Xtreme V80 Series Guida

V80 Value Series Pure Sine Wave
Line Interacve UPS
700VA, 1000VA, 1500VA, 2000VA Models
User & Installaon Manual
www.xpcc.com | © 2022 Xtreme Power Conversion Corporaon. All rights reserved. (Rev 7/6/22)

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 2
Uninterrupble Power Supply
Table of Contents
Important Safety Warning............................................................................3
Transportaon.................................................................................................................................3
Preparaon......................................................................................................................................3
Installaon.......................................................................................................................................3
Hardware Installaon......................................................................................................................3
Maintenance, Service, and Faults...................................................................................................4
Storage........................................................................................................5
Basic Operaon............................................................................................5
Front and Top Panel Descripon......................................................................................................5
LCD Indicators..................................................................................................................................6
Troubleshoong...........................................................................................7
Fault Reference Codes....................................................................................................................8
Specicaons...............................................................................................9
Shipping List................................................................................................9
Obtaining Service.......................................................................................10
Xtreme Power Conversion Limited Warranty..............................................11
Xtreme Power Conversion Load Protecon Policy.......................................12

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 3
Uninterrupble Power Supply
Important Safety Warning
This manual contains important safety instrucons. Please read and follow all instrucons carefully during installa-
on and operaon of the unit. Read this manual thoroughly before aempng to unpack, install, or operate your
UPS.
Transportaon
• Please transport the UPS system only in the original package to protect against shock and impact.
Preparaon
• Condensaon may occur if the UPS system is moved directly from cold to warm environment. The UPS
system must be absolutely dry before being installed. Please allow at least two hours for the UPS system
to acclimate the environment.
• Do not install the UPS system near water or in moist environments.
• Do not install the UPS system where it would be exposed to direct sunlight or near heater.
• Do not block venlaon holes in the UPS housing.
Installaon
How to determine the power requirements of your equipment
1. Ensure that the equipment plugged into the baery power-supplied outlets does not exceed the UPS
unit’s rated capacity. If rated unit capacies are exceeded, an overload condion may occur and
cause the UPS unit to shut down or the fuse blow.
2. There are many factors that can aect the amount of power that your computer system will require.
For opmal system performance keep the load below 80% of the unit’s rated capacity.
Hardware Installaon Guide
1. Your new UPS may be used immediately upon receipt. However, recharging the baery for at least 8
hours is recommended to ensure that the baery’s maximum charge capacity is achieved. Charge loss
may occur during shipping and storage. To recharge the baery, simply leave the unit plugged into an AC
outlet. The unit will charge in both the on and o posion.
2. With the UPS unit o and unplugged, connect the computer, monitor, and any externally powered
data storage device.
3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet
is protected by a fuse or circuit breaker and does not service equipment with large electrical demands.
• To prevent the risk of re or electric shock, install in a temperature and humidity controlled indoor area
free of conducve contaminants. (See the specicaons for the acceptable temperature and humidity
range.)
• To reduce the risk of overheang the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit
to direct sunlight or installing the unit near heat eming appliances such as space heaters or furnaces.
• Do not aach non-computer-related items, such as medical equipment, life-support equipment, micro-
wave ovens, or vacuum cleaners to UPS.
• Do not plug the UPS input into its own output.
• Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-
containing vessels on or near the unit.
• In the event of an emergency, press the OFF buon and disconnect the power cord from the AC power
supply to properly disable the UPS.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 4
Uninterrupble Power Supply
4. Depress the power switch to turn the unit on. The LCD indicator light will illuminate and the unit will
“beep”.
5. To maintain opmal baery charge, leave the UPS plugged into an AC outlet at all mes.
6. To store your UPS for an extended period, cover it and store with the baery fully charged. Recharge
the baery every three months to ensure baery life.
Maintenance, Service, and Faults
• The UPS system operates with hazardous voltages. Repairs may be carried out only by qualied mainte-
nance personnel.
• Cauon - risk of electric shock. Even aer the unit is disconnected from the mains (building wiring outlet),
components inside the UPS system are sll connected to the baery and electrically live and dangerous.
• Before carrying out any kind of service and/or maintenance, disconnect the baeries and verify that no
current is present and no hazardous voltage exists in the terminals of high capability capacitor such as
BUS-capacitors.
• To avoid electrical shock, turn o the unit and unplug it form the AC power source before servicing the
baery.
• Only persons are adequately familiar with baeries and with the required precauonary measures may
replace baeries and supervise operaons. Unauthorized persons must be kept well away from the bat-
teries.
• Cauon - risk of electric shock. The baery circuit is not isolated from the input voltage. Hazardous volt-
ages may occur between the baery terminals and the ground. Before touching, please verify that no
voltage is present!
• Baeries may cause electric shock and have a high short-circuit current. Please take the precauonary
measures specied below and any other measures necessary when working with baeries:
»Remove wristwatches, rings and other metal objects
»Use only tools with insulated grips and handles.
• When changing baeries, install the same number and same type of baeries.
• Do not aempt to dispose of baeries by burning them. This could cause baery explosion.
• Do not open or destroy baeries. Escaping electrolyte can cause injury to the skin and eyes. It may be
toxic.
• When replacing baeries, replace with the same type and number of baeries or baery packs.
• Do not dismantle the UPS system.
• A baery can present a risk of electrical shock and high short-circuit current. The following precauons
should be observed when working on baeries:
»Remove watches, rings, or other metal objects.
»Use tools with insulated handles.
»Wear rubber gloves and boots.
»Do not lay tools or metal parts on top of baeries.
»Disconnect charging source prior to connecng or disconnecng baery terminals.
»Determine if baery is inadvertently grounded. If inadvertently grounded, remove source from
ground. Contact with any part of a grounded baery can result in electrical shock. The likelihood
of such shock can be reduced if such grounds are removed during installaon and maintenance.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 5
Uninterrupble Power Supply
Storage
1. First turn o your UPS and disconnect its power cord from the wall outlet. Disconnect all cables con
nected the UPS to avoid baery drain.
2. The UPS should be stored in a cool dry locaon.
3. Make sure the baery is fully charged before the UPS is stored.
4. For extended storage in moderate climates, the baery should be charged for 12 hours every 3
months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat it
every 2 months in high temperature locaons.
Basic Operaon
Front and Top Panel Descripon
1. Input Circuit Breaker
The circuit breaker provides opmal overload protecon.
2. AC Inlet
Connect to ulity power through the input power cord.
(IEC320 C14 for 700VA/1000VA/1500VA, IEC 320 C20 for 2000VA)
3. AC outlet
The UPS provides outlets for connected equipment to insure temporary uninterrupted operaon during
a power failure and against surges and spikes.
4. USB Port
This port allows connecon and communicaon from the USB port on the computer to the UPS unit.
5. Power On/O Buon
Press the power Buon to turn the UPS ON or OFF.
6. Seng Buon
The audible alarm can be turned o/on by pressing this buon 3s.
7. LCD Display
The LCD will display the UPS status.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 6
Uninterrupble Power Supply
Denions for Illuminated LCD Indicators
LCD Indicators
AC INPUT(Voltage)
V
OUTPUT(Voltage)
V
Inial
Line mode
Bat-mode
Baery capacity
Load capacity
Fault
Sound disable
(Press the seng key 3s to disable and enable the buzzer sound)

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 7
Uninterrupble Power Supply
Troubleshoong
Problem Possible Causes Remedy
Abnormal
Mains normal but not
works in AC mode
1. AC Input missing 1. Check AC input connecon.
2. Input Breaker is tripped 2. Unplug the power cord of the UPS then
press the circuit breaker knob.
The UPS will not turn
on.
The on/o Buon is designed to prevent
damage by rapidly turning it o and on.
Turn the UPS o. Wait 10 seconds and
then turn the UPS on.
The unit is not connected to an AC outlet. The unit must be connected to a 100-
127V 50/60Hz outlet.
The baery is worn out. Contact technical support.
Mechanical problem.
Outlets do not provide
power to equipment
Circuit breaker is tripped due to overload
Turn the UPS o and unplug at least one
piece connected equipment. Unplug the
power cord of the UPS then press the
circuit breaker knob
Baeries are discharged Allow the unit to recharge for at least 4
hours.
Unit has been damaged by a surge or spike. Contact technical support.
Alarm code A51
Site Fail:
Line and neutral conductors of UPS Input
are reversed or the Ground is disconnect-
ed.
Check the input plug and socket.
Alarm code A56
Baery low:
Baery capacity is low, UPS will turn o
soon
1. Shut o non-essenal equipment.
2. Save your data and turn o the com-
puter.
Alarm code A64
Overload:
Your equipment requires more power than
the UPS can provide.
1. Shut o non-essenal equipment.
Alarm code A68 Over Temperature 1. Shut o non-essenal equipment.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 8
Uninterrupble Power Supply
Fault Codes
Fault
Fault code E09 Output Short :
Output circuit short.
1. Shut down the UPS
2. Your aached equipment may have
problems, please remove them and check
again.
Fault code E14
Overload:
Your equipment requires more power than
the UPS can provide.
It will shutdown.
Shut o non-essenal equipment. If this
solves the overload problem, the UPS will
transfer to normal operaon.
Fault code E18 Fan fail :
Fan has been damaged.
1.Shut down the UPS
2.Replace the fan
Fault code E19 Over Temperature
1. Shut down the UPS. Restart the UPS
to Check the fan for operaon and if the
venlaon hole has been covered
2. Contact technical support for repair.

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 9
Uninterrupble Power Supply
Specicaons
Shipping List
1. Line cord
2. Rack Ear
3. User manual
4. USB cable
MODEL NUMBER V80-700 V80-1000 V80-1500 V80-2000
CAPACITY Power rang 700VA (420W) 1000VA (600W) 1500VA (900W) 2000VA (1200W)
INPUT Voltage nominal 120VAC
Voltage range 82-148VAC
Frequency 50/60Hz auto sensing
OUTPUT Voltage 120VAC
Waveform Pure sine wave
Transfer me (typical) 2–6ms
Eciency Up to 96% ECO mode, 93% buck and boost mode
Harmonic distoron 2% @ 100% linear load; 5% @ 100% non-linear load
BATTERY Baery type Sealed, maintenance-free lead acid
Baery quanty & size (1) 12V 9AH (2) 12V 7AH (2) 12V 9AH (2) 12V 9AH
Charging current 1A max
Typical recharge 4 hours to 90%
PHYSICAL Dimensions (W x D x H) 17.2" x 16.1" x 3.5"
Weight 24 lbs 27.3 lbs 36.5 lbs 36.5 lbs
Line cord (removable) 6, 5-15P to C13 6, 5-20P to C19
Receptacles (8) NEMA 5–15R
ENVIRONMENT Operang temperature 32–104°F (0–40°C)
Audible noise < 40dBA < 45dBA
Altude 11,500 above sea level
APPROVALS cTUVus, RoHs
WARRANTY 3 years electronics, 3 years baery warranty (USA and Canada)
COMMUNICATIONS INTERFACE USB
INCLUDED IN BOX Line cord, tower pedestals, user manual, USB cable
AVAILABLE OPTIONS 5 year extended warranty, bypass distribuon (XBDM), power distribuon (XPDU), 4-post rail
kit, 2-post shelf kit, wall mount bracket

Xtreme Power Conversion Corporaon
V80 User’s Manual
Page 10
Uninterrupble Power Supply
Obtaining Service
If the UPS requires Service:
1. Use the TROUBLESHOOTING secon in this manual to eliminate obvious causes.
2. Verify there are no circuit breakers tripped.
3. Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem, call Xtreme
Power Conversion Corp Technical Support at 800.582.4524. Technical support inquiries can also be made at
[email protected]. Please have the following informaon available BEFORE calling the Technical Support
Department:
• Your name and address.
• The serial number of the unit.
• Where and when the unit was purchased.
• All of the model informaon about your UPS.
• Any informaon on the failure, including LED’s that may or may not be illuminated.
• A descripon of the protected equipment, including model numbers if possible.
• A technician will ask you for the above informaon and, if possible, help solve your problem over the
phone. In the event that the unit requires factory service, the technician will issue you a Return Mate-
rial Authorizaon number (RMA).
If you are returning the UPS to Xtreme Power for service, please follow these procedures:
1. Pack the UPS in its original packaging. If the original packaging is no longer available, ask the Technical Sup-
port Technician about obtaining a replacement set of packaging material. It is important to pack the UPS
properly in order to avoid damage in transit. Never use Styrofoam beads for a packing material.
2. Include a leer with your name, address, dayme phone number, RMA number, a copy of your original
sales receipt, and a brief descripon of the problem.
3. Mark the RMA number on the outside of all packages. Xtreme Power cannot accept any package without
the RMA number marked on the outside of the boxes.
4. Return the UPS by insured, prepaid carrier to the address provided by the Technician.
5. Refer to the Warranty statements in this manual for addional details on what is covered.
Questo manuale è adatto per i seguenti modelli
4
Indice
Altri manuali Xtreme UPS
Manuali UPS popolari di altre marche

Pylontech
Pylontech Victron & Pylontech US5000 Manuale utente

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manuale utente

Mecer
Mecer ME-1000-WTU Manuale utente

Mustek
Mustek PowerMust 530(B) Plus Manuale di installazione e funzionamento

Emerson
Emerson Liebert NXL series Manuale utente

MAKELSAN
MAKELSAN BOXER SERIES Manuale utente