ArcPad 48 Integral (RGBW)
2
Table of contents
1. Safet instructions ...................................................................................................................................................... 3
2. Fixture exterior view ................................................................................................................................................... 5
3. Installation .................................................................................................................................................................. 5
3.1 Mounting the fixture ............................................................................................................................................ 5
3.2 Connection to the mains ...................................................................................................................................... 6
3.3 Installation of the barn-doors ............................................................................................................................... 8
3.4 Setting and control ............................................................................................................................................... 9
3.5 DMX 512 connection .......................................................................................................................................... 10
3.6 Master/slave connection .................................................................................................................................... 10
3.7 Stand-alone operation ........................................................................................................................................ 10
4. ArcPad 48 Integral (RGBCW) - DMX protocol ........................................................................................................... 11
5. Control menu map .................................................................................................................................................... 12
6. Fixture menu ............................................................................................................................................................. 14
6.1 Fixture Address ................................................................................................................................................... 15
6.2 Fixture information ............................................................................................................................................. 16
6.3 Personalit .......................................................................................................................................................... 17
6.4 Manual mode ...................................................................................................................................................... 18
6. 5 Test sequences................................................................................................................................................... 18
6.6 Stand-alone setting ............................................................................................................................................. 18
6.7 Special functions ................................................................................................................................................. 19
7. RDM .......................................................................................................................................................................... 21
8. Error and information messages .............................................................................................................................. 22
9. Technical specifications ............................................................................................................................................ 23
10. Cleaning and maintenance ..................................................................................................................................... 26

ArcPad 48 Integral (RGBW)
3
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE POWERING OR INSTALLING YOUR ArcPad 48 Inte ral !
Save it for future reference.
This device has left our premises in absolutel perfect condition. In order to maintain this condition and to ensure a
safe operation, it is absolutel necessar for the user to follow the safet instructions and warning notes written in
this manual.
The manufacturer will not accept liabilit for an resulting damages caused b the non-observance of this manual
or an unauthorized modification to the device.
Please consider that damages caused b manual modifications to the device are not subject to warrant .
1. Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT!
Make sure that the available voltage is not higher than stated on the rear panel of the fixture.
This fixture should be operated onl from the t pe of power source indicated on the marking label. If ou are not
sure of the t pe of power supplied, consult our authorized distributor or local power compan .
Alwa s disconnect the fixture from AC power before cleaning, removing or installing the fuses, or an part.
Do not overload wall outlets and extension cords as this can result in fire or electric shock.
Make sure that the power/data cord is never crimped or damaged b sharp edges. Check the fixture and the
power/data cord from time to time.
Do not install the unit near naked flames.
During the operation the housing becomes hot (up to 80°C)
Refer servicing to qualified service personnel.
This fixture falls under protection class I. Therefore this fixture has to be connected to a mains socket outlet with
a protective earthing connection.
Do not connect this fixture to a dimmer pack.
LED li ht emission. Risk of eye injury.
Do not look strai ht at the fixture´s LEDs durin operation. The intense li ht beam may dama e your eyes.
Keep compustible materials at least 20 cm awa from the fixture.
If the fixture has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on
immediatel . The arising condensation water might damage our device. Leave the device switched off until it has
reached room temperature.
Avoid brute force when installing or operating the fixture.
The fixture was designed for outdoor use. This fixture must not be used for underwater installation.

ArcPad 48 Integral (RGBW)
4
When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat or dust.
Avoid using the unit in locations subject to possible impacts.
The fixture bod never must be covered with cloth or other materials.
Onl operate the fixture after having checked that the housing is firml closed and all screws are tightl fastened.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the fixture.
Do not block the front objective LEDs with an object when the fixture is under operation.
The fixture becomes ver hot during operation. Allow the fixture to cool approximatel 30 minutes prior to
manipulate with it.
Operate the fixture onl after having familiarized with its functions. Do not permit operation b persons not
qualified for operating the fixture. Most damages are the result of unprofessional operation!
Do not attempt to dismantle or modif the unit.
Please consider that unauthorized modifications on the fixture are forbidden due to safet reasons!
Please use the original packaging if the fixture is to be transported.
If this device will be operated in an wa different to the one described in this manual, the product ma suffer
damages and the guarantee becomes void. Furthermore, an other operation ma lead to dangers like short-
circuit, burns, electric shock etc.

ArcPad 48 Integral (RGBW)
5
2. Fixture exterior view
3. Installation
3.1 Mounting the fixture
The ArcPad 48 Integral can be arranged in an position orientation.The ArcPpad 48 Integral´s radiator with LEDs is
mounted on an adjustable bracket for “tilt” adjustment into man positions:
Two slots (8.5mm wide) in the fixture base serve for mounting on the non-flammable flat surface:
1. Lens arra
2. Radiator
3.Base
4
. Power/data cord

ArcPad 48 Integral (RGBW)
6
Ensure that the structure to which you are attachin
the fixture is secure
Caution: Overhead installation requires experience. Fixtures ma cause severe injuries when crashing down! If ou
have doubts concerning the safet of a possible installation, do not install the device and consult installation with
an expert.
3.2 Connection to the mains
Fixtures must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and re ulation.
The ArcPad 48 Integral is equiped with with a 5-cored power/data cable. The 3 cores serve for the power suppl
and next 2 shielded cores are intended for DMX connection.
The power cores are coloured according to the following table.
Core
Connection
Plug Terminal Marking
Black
Live
L
B
lue
Neutral
N
Yellow/Green
Earth
This device falls under class one and must be grounded!
The data cores (DMX) are coloured according to the table:
Core
Connection
Brown
Data +
White
Data
-
Shielding
Data
ground
The power/data cable is connected to a junction box as shown on the picture below.

ArcPad 48 Integral (RGBW)
7

ArcPad 48 Integral (RGBW)
8
3.3 Installation of the barn doors
You can install the barn-doors to better define illuminated surface.
To install the barn-door module:
1. Disconnect the fixture from the mains.
2. Put the top edge of the barn-doors module into the second groove on the top side of the radiator ( detail
A) and the bottom edge into the second groove on the bottom side of the radiator and tighten four
locking screws M2 to secure this barn-doors module on the radiator.
ever close the barn-doors during fixture operation

ArcPad 48 Integral (RGBW)
9
3.4 Setting and control
For setting DMX address, selecting DMX mode and for another settings ou need either Robe Universal Interface
or the RDM Communicator. Please see the Robe Universal Interface or RDM Communicator user manuals to get
more information about this products. The wa , how to connect these interfaces to the DMX data link is figured
below.
OTE: never connect the RDM communicator and the The Robe Universal Interface to the fixture at the same
time.
1.Robe Universal Interface
2. RDM Communicator
Note: DMX controller has to be disconnected from the fixture when the RDM communicator is operated.

ArcPad 48 Integral (RGBW)
10
3.5 DMX 512 connection
To build a DMX chain
1. Connect the DMX output of the controller directl with the DMX input of the first fixture in the DMX chain.
2. Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture.
3. Alwa s connect the DMX output with the input of the next fixture until all fixtures are connected.
Do not overload the link. Max. 32 fixtures ma be connected on a DMX link.
Caution: Terminate the output of the last fixture with a 120 Ohm resistor wired betwen data (+) and data (-) in
order to ensure the proper transmission on the data link.
3.6 Master/slave connection
To build a master/slave-chain:
Connect the DMX output of the master fixture in the data chain with the DMX input of the first slave. Alwa s
connect output with the input of the next slave until all slaves are connected (up to 32 fixtures).
Caution: It is necessar to terminate the input of the master fixture and the output of the last slave with a 120 Ohm
resistor in order to ensure the proper transmission on the data link.
3.7 Stand alone operation
The fixtures on a data link are not connected to the controller but can execute pre-set programs which can be
different for ever fixture. To set the program to be pla ed, see the "Stand-alone setting" (menu "St.AL.").
"Stand-alone operation" can be applied to the single fixture or to multiple fixtures operating s nchronousl .
S nchronous operation of multiple fixtures requires that the must be connected on a data link and one of them is
set as a master (master mode) and the rest as the slaves (slave mode).
To set the fixture as the master or slave, see the " Fixture Address " (menu "A001").
Onl one fixture can be set as the master.
The master fixture starts simultaneous program start in the other slave fixtures. All fixtures have a definite,
s nchronized starting point when pla ing back their programs. The number of running program is the same in all
slaves and depends on the master's choice (menu "St.AL.“). Ever fixture runs its program repeatedl , starting the
program step No.1 when requested b the master.
Example:
If the slave fixture has a shorter program length, it will continuousl repeat its program until the master fixture
finishes its own program and restarts its program running (slave 1- prog.step 3 will not be finished).
If the slave fixture has a longer program length, it will restart at prog. step 1 before it completes all its prog.steps
(slave 2 - prog.step 5 will not be pla ed)- see the picture bellow.
ote: Disconnect the fixtures from the DMX controller before master/slave operating, otherwise data collisions
can occur and the fixtures will not work properl !
Altri manuali per ArcPad 48 Integral
1
Indice
Altri manuali Anolis Attrezzatura di illuminazione

Anolis
Anolis ArcPower 48 Outdoor /W Manuale utente

Anolis
Anolis ArcPad 48 Integral/W Manuale utente

Anolis
Anolis ArcSource 1 MC Short Manuale utente

Anolis
Anolis Robin MiniMe Manuale utente

Anolis
Anolis ArcPower 36 Manuale utente

Anolis
Anolis ArcSource Outdoor 48 MC Manuale utente

Anolis
Anolis ArcPar 100 Manuale utente

Anolis
Anolis ArcPower 144 Manuale utente

Anolis
Anolis ArcPad 48 Integral Manuale utente

Anolis
Anolis ArcWash Recessed 136 RGB Manuale utente