ZKTeco ProFace X Manuale utente

Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the
actual product and the written information in this manual.
Quick Start Guide
ProFace X [TI]
Version: 1.0

1
1 Overview
8-inch Touchscreen
Camera & Palm Modules
Speaker
Reset Button
Flash
Exit
button
Auxiliary
input
AUX
AL+
AL-
NC
COM
NO
BUT
GND
SEN
GND
Alarm
Lock
Sensor
+12V Power
GND
INWD0
INWD1
Wiegand
In
Wiegand
Out
12V
GND
WD0
WD1
Network interface
RS232
RS485
12V
485B
485A
GND
TXD1
RXD1
GND
GND
GND
12V
12V
Power
interface
Tamper Switch
Near-infrared Flash
Thermal Imaging Temperature
Detection Module
Microphone (Optional)

AVOID DIRECT
SUNLIGHT
EXPOSURE
INDOOR USE
KEEP DISTANCE AVOID GLASS
REFRACTION
10ft
6.5ft
window
2
2 Installation Requirements
The installation requirements and indicators associated with temperature detection are given below:
Specification Standard Value Remark
Operating
Environment
Distance
(between face
and device)
Measurement
Accuracy
Indoor, No wind, No direct light,
16°C to 35°C(60.8°F to 95°F)
30 to 120cm (0.98ft to 3.94ft)
±0.3°C(±0.54°F)
The recommended operating
temperature is 25°C(77°F)
The recommended distance
is 80cm (2.62ft)
This Value is tested at a distance
of 80cm or 2.63ft in 25°C or
77°F environment.
Notes: The temperature detection data is for reference only, and not for any medical purpose.
Forehead Temperature Detection
Installation height: 1.55m
FOV (field of view) of the thermal
imaging device:50°
Temperature measurement
distance: 0.3m to 1.2m
Height of the face adapted for
detection: 1.2m to 2m
Installation Environment:
155CM
Indoor constant Temperature
Environment

3 Device Installation
①
②
3
① Attach the mounting template sticker to the wall, and drill holes according to the mounting
paper.
② Fix the back plate on the wall using the wall mounting screws.
③ Attach the device to the back plate.
④ Fasten the device to the back plate with a security screw.
Installation on the wall
1 2
4
1.55m
3

Installation on the barrier gate
Please pass the wire through the bracket before installation.
① Drill a hole on the barrier gate, insert the bracket into the hole and fix it with a nut.
② Adjust the angle of the device.
3 Device Installation
1
2
①
②
4

4 Standalone Installation
Alarm Smoke
detector
Lock TCP/IP
Exit button
Door sensor
Reader
PC
5 Door Sensor, Exit Button & Alarm Connection
Door sensor
Alarm power
Alarm
-
+
-+
-+
-+
Detector power
Smoke detector
Exit button
AUX
AL+
AL-
NC
COM
NO
BUT
GND
SEN
GND
GND
5

6 Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock.
The NO LOCK (normally unlocked when the power is on) is connected with 'NO' and 'COM' terminals,
and the NC LOCK (normally locked when the power is on) is connected with 'NC' and 'COM' terminals.
Take NC Lock as an example as shown below:
1) Device not sharing power with the lock
Normally Closed Lock
DC12V
DC12V
2) Device sharing power with the lock
+12V
GND
FR107
FR107
Normally Closed Lock
GND
AUX
GND
SEN
GND
BUT
NO
COM
NC
AL-
AL+
DC12V +12V
GND
GND
AUX
GND
SEN
GND
BUT
NO
COM
NC
AL-
AL+
7 Wiegand Reader Connection
Access Controller
+12V
GND
Wiegand Reader
INWD0
INWD1
12V
GND
WD0
WD1
Maximum input is 30V 3A
6

8 Barrier Connection
9 RS485 Connection
+12V
GND
GND
485+
485-
12V
485B
485A
GND
TXD1
RXD1
GND
GND
GND
12V
12V
485 reader
12V
485B
485A
GND
TXD1
RXD1
GND
GND
GND
12V
12V
Note: 485A and 485B can be connected to the Barrier gate or the 485 Reader, separately, but cannot
be connected to the gate and reader at the same time.
7

11 Ethernet Connection
Connect the device and the system over an Ethernet cable. An example is shown below:
: 192.168.1.201Default IP Address
: 255.255.255.0 Subnet mask
: 192.168.1.130IP Address
: 255.255.255.0 Subnet mask
Note: In LAN, IP Addresses of the server (PC) and the device must be in the same network segment
when connecting to the ZKBioSecurity MTD software.
Click [Comm.] > [Ethernet] > [IP Address], input the IP address and click on [OK].
10 Power Connection
Recommended power supply: 12V - 3A
To share the power with other devices, use a power supply with higher current ratings.
12V 3A DC
8

12 User Registration
Method1: Register on the device
Click > [User Mgt.] > [New User] to register a new user. The settings include entering the User ID
and Name, registering palm, face, password and user photo, setting user role and access control role.
When there is no Super Administrator set in the device, click to enter the menu. After setting the
Super Administrator, the system will request for the administrator’s verification before entering the menu.
For security purpose, it is recommended to register a Super Administrator at the first time you use
the device.
Palm Registration
Main Menu
User Mgt. User Role COMM. System
Data Mgt.Personalize Attendance
Search
Autotest System Info
Access Control
L
User Mgt.
New User
All Users
Display Style
Enroll Face
Enrolled Successfully
3
0
0
*****
New User
User ID
Name
User Role
Palm
Face
Password
User Photo
Access Control Role
Normal User
0
L
9
Altri manuali per ProFace X
3
Questo manuale è adatto per i seguenti modelli
1