AEMC 1015 Manuale utente

MEGOHMMETER 1015
ENGLISH User Manual


Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC®Instruments
certifies that this instrument has been calibrated
using standards and instruments traceable to
international standards.
We guarantee that at the time of shipping your
instrument has met its published specifications.
An NIST traceable certificate may be
requested at the time of purchase, or obtained
by returning the instrument to our repair and
calibration facility, for a nominal charge.
The recommended calibration interval for this
instrument is 12 months and begins on the date of
receipt by the customer. For recalibration, please
use our calibration services. Refer to our repair
and calibration section at www.aemc.com.
Serial #: ________________________________
Catalog #: 1403.01
Model #: 1015
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Chauvin Arnoux®, Inc.
d.b.a AEMC®Instruments
www.aemc.com

Table of Contents
1. INTRODUCTION............................................................................... 3
1.1 International Electrical Symbols................................................3
1.2 DenitionofMeasurementCategories .....................................4
1.3 ReceivingYourShipment..........................................................4
1.4 OrderingInformation.................................................................4
1.4.1 AccessoriesandReplacementParts............................4
2. PRODUCT FEATURES ...................................................................... 5
2.1 Description................................................................................5
2.2 Features....................................................................................5
2.3 ControlFeatures .......................................................................6
3. SPECIFICATIONS............................................................................. 7
3.1 ElectricalSpecications ............................................................7
3.2 GeneralSpecications..............................................................8
3.3 SafetySpecications ................................................................8
4. OPERATION .................................................................................... 9
4.1 SafetyCheck(VoltageTest) .....................................................9
4.2 InsulationResistanceTesting(MΩRange) ..............................9
4.2.1 TestVoltage ..................................................................9
4.2.2 SpotTesting ................................................................10
4.2.3 RatioTesting ...............................................................10
4.2.4
TipsForSuccessfulInsulationResistanceTesting ......... 11
4.2.5 InsulationMeasurement-Connections ...................... 11
4.2.6 InsulationResistanceMeasurementsonMotors........14
4.3 Continuity................................................................................15
Measurements ........................................................................15
4.4 ResistanceMeasurements .....................................................15
5. MAINTENANCE ............................................................................. 16
5.1 Maintenance ...........................................................................16
5.1.1 Battery Test .................................................................16
5.1.2 BatteryandFuseReplacement ..................................17
5.1.3 Cleaning......................................................................17
RepairandCalibration ....................................................................18
TechnicalandSalesAssistance......................................................18
Limited Warranty .............................................................................19
WarrantyRepairs ............................................................................19

Megohmmeter Model 1015
3
CHAPTER 1
INTRODUCTION
WARNING
Thesesafety warningsareprovidedtoensurethesafetyofpersonnel
andproperoperationoftheinstrument.
• Readthisinstructionmanualcompletelyandfollowallthesafetyinfor-
mationbeforeattemptingtouseorservicethisinstrument.
• Safetyistheresponsibilityoftheoperator!
• Testsaretobecarriedoutonlyondeadcircuits!Checkforlivecircuits
beforemakingresistancemeasurements(safetycheck).
• Alwaysmakeconnectionsfromtheinstrumenttothecircuitundertest.
• Thesemegohmmetersaresourcesofhighvoltage,asisthe sample
connectedtothem.Allpersonsperformingorassistinginthetestsmust
followallsafetyprecautionstopreventelectricalshocktothemselves
andtoothers.
• AEMC considers the use of rubber gloves to be an excellent safety
practice even if the equipment is properly operated and correctly
grounded.
• When testing capacitance samples, make sure that they have been
properlydischargedandthattheyaresafetotouch.Dielectricinsula-
tionsamplesshouldbeshort-circuitedforatleastvetimestheamount
oftimetheywereenergized.
• Neveropenthebackoftheinstrumentwhileconnectedtoanycircuitor
input.
1.1 International Electrical Symbols
This symbol signifies that the instrument is protected by double or rein-
forced insulation.
This symbol on the instrument indicates a WARNING and that the operator
must refer to the user manual for instructions before operating the
instrument. In this manual, the symbol preceding instructions indicates that
if the instructions are not followed, bodily injury, installation/sample and
product damage may result.
Risk of electric shock. The voltage at the parts marked with this symbol may
be dangerous.
In conformity with WEEE 2002/96/EC

4
Megohmmeter Model 1015
1.2 Definition of Measurement Categories
CAT II: For measurements performed on circuits directly connected to
the electrical distribution system. Examples are measurements
onhouseholdappliancesorportabletools.
CAT III: For measurements performed in the building installation at
the distribution level such as on hardwired equipment in xed
installationandcircuitbreakers.
CAT IV: For measurements performed at the primary electrical supply
(<1000V) such as on primary overcurrent protection devices,
ripplecontrolunits,ormeters.
1.3 Receiving Your Shipment
Uponreceivingyour shipment,makesure thatthe contentsareconsis-
tentwiththe packinglist.Notify yourdistributor ofanymissing items.If
theequipmentappearstobedamaged,leaclaimimmediatelywiththe
carrierandnotifyyourdistributoratonce,givingadetaileddescriptionof
anydamage.Savethedamagedpackingcontainertosubstantiateyour
claim.
1.4 Ordering Information
MegohmmeterModel1015..................................................Cat. #1403.01
Includes a carrying case, shockproof rubber housing, set of black and red leads, black test
probe, red alligator clip, spare fuse (inside megohmmeter), four 1.5V alkaline “AA” batteries
(not installed), and a user manual.
1.4.1 Accessories and Replacement Parts
Setofreplacementleads..................................................... Cat. #2119.01
CarryingCase...................................................................... Cat. #2119.02
Fuses,setof5,1.6A............................................................Cat. #2970.22
Order Accessories and Replacement Parts Directly Online
Check our Storefront at www.aemc.com for availability

Megohmmeter Model 1015
5
CHAPTER 2
PRODUCT FEATURES
2.1 Description
TheMegohmmeterModel1015isananaloginstrumentwithfoureasy-to-
read scales.
TheMΩscaleisaneasy-to-readlogscalegraduatedfrom0.1to1000MΩ
(yellowbackground)at500Vand1000V.TheΩscaleislinearwitharange
from0to10Ω(whitebackground).
Tousethe0to1000Ωscale,takethereadingonthe0to10Ωrangeand
multiplythereadingby100.TheACvoltagescaleislinearwitharange
of0to600VAC(whitebackground).Continuitytestsaredonewithatest
currentof200mA.
Thecoloredbatteryscalehasarangeofgreenforagoodbatteryanda
rangeofredorlowerforadefectivebattery.
A built-in battery tester is provided by simply pressing the yellow push
buttonwhentheselectorswitchisintheOFFposition.
Voltmeter(safetycheck)witharangeof0to600VACisstandardandworks
whentheselectorswitchisinthe500Vpositionorthe1000Vposition.
2.2 Features
• Measuresinsulationat1000V
• 0 to 1000Ωresistancerange
• Pushbuttonforbatterycheck
• Designedforharshenvironments:offshore,mining,heavy-duty
eld,industrial,commercialelectricalandmilitaryuse
• 0 to 10Ω+ and 0 to 10Ω-continuityranges
• Continuity200mAtestcurrent
• Smallandlightweight
• Large,direct-reading,coloredscale
• 600Vtestvoltagerange(safetycheck)
• Yellownon-slipshockproofcase

6
Megohmmeter Model 1015
2.3 Control Features
–
1 2
3
4
5
6
7
Figure 2
1. Line(–)terminal
2. Earth/Ground(+)terminal
3. Mechanicalzeroadjustmentscrews
4. 4-positionrotaryswitch
5. Protectiverubberhousing
6. Push-to-testbutton
7. Batterycheckandindicationdisplay

Megohmmeter Model 1015
7
CHAPTER 3
SPECIFICATIONS
3.1 Electrical Specifications
INSULATION TESTS
DC Test Voltage:500Vand1000V
Megohm Range: 0.1 to 1000MΩ
Short Circuit Current: ≤6mA
Accuracy: ±5%ofreading
Discharging Time (Auto): 1s/µF
CONTINUITY TESTS
Range: 0 to 10Ω- ;0to10Ω+
Short Circuit Current: ≥200mA
Open Circuit Voltage: 4.5to6.5V
Accuracy: ±3%fullscale
RESISTANCE TESTS
Range: 0 to 1000Ω
Short Circuit Current: ≥2mA
Open Circuit Voltage: 4.5to6.5V
Accuracy: ±3%fullscale
VOLTAGE TESTS (Safety Check)
Voltage Range: 0to600VAC
Frequency: 45to400Hz
Accuracy:3%offullscale
Input Impedance:300kΩ

8
Megohmmeter Model 1015
3.2 General Specifications
Power Supply: Four1.5VAAbatteries
Dielectric Test:6000V,50/60Hz,1minute
Meter Movement: Ruggedtautbandsuspension
Dimensions: 6.6x4.2x2.2"(167x106x55mm)
Weight:1.45lbs(650 g)
Operating Temperature Range:
14°to131°F(-10°to55°C),20-80%RH
Storage Range:-40°to158°F(-40°to70°C),10-90%RH
Terminals: “-”Line(black);“+”earth(red);accepts4mmbananaplugs
Reference Conditions: 63° to 73°F (17° to 23°C), 45-55% RH; Supply Voltage: 5.3 to 5.7V;
Voltage Frequency: 45 to 65Hz; Electric Field: <1V/M; Magnetic Field: <40A/M; Position:
Horizontal ± 5°.
3.3 Safety Specifications
IEC 1010-1: Safety requirements for electrical equipment for measure-
ment,controlandlaboratoryuse
VDE 0413-1:Insulationtesters
VDE 0413-4: Ohmmeters
VDE 0100:Specicationsforthecreationofhighcurrentinstallationsof
nominalvoltagelessthan1000V
IEC 801: Electromagnetic compatibility for measurement and control
equipmentinindustrialprocesses
Part2:Sectionsrelatingtoelectrostaticdischarges
Part3:Sectionsrelatingtoradiatedelectricelds
Part4:Sectionsrelatingtoelectrostaticdischarges
Part5:Sectionsrelatingtoelectricshocks
IEC 68.2.6: Vibrations
IEC 68.2.27:Shocks
IEC 68.2.29:Shakes
IEC 68.2.31:Bumps
IEC 68.2.32:Freefall
UL 94: Self-extinguishingcapability
Specications are subject to change at any time without notice
Indice
Altri manuali AEMC Strumento di misura

AEMC
AEMC PowerPad 8435 Manuale utente

AEMC
AEMC MN03 Manuale utente

AEMC
AEMC 565 Manuale utente

AEMC
AEMC MN375 Manuale utente

AEMC
AEMC PowerPad III Manuale utente

AEMC
AEMC 3711 Manuale utente

AEMC
AEMC 6250 Manuale utente

AEMC
AEMC JM861 Manuale utente

AEMC
AEMC 1000N Manuale utente

AEMC
AEMC 4000D-14 Manuale utente