or decrease. When
the required diameter displayed by the LCD, press “ 三” button again to enter the
setting of the specified item, and press the "■" to return to the previous level or exit
the setting. When the specified parameter setting is completed, you must press "三"
button to confirm it to take effect. The currently set parameters is invalid if pressing "
■" button.
The recommended range specifically refers to the 2m carbon fiber boom.
4.3. "Regular Menu" Command List of Master Motor
4.3.1. Opening operation parameters
Sub-menu
Defaults
Range
Recommended
Values
Remarks
1.1 Acceleration Time
3
1-20
≥3
The smaller the
value, the faster the
speed

7
1.2 Opening Speed
100
15-100
90-100
The bigger the
value, the faster the
opening speed
1.3 Deceleration Angle
65
10-80
60-70
The angle at which
deceleration begins
in the opening
process; if the boom
shakes after it is
opened in place,
users can reduce this
value.
1.4 Angle of Low-speed
Area
90
45-90
90
The angle at which
the boom enters a
low-speed area in
the opening process;
if the boom shakes
after it is opened in
place, users can
reduce this value.
1.5 End Speed
8
1-50
6-8
The minimum speed
at which the barrier
gate is opened in
place; if the boom
shakes after it is
opened in place,
users can reduce this
value.
1.6 Learning Speed
25
10-50
25
The speed at which
the the barrier gate
begins to learn the
up limit position
after the power is
turned on for the
first time.
4.3.2. Closing operation parameters