Anolis ArcPar 100 Manuale utente

1
Version 1.4 US

2
Table of contents
1. Safety instructions ......................................................................................................... 3
2. Fixture exterior view ...................................................................................................... 5
3. Installation....................................................................................................................... 6
3.1 Connection to the mains ............................................................................................ 6
3.2 Installing the diffusion lter......................................................................................... 7
3.3 Installing barndoors and the gel frame....................................................................... 8
3.4 Rigging the xture .................................................................................................... 10
3.5 DMX-512 connection................................................................................................ 12
3.6. Wireless DMX operation ......................................................................................... 13
3.7. Stand-alone and Master/Slave operation................................................................ 14
4. Control menu map........................................................................................................ 15
5. Robin ArcPar 100 - DMX chart..................................................................................... 17
5.1 Virtual colour wheel - colour mixing chart ................................................................ 20
5.2 LED zone order ........................................................................................................ 24
6. Control menu (Standard and Easy control mode)..................................................... 25
6.1 Addressing and master/slave setting (DMXA) ......................................................... 25
6.2 Fixture information (Info) .......................................................................................... 26
6.3 Personality (Pers)..................................................................................................... 26
6.4 Manual Control (Manual).......................................................................................... 27
6.5 Test program (Test Prg)........................................................................................... 27
6.6 Stand-alone (St Alone)............................................................................................. 27
6.7 Special functions (Special)....................................................................................... 28
7. RDM ............................................................................................................................... 29
8. Error and information messages ................................................................................ 30
9. Technical Specications.............................................................................................. 30
10. Maintenance and cleaning......................................................................................... 33
11. ChangeLog ................................................................................................................. 34
12. Photometric diagrams................................................................................................ 34
ArcPar 100

3
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE POWERING OR INSTALLING YOUR ArcPar 100 !
Save it for future reference.
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this manual.
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this
manual or any unauthorized modication to the device.
Please consider that damages caused by manual modications to the device are not subject to warranty.
The ArcPar 100 was designed for indoor use and it is intended for
professional application only. It is not for household use.
1. Safety instructions
DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS
UNIT!
Make sure that the available voltage is not higher than stated on the rear panel of the xture.
This xture should be operated only from the type of power source indicated on the marking label. If you are
not sure of the type of power supplied, consult your authorized distributor or local power company.
Always disconnect the xture from AC power before cleaning, removing or installing the fuses, or any part.
The power plug has to be accessible after installing the xture. Do not overload wall outlets and extension cords
as this canresult in re or electric shock.
Do not allow anything to rest on the power cord. Do not locate this xture where the cord may be damaged by
persons walking on it.
Make sure that the power cord is never crimped or damaged by sharp edges. Check the xture and the power
cord from time to time.
Refer servicing to qualied service personnel.
This xture falls under protection class I. Therefore this xture has to be connected to
a mains socket outlet with a protective earthing connection.
Do not connect this xture to a dimmer pack.
LED light emission. Risk of eye injury. Do not look into the beam at a distance of less
than 2 meters from the front surface of the product. Do not view the light output with
optical instruments or any device that may conncentrate the beam
If the xture has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your device. Leave the device switched off until
it has reached room temperature.
Do not shake the xture. Avoid brute force when installing or operating the xture.
This xture was designed for indoor use only, do not expose this unit to rain or use near water.
When choosing the installation spot, please make sure that the xture is not exposed to extreme heat, moisture

4
or dust.
Air vents and slots in the xture´s head and base are provided for ventilation, to ensure reliable operation of
the device and to protect it from overheating.
Do not block the LEDs array with any object when the xture is under operation.
The openings should never be covered with cloth or other materials, and never must be blocked.
This xture should not be placed in a built-in installation unless proper ventilation is provided.
Only operate the xture after having checked that the housing is rmly closed and all screws are tightly faste-
ned.
Always use a secondary safety cable when mounting this xture.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the xtu-
re.
Do not block the front objective LEDs with any object when the xture is under operation.
The xture becomes very hot during operation. Allow the xture to cool approximately 20 minutes prior to
manipulate with it.
Operate the xture only after having familiarized with its functions. Do not permit operation by persons not
qualied for operating the xture. Most damages are the result of unprofessional operation!
Please use the original packaging if the xture is to be transported.
Please consider that unauthorized modications on the xture are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, crash etc.

5
2. Fixture exterior view
4- DMX OUT
5- DMX IN
6 - Fuse holder
7 - Mains IN
8 - Mains OUT
9 - Display and control buttonsns
10 - Safety wire attachment pointt
1 - Mounting holder
2 - Tilt locks
3 - Lens array

6
3. Installation
Fixtures must be installed by a Qualied electrician in accordance with all
national and local electrical and construction codes and regulation.
3.1 Connection to the mains
For protection from electric shock, the xture must be earthed!
The ArcPar 100 is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz AC
power source from 100-240 Volts.
Install a suitable plug on the power cord, note that the cores in the power cord are coloured according to the
following table. The earth has to be connected!
If you have any doubts about proper installation, consult a qualied electrician.
Core (EU) Core (US) Connection Plug Terminal Marking
Brown Black Live L
Light blue White Neutral N
Yellow/Green Green Earth
This device falls under class one and must be earthed (grounded)!
Design of the ArcPar 100 allows to connect several xtures to AC mains power in one interconnected daisy
chain using power input and throughput connectors. Needed daisy chain cords are stated in the chapter
“Technical specications “
The max. number of connected xtures depends on the AC mains power voltage:
12 xtures at power supply= 230V
10 xtures at power supply= 208V
6 xtures at power supply= 120V
Do not overload the supply line and the connecting leads.
Wiring and connection work must be carried out by qualied staff!

7
3.2 Installing the diffusion lter
Disconnect the xture from mains before diffusion lter installation
1. Disconnect the xture from mains.
2. Insert the screw (1) with the plastic washer (2) into diffuser (3) and secure it by means of the
plastic washer (4.)
2. Insert the diffuser (3) into the ArcPar 100 and secure it by screwing the screw (1) into the thread hole (5)
in the plastic eggcrate. Keep the correct orientation of the diffuser sections (6).

8
3.3 Installing barndoors and the gel frame
Disconnect the xture from mains before barndoors and the gel frame installation
1.Disconnect the xture from mains.
2. Screw the accessory frame adaptor (1) on the ArcPar 100 housing with the four screws M4x8 (2) and unlock
the spring lock (3) via pushing this spring lock as show red arrows on the picture.
3. Insert the gel frame (4) into the bottom slots of the accessory frame adaptor (1).
4. Insert the barndoors (5) into the top slots of the accessory frame adaptor (1).

9
5. Secure both accessories by moving the spring lock (3) up as shows the red arrow on the picture.
Note: the barndoors can be rotated to desired position and secured in this position via the securing screw
(6).

10
3.4 Rigging the xture
A structure intended for installation of the xture (s) must safely hold weight of the xture(s) placed on it. The
structure has to be certicated to the purpose.
The xture (xtures) must be installed in accordance with national and local electrical and construction codes
and regulation.
For overhead installation, the xture must be always secured with a safety wire
When rigging, derigging or servicing the xture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert
before taking into operation for the rst time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled
person once a year.
Allow the xture to cool for ten minutes before handling.
The projector should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including calculating working
load limits, installation material being used, and periodic safety inspection of all installation material and the
projector. If you lack these qualications, do not attempt the installation yourself, but use a help of professional
companies.
CAUTION: Fixtures may cause severe injuries when crashing down! If you have doubts concerning the safety
of a possible installation, do not install the xture!
The xture has to be installed out of the reach of public.
The xture must never be xed swinging freely in the room.
When installing the device, make sure there is no highly inammable
material (decoration articles, etc.) in a distance of min. 0.4 m.
CAUTION!
Use an appropriate clamp to rig the xture on the truss.
Make sure that the device is xed properly! Ensure that the
structure (truss) to which you are attaching the xtures is secure.
For overhead installation, install a safety wire that can hold at least 10 times the weight of the xture. Use only
safety wire with screw-on carabine. Fasten the safety cable in the attachment point and around the truss
as shown on the picture below.
.
Indice
Altri manuali Anolis Attrezzatura di illuminazione

Anolis
Anolis ArcPad 48 Integral/W Manuale utente

Anolis
Anolis ArcSource Submersible II Manuale utente

Anolis
Anolis ArcPad 48 Integral Manuale utente

Anolis
Anolis ArcPar S1 Manuale utente

Anolis
Anolis Robin MiniMe Manuale utente

Anolis
Anolis ArcPower 48 Outdoor /W Manuale utente

Anolis
Anolis ArcPower 144 Manuale utente

Anolis
Anolis ArcWash Recessed 136 RGB Manuale utente

Anolis
Anolis ArcSource Outdoor 24 MC Integral SmartWhite Manuale utente

Anolis
Anolis ArcPad 48 Integral Manuale utente