Installation Guide
1. What's in the Box Page 1
2. Safety Precaution Pages 2,3
3. Electrical Specifications Page 4
4. Load Compatibility details Page 5
5. Installing your new WiCave home Pages 6-10
6. Configuring your system Pages 11-12
7. Trouble Shooting Pages 13

What’s in the box
Inside the box you will find the following;
1 x Assembled Wi cave module
10 x Wires 1 feet each
10. Ferrules ( L,N, 1-4, A-D)
2 x Screws
2 x Wall Plugs
Installation & User Manual
Contact Us:
Call: 99702 84513 ; Email: info@wicave.com ; Web site: www.wicave.com
1
2
3
4
5
Congratulations and thank you for purchasing WiCave Home. The following product
description will provide you with useful information about its use.

Contact Us:
Call: 99702 84513 ; Email: info@wicave.com ; Web site: www.wicave.com
Safety Precautions:

Safety Precautions:
Contact Us:
Call: 99702 84513 ; Email: info@wicave.com ; Web site: www.wicave.com
•Please comply strictly with the following instructions which are intended to ensure safe
operation of the controller.
•Application of voltages other than the rated voltage may seriously damage the internal
elements
•Separate the WiCave Module from any potential sources of noise, such as high-voltage
lines. When using inductive loads(e.g., electromagnetic relays), connect noise-
absorbing elements (resistor and capacitor) to both ends of the coil.
•Do not install the module close to sources of excessive static electricity (e.g., forming
compounds, powders, or fluid materials being transported by pipe). Locations subject
to temperatures or humidity outside the range specified in the specifications.
•Do not use the WiCave Module in dusty environments, in locations where corrosive
gases are present, or in locations subject to direct sunlight.
•This product is not waterproof or oil-proof. Do not use it in locations where water or oil
may enter the product interior.
•Take adequate protective measures for the power supply of the Time Switch (such as
providing a breaker and fuse).

Electrical specifications:
Contact Us:
Call: 99702 84513 ; Email: info@wicave.com ; Web site: www.wicave.com
AC SPECIFICATIONS
Operating Input Power Range 90VAC-264VAC±5%, 47-63Hz, 5A Max.
Maximum Load per Node. 200W Resistive Load @ 230VAC input.
150VA Inductive Load @ 230VAC input.
Dimmer Output power for Inductive Loads 10VA – 150VA @ 230VAC.
GENERAL SPECIFICATIONS
Power Consumption <0.2W no load <1.0W Loaded.
Temperature Operation 0°C to +50°C.
Storage -20°C to +70°C.
Relative Humidity Operating 5%RH to 95%RH Non-Condensing.
Storage 5%RH to 95%RH Non-Condensing.
Dimension 80mm x 50mm x 25mm
RF Frequency 2.45GHz
Enclosure ABS Plastic FR Grade.

Load Compatibility details:
Contact Us:
Call: 99702 84513 ; Email: info@wicave.com ; Web site: www.wicave.com
Types of loads compatible with WiCave home:
•-Each WI cave Home module is capable of handling 4 loads.
•WiCave Home enables ON/OFF loads and also it can regulate speed of fan or
control intensity of dimmable type lamps.
•A : Light sources(CFL, LED lamps, etc),, Television, Desktop computer and other
utility appliances.
•B: Speed controlled /Dimmable loads: Incandescent lamps, halogen lamps,
dimmable CFL lamps, dimmable LED lamps, dimmable ceiling fans and other
dimmable resistive and inductive loads.
Module Connector Details &
Load data :
N- NEUTRAL
L- LINE
1- LOAD 1
2- LOAD 2
3- LOAD 3
4- LOAD 4
A-SWITCH 1
B-SWITCH 2
C-SWITCH 3
D-SWITCH 4
N
L
1
2
3
4
A
B
C
D

Installing your new WiCave Module
•Warning: If you are not confident with electrical wiring please call WiCave
representative or your local electrician.
Contact Us:
Call: 99702 84513 ; Email: info@wicave.com ; Web site: www.wicave.com
•1. Locate and turn OFF all circuit breakers associated with your
Switchboard system in which the WiCave module is to be installed.
2. Check the Wi-Fi signal strength at the switch board, signal strength
should greater than 75%.If it is less than 75% then, and adjust the router
near to the switch board.
•3. Open the switchboard top cover. Assure there is no
power using a line tester.
•4. Identify Line and neutral wires .
•5. Identify the loads to which the module is to be connected.
•6. Disconnect the loads from the respective switches.

Installing your new WiCave Module:
Contact Us:
Call: 99702 84513 ; Email: info@wicave.com ; Web site: www.wicave.com
Identify the type of wiring in your switchboard and wire as follows:
Switch board wiring after Installation of Wicave module
Case-1: Common Live to Switch
Switch board wiring Before Installation of Wicave module
SWITCH
1
SWITCH
2
SWITCH
3
SWITCH
4
Line
230 VAC
LOAD 1
LOAD 2
LOAD 3
LOAD 4
Neutral
230 V AC
NL
A
B
C
D
SWITCH
1
SWITCH
2
SWITCH
3
SWITCH
4
Line
230 VAC
LOAD 1
LOAD 2
LOAD 3
LOAD 4
Neutral
230 V AC
4
3
2
1
Wicave Module

Installing your new WiCave Module:
Contact Us:
Call: 99702 84513 ; Email: info@wicave.com ; Web site: www.wicave.com
Identify the type of wiring in your switchboard and wire as follows:
Switch board wiring after Installation of Wicave module
Case-2: Common Neutral to switch
Switch board wiring Before Installation of Wicave module
SWITCH
1
SWITCH
2
SWITCH
3
SWITCH
4
Neutral
230 VAC
LOAD 1
LOAD 2
LOAD 3
LOAD 4
Line 230
V AC
NL
A
B
C
D
SWITCH
1
SWITCH
2
SWITCH
3
SWITCH
4
Neutral23
0 VAC
LOAD 1
LOAD 2
LOAD 3
LOAD 4
Line
230 V AC
4
3
2
1
Wicave Module
Indice