WIKA RLS-1000 Manuale utente

DE
EN
ES
FR
Model RLS-1000
mounting thread, angular connector
Model RLS-2000
cable outlet
Model RLS-5000
Bilge oat switch
Operating instructions
Betriebsanleitung
Mode d‘emploi
Manual de instrucciones
Float switch, models RLS-1000, RLS-2000, RLS-3000,
RLS-5000, RLS-6000
Schwimmerschalter, Typen RLS-1000, RLS-2000,
RLS-3000, RLS-5000, RLS-6000
Détecteur de niveau à otteur, types RLS-1000, RLS-2000,
RLS-3000, RLS-5000, RLS-6000
Interruptor de otador, modelos RLS-1000, RLS-2000,
RLS-3000, RLS-5000, RLS-6000

2
14235429.01 01/2018 EN/DE/FR/ES
WIKA operating instructions models RLS
DE
EN
ES
FR
Operating instructions models RLS-1000,
RLS-2000, RLS-3000, RLS-5000, RLS-6000 Page 3 - 24
Betriebsanleitung Typen RLS-1000,
RLS-2000, RLS-3000, RLS-5000, RLS-6000 Seite 25 - 46
Mode d‘emploi types RLS-1000, RLS-2000,
RLS-3000, RLS-5000, RLS-6000 Page 47 - 68
Manual de instrucciones modelos RLS-1000,
RLS-2000, RLS-3000, RLS-5000, RLS-6000 Página 69 - 89
© 01/2018 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!

EN
WIKA operating instructions models RLS
14235429.01 01/2018 EN/DE/FR/ES
3
Declarations of conformity can be found online at www.wika.com.
Contents
Contents
1. General information 4
2. Design and function 5
3. Safety 6
4. Transport, packaging and storage 11
5. Commissioning, operation 11
6. Faults 17
7. Maintenance and cleaning 18
8. Dismounting, return and disposal 19
9. Specications 20

EN
14235429.01 01/2018 EN/DE/FR/ES
4WIKA operating instructions models RLS
1. General information
■
The oat switches described in the operating instructions have
been designed and manufactured using state-of-the-art technology.
All components are subject to stringent quality and environmental
criteria during production. Our management systems are certied to
ISO 9001 and ISO 14001.
■
These operating instructions contain important information on
handling the instrument. Working safely requires that all safety
instructions and work instructions are observed.
■
Observe the relevant local accident prevention regulations and
general safety regulations for the instrument’s range of use.
■
The operating instructions are part of the product and must be kept
in the immediate vicinity of the instrument and readily accessible to
skilled personnel at any time. Pass the operating instructions on to
the next operator or owner of the instrument.
■
Skilled personnel must have carefully read and understood the
operating instructions prior to beginning any work.
■
The general terms and conditions contained in the sales
documentation shall apply.
■
Subject to technical modications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: LM 50.03 (model RLS-1000)
LM 50.04 (model RLS-2000)
LM 50.06 (model RLS-3000)
LM 50.08 (model RLS-5000)
LM 50.09 (model RLS-6000)
- Application consultant: Tel.: +49 9372 132-0
Fax: +49 9372 132-406
1. General information

EN
≤ 30°
WIKA operating instructions models RLS
14235429.01 01/2018 EN/DE/FR/ES
5
2. Design and function
2.1 Functional description
Float switches work on the oat principle with magnetic transmission.
A reed contact integrated in the guide tube is actuated through the
magnetic eld of a permanent magnet, when a preset switch point
is reached. The permanent magnet is located within a oat , which
changes its height with the level of the medium it is monitoring.The
switching status of the reed contact can be evaluated and processed by
a connected control device.
The number and arrangement of oats is dependent on the number of
the dened switch points, their contact function and also the distance
between the switch points.
Connection housing
Cable bushing
Mounting thread
Guide tube
Float stop
Float
2.2 Scope of delivery
■
Float switch
■
Operating instructions
Cross-check scope of delivery with delivery note.
2. Design and function

EN
14235429.01 01/2018 EN/DE/FR/ES
6WIKA operating instructions models RLS
3. Safety
3.1 Explanation of symbols
DANGER!
... indicates a directly dangerous situation resulting in serious
injury or death, if not avoided.
WARNING!
... indicates a potentially dangerous situation that can result
in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can result
in light injuries or damage to property or the environment, if
not avoided.
Information
... points out useful tips, recommendations and information
for ecient and trouble-free operation.
3.2 Intended use
Float switches are used exclusively for monitoring the levels of liquid
media. The scope of application is dened by the technical performance
limits and materials.
■
The liquids must not have any large contamination or coarse particles
and must not have a tendency to crystallise. Ensure that the wetted
materials of the oat switch are suciently resistant to the medium
being monitored. Not suitable for dispersions, abrasive liquids, highly
viscous media and colours.
3. Safety

EN
WIKA operating instructions models RLS
14235429.01 01/2018 EN/DE/FR/ES
7
■
This instrument is not permitted to be used in hazardous areas!
In hazardous areas, check the usability of the model RLS-4000
intrinsically safe oat switch.
■
The operating conditions specied in the operating instructions must
be observed.
■
Do not operate the instrument in the direct vicinity of ferromagnetic
environments (min. distance 100 mm).
■
Do not operate the instrument in the immediate vicinity of strong
electromagnetic elds or in the immediate vicinity of equipment that
can be aected by magnetic elds (min. clearance 1 m).
■
The oat switches must not be exposed to heavy mechanical strain
(impact, bending, vibration).
■
The technical specications contained in these operating instructions
must be observed. Improper handling or operation of the instrument
outside of its technical specications requires the instrument to be
taken out of service immediately and inspected by an authorised
WIKA service engineer.
The instrument has been designed and built solely for the intended use
described here, and may only be used accordingly.
The manufacturer shall not be liable for claims of any type based on
operation contrary to the intended use.
DANGER!
Work on containers involves the danger of intoxication and
suocation. No work is allowed to be carried out unless by
taking suitable personal protective measures (e.g. respiratory
protection apparatus, protective outt etc.).
3. Safety

EN
14235429.01 01/2018 EN/DE/FR/ES
8WIKA operating instructions models RLS
3.3 Improper use
Improper use is dened as any application that exceeds the technical
performance limits or is not compatible with the materials.
WARNING!
Injuries through improper use
Improper use of the instrument can lead to hazardous
situations and injuries.
▶
Refrain from unauthorised modifications to the instrument.
▶
Do not use the instrument within hazardous areas.
Any use beyond or dierent to the intended use is considered as
improper use.
Do not use this instrument in safety or emergency stop devices.
3.4 Responsibility of the operator
The instrument is used in the industrial sector. The operator is therefore
responsible for legal obligations regarding safety at work.
The safety instructions within these operating instructions, as well as the
safety, accident prevention and environmental protection regulations for
the application area must be maintained.
To ensure safe working on the instrument, the operating company must
ensure
■
that suitable rst-aid equipment is available and aid is provided
whenever required.
■
that the operating personnel are regularly instructed in all topics
regarding work safety, rst aid and environmental protection
and know the operating instructions and in particular, the safety
instructions contained therein.
■
that the instrument is suitable for the particular application in
accordance with its intended use.
■
that following testing, improper use of the instrument is excluded.
3. Safety

EN
WIKA operating instructions models RLS
14235429.01 01/2018 EN/DE/FR/ES
9
3.5 Personnel qualication
WARNING!
Risk of injury should qualication be insucient
Improper handling can result in considerable injury and
damage to equipment.
▶
The activities described in these operating instructions
may only be carried out by skilled personnel who have the
qualifications described below.
Skilled personnel
Skilled personnel, authorised by the operator, are understood to
be personnel who, based on their technical training, knowledge
of measurement and control technology and on their experience
and knowledge of country-specic regulations, current standards
and directives, are capable of carrying out the work described and
independently recognising potential hazards.
3.6 Personal protective equipment
The personal protective equipment is designed to protect the skilled
personnel from hazards that could impair their safety or health during
work.When carrying out the various tasks on and with the instrument,
the skilled personnel must wear personal protective equipment.
Follow the instructions displayed in the work area regarding
personal protective equipment!
The requisite personal protective equipment must be provided by the
operating company.
3. Safety

EN
14235429.01 01/2018 EN/DE/FR/ES
10 WIKA operating instructions models RLS
3.7 Labelling, safety marks
Product label (example)
3. Safety
Model
P# product number
S# serial number
Electrical connection
Before mounting and commissioning the instrument, ensure
you read the operating instructions!
Questo manuale è adatto per i seguenti modelli
4
Indice
Lingue:
Altri manuali WIKA Interruttore

WIKA
WIKA FSD-3 Manuale utente

WIKA
WIKA TSD-30 Manuale utente

WIKA
WIKA TLS Manuale utente

WIKA
WIKA PSD-4 Manuale utente

WIKA
WIKA FSD-4 Manuale utente

WIKA
WIKA DC Series Manuale utente

WIKA
WIKA TSD-30 Manuale utente

WIKA
WIKA APW SERIES Manuale utente

WIKA
WIKA TFS35 Manuale utente

WIKA
WIKA PSM-700 Manuale utente

WIKA
WIKA OLS-C01 Manuale utente

WIKA
WIKA TFS135 Manuale utente

WIKA
WIKA PSD-4 Manuale utente

WIKA
WIKA KSR HLS Manuale utente

WIKA
WIKA LSD-30 Manuale utente

WIKA
WIKA FSFD Manuale utente

WIKA
WIKA PS-21 Manuale utente

WIKA
WIKA A2G-45 Manuale utente

WIKA
WIKA RLS-7000 Manuale utente

WIKA
WIKA TFS135 Manuale utente