Pressure switch, model PSD-4
Pressure switch, model PSD-4
Druckschalter, Typ PSD-4
Pressostat, type PSD-4
Presostato, modelo PSD-4
MAKGIL VIET NAM

2WIKA operating instructions pressure switch, model PSD-4
EN
DE
FR
ES
14208834.01 07/2017 EN/DE/FR/ES
© 07/2017 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!
Betriebsanleitung Typ PSD-4 Seite 35 - 66
Operating instructions model PSD-4 Page 3 - 34
Mode d‘emploi type PSD-4 Page 67 - 98
Manual de instrucciones modelo PSD-4 Página 99 - 131
MAKGIL VIET NAM

14208834.01 07/2017 EN/DE/FR/ES
3WIKA operating instructions pressure switch, model PSD-4
EN
Contents
Declarations of conformity can be found online at www.wika.com
Contents
1. General information 4
2. Design and function 5
3. Safety 7
4. Transport, packaging and storage 10
5. Commissioning, operation 11
6. Faults 21
7. Maintenance and cleaning 24
8. Dismounting, return and disposal 25
9. Specications 27
10. Accessories and spare parts 34
MAKGIL VIET NAM

14208834.01 07/2017 EN/DE/FR/ES
4WIKA operating instructions pressure switch, model PSD-4
EN
1. General information
1. General information
■
The instrument described in the operating instructions has been designed and manufactured using state-of-the-
art technology. All components are subject to stringent quality and environmental criteria during production. Our
management systems are certied to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on handling the instrument.Working safely requires that
all safety instructions and work instructions are observed.
■
Observe the relevant local accident prevention regulations and general safety regulations for the instrument's range
of use.
■
The operating instructions are part of the product and must be kept in the immediate vicinity of the instrument and
readily accessible to skilled personnel at any time. Pass the operating instructions on to the next operator or owner
of the instrument.
■
Skilled personnel must have carefully read and understood the operating instructions prior to beginning any work.
■
The general terms and conditions contained in the sales documentation shall apply.
■
Subject to technical modications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: PE 81.86
- Application consultant: Tel.: +49 9372 132-0
Fax: +49 9372 132-406
MAKGIL VIET NAM

14208834.01 07/2017 EN/DE/FR/ES
5WIKA operating instructions pressure switch, model PSD-4
EN
2. Design and function
2. Design and function
2.1 Scope of delivery
■
Pressure switch
■
Operating instructions
■
Test report
Cross-check scope of delivery with delivery note.
2.2 Overview
INFO button
Digital indicator
Status display, switching outputs
MENU button
Confirmation button
Electrical connection
Process connection, spanner flats
Process connection, thread
MAKGIL VIET NAM

14208834.01 07/2017 EN/DE/FR/ES
6WIKA operating instructions pressure switch, model PSD-4
EN
4-digit LED display
■
Display of pressure value
■
Display of menu item
■
Display of parameter
Status of switching output 1
Status of switching output 2 (optional)
Display mode
▶Short press
Display of unit
▶Long press
Display of the set parameters, see
chapter 5.7 “Parameters”
Programming mode
▶Short press
Menu up
Parameter value up (step-wise)
▶Long press
Menu up
Parameter value up (fast)
Display mode
▶Short press
Display of unit
▶Long press
Jumping into the programming mode
Programming mode
▶Short press
Menu down
Parameter value down (step-wise)
▶Long press
Menu down
Parameter value down (fast)
Display mode
▶Short press
Display of unit
Programming mode
▶Short press
Selection of menu item
Conrmation of input
2.3 Display and operating unit
2. Design and function
MAKGIL VIET NAM

14208834.01 07/2017 EN/DE/FR/ES
7WIKA operating instructions pressure switch, model PSD-4
EN
3. Safety
3. Safety
3.1 Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or damage to property or the
environment, if not avoided.
WARNING!
... indicates a potentially dangerous situation that can result in burns caused by hot surfaces or liquids,
if not avoided.
Information
... points out useful tips, recommendations and information for ecient and trouble-free operation.
3.2 Intended use
The instrument has been designed and built solely for the intended use described here, and may only be used
accordingly.
The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use.
Intended use
The PSD-4 pressure switch is used for the switching of circuits as a function of the measured pressure. In addition, the
pressure value can be output to appropriate read-out units as a standardised analogue signal.The switching conditions
can be programmed directly at the pressure switch (switch and reset points, ...). Via the dierent display elements,
switching statuses and pressure values can be read.
This is a class B instrument for emissions and is intended for use in industrial environments. In other environments,
e.g. residential or commercial installations, it can intefere with other equipment under certain conditions. In such
circumstances the operator is expected to take the appropriate measures.
MAKGIL VIET NAM

14208834.01 07/2017 EN/DE/FR/ES
8WIKA operating instructions pressure switch, model PSD-4
EN
Application areas
Only use the pressure switch in applications that lie within its technical performance limits (e.g. max. ambient
temperature, material compatibility, ...).
→ For performance limits see chapter 9 “Specications”.
Technical restrictions
■
The overload pressure must never be exceeded, even when failures occur in the end-use application. Loadings
above the overload safety can cause measuring errors.
■
Pressure surges below the nominal pressure and shorter than 1 ms can cause measuring errors.
■
For applications where pressure spikes can occur, the use of a restrictor is recommended.The restrictor narrows the
pressure port to 0.3 mm and thus increases the resistance against pressure spikes.
■
With media that could block the pressure port (e.g. through particles), a ush instrument version must be used.
■
With a high ambient temperature and a high UV irradiation, the pressure switch must be installed with additional
covering in order to avoid damage to the digital indicator and buttons.
■
The medium temperature at the instrument must not exceed 85 °C. With hotter media, a cooling element can
provide a solution (see chapter 10 “Accessories and spare parts”).
3.3 Personnelqualication
Skilled personnel
Skilled personnel, authorised by the operator, are understood to be personnel who, based on their technical training,
knowledge of measurement and control technology and on their experience and knowledge of country-specic regula-
tions, current standards and directives, are capable of carrying out the work described and independently recognising
potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive media.
3. Safety
MAKGIL VIET NAM

14208834.01 07/2017 EN/DE/FR/ES
9WIKA operating instructions pressure switch, model PSD-4
EN
3. Safety
3.4 Use of accessories and spare parts
It is recommended to use original accessories and original spare parts from WIKA. Using accessories and spare parts
from third parties can lead to damage to the instrument or accidents, due to quality defects or other reasons.
WIKA assumes no liability for damage or accidents caused by a malfunction or unsuitability of accessories and spare
parts which do not originate from WIKA (e.g. non-compliance with the IP ingress protection of connectors). No warranty
claims can be made which arise due to a malfunction or unsuitability of any accessory or spare part from a third party.
3.5 Labelling, safety marks
Product label
If the serial number becomes illegible (e.g. due to mechanical damage or overpainting), traceability will no longer be
possible.
S# Serial no. Pin assignment and specications
P# Product no. Approvals
Measuring range Coded date of manufacture
IO-Link version (option)
Symbols
Before mounting and commissioning the instrument, ensure you read the operating instructions!
www.wika.com Made in Germany
PSD-4
MAKGIL VIET NAM

14208834.01 07/2017 EN/DE/FR/ES
10 WIKA operating instructions pressure switch, model PSD-4
EN
4. Transport, packaging and storage
4. Transport, packaging and storage
For the protection of the diaphragm, the ush design is delivered with a special protection cap.
▶
In order to avoid damage at the diaphragm and/or the process connection thread, remove the
protection cap by hand only just before installation.
▶
Keep the protection cap for subsequent storage or transport.
▶
Fit the protection cap before dismounting and transporting the instrument.
4.1 Transport
Check the pressure switch for any damage that may have been caused by transport. With ush design, additionally
check the diaphragm for any optical damage.
Obvious damage must be reported immediately.
4.2 Packaging and storage
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during transport (e.g. change in installation site, sending for
repair).
Permissible conditions at the place of storage:
■
Storage temperature: -20 ... +70 °C
■
Humidity: 45 ... 75 % relative humidity (no condensation)
In order to protect the diaphragm, mount the protection cap before storing the instrument.
MAKGIL VIET NAM
Altri manuali per PSD-4
3
Indice
Lingue:
Altri manuali WIKA Interruttore

WIKA
WIKA OLS-C Series Manuale utente

WIKA
WIKA FSD-3 Manuale utente

WIKA
WIKA Phase-Out PSD-3 Series Manuale utente

WIKA
WIKA PSD-4 Manuale dell'operatore

WIKA
WIKA OLS-C01 Manuale utente

WIKA
WIKA KSR KUEBLER BGU D Series Manuale utente

WIKA
WIKA PSD-4 Manuale utente

WIKA
WIKA TS-972 Manuale utente

WIKA
WIKA TLS Manuale utente

WIKA
WIKA FSFD Manuale utente

WIKA
WIKA TFS35 Manuale utente

WIKA
WIKA DC Series Manuale utente

WIKA
WIKA mw series Manuale utente

WIKA
WIKA RLS-7000 Manuale utente

WIKA
WIKA SERIES DW Manuale utente

WIKA
WIKA OLS-C20 Manuale utente

WIKA
WIKA OLS-F1 Manuale utente

WIKA
WIKA PS-21 Manuale utente

WIKA
WIKA PSD-4-ECO Manuale utente

WIKA
WIKA FSM-6100 Manuale utente