ŸRecord the position and size of each Zone Damper on the record sheet in the
back of this manual
ŸThe Zone Damper cables should plug into the Control Box starting at position
number 1. The remaining cables are plugged into adjacent consecutive sockets.
7. Mounting the Touch Screen
ŸMount the Touch Screen close to the air conditioner control so they can be
programmed and monitored together.
ŸAvoid mounting in direct sunlight.
ŸThe Mounting Plate is used as a template for marking the wall before
mounting. A minimum 25mm diameter hole is required in the wall to
accommodate the socket on the back of the Touch Screen.
ŸThe Mounting Plate can be attached to a wall using or a
standard wall switch bracket. supplied fixings
5. Mounting the Control Box
ŸMount the Control Box in the roof space in a location central to all of the Zone
Dampers, ideally near a ceiling access panel.
ŸMount in a well ventilated area.
ŸThe Control Box should be screwed to the roof structure at a level to provide
easy access for the connection of wires.
DO NOT cover the Control Box with insulation
DO NOT mount below water heaters.
DO NOT mount near or below water pipes.
DO NOT mount near power cables or other sources of electrical noise.
ŸThe last step is to plug in the power cord to a standard power outlet. The
power outlet must be fitted by a licenced electrician.
DO NOT power up the Control Box until all connections are made.
6. Connecting the Zone Dampers
ŸPlug in the Zone Damper cables to the Control Box.
Touch Screen
Mounting Plate
Mounting Screw
Coms Cable
MOUNTING THE CONTROL BOX
INSTALLATION MANUAL
PLATINUM II
45
MOUNTING THE TOUCH SCREEN
Plug Coms Cable into socket on the back of
the Touch Screen, then simply push onto
the Mounting Plate so it clips into place
240VAC
Power Cord
Control Box
Zone Damper Cables
Touch Screen Cable(s)
Mounting Screw
LED light
indicates
power
NOTE: Ensure wall behind opening in
Mounting Plate is completely clear
Ø25