Anolis ArcPower 36 Manuale utente

version 3.1

2
3
Table of contents
1. Safety instructions ......................................................................................................... 3
2. Operating determinations.............................................................................................. 3
3.Description of the ArcPower 36 ..................................................................................... 4
4.Installation........................................................................................................................ 4
4.1.Connection to the mains ............................................................................................ 4
4.2.Mounting the ArcPower 36......................................................................................... 5
4.3.Conection cables........................................................................................................ 5
5.Installing instructions. .................................................................................................... 6
5.1.DMX operating ........................................................................................................... 6
5.2.Master-slave operating............................................................................................... 8
6.ArcPower 36 - Control menu map.................................................................................. 9
7.ArcPower 36-DMX protocol ......................................................................................... 10
8.Control board................................................................................................................. 11
8.1 Addressing the ArcPower 36 ................................................................................... 11
8.2 Program running ...................................................................................................... 11
8.3 Manual mode ........................................................................................................... 12
8.4 Test sequences........................................................................................................ 13
8.5 Stand-alone mode.................................................................................................... 13
8.6 Special functions ...................................................................................................... 13
9.Control of the ArcPower 36 via RS-232....................................................................... 15
9.1Wiring an RS-232 serial port .................................................................................... 15
9.2 Selecting a zone....................................................................................................... 15
9.3 Setting a serial port of PC ........................................................................................ 15
9.4 Zone commands ...................................................................................................... 15
10.Technical Specications: ........................................................................................... 17
11 Replacing the fuse ..................................................................................................... 18
ArcPower 36

2
3
CAUTION!
Unplug mains lead before opening the housing!
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY
BEFORE YOU INITIAL START - UP!
1. Safety instructions
Every person involved with installation and maintenance of this product has to:
- be qualiled
- follow the instructions of this manual
CAUTION!
Be careful with your operations. With a high voltage you can suffer
a dangerous electric shock when touching the wires inside the unit!
This product has left our premises in absolutely perfect condition. In order to maintain this condition and to
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning
notes written in this manual.
To prevent from danger of accident ,the device has to be xed on at, non-f lam-
mable surface in compliance with the installing instruction included in this manual.
Important:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of this
manual or any unauthorized modication to the product.
Always ground the unit.
The electric connection, repairs and servicing must be carried out by a qualied employee.
Do not connect this unit to a dimmer pack.
Use a source of AC power that complies with local building and electrical rules.AC power has to have both
overload and short circuit protection
2. Operating determinations
This product was designed for indoor use only.
If the unit has been exposed to drastic temperature uctuation (e.g. after transportation), do not switch it on
immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has
reached room temperature.
Avoid brute force when installing or operating the unit.
When choosing the installation-spot, please make sure that the unit is not exposed to extreme heat, moisture
or dust.
Only operate the unit after having checked that the housing is rmly closed and all screws are tightly fas-
tened.
The maximum ambient temperature 40° C must never be exceeded.
Operate the unit only after having familiarized with its functions. Do not permit operation by persons not quali-
ed for operating the unit. Most damages are the result of unprofessional operation!
Please use the original packaging if the product is to be transported.
Please consider that unauthorized modications on the unit are forbidden due to safety reasons!

4
5
3.Description of the ArcPower 36
DMX Input,Output LED module Input
RJ45 socket RJ45 socket
Front view of the socket: Front view of the socket:
RS232 Input
Canon 9-pin male
Front view of the socket:
4.Installation
4.1.Connection to the mains
CE version:
This version of ArcPower 36 is equipped with auto-switching power supply that automatically adjusts to any
50/60Hz AC power source from 100-240 Volts.
1 - Control Board
2 - Power Indicator
3 - DMX Output
4 - DMX Input
5 - LED Module Input
6 - RS 232 Input
7 - Fuse Holder
8 - Power Cord
Pin 1: Not connected Pin 5: +5V
Pin 2: Not connected Pin 6: Data +
Pin 3: Not connected Pin 7: Data -
Pin 4: Not connected Pin 8: GND
Pin 1: Red LED + Pin 5: Red LED -
Pin 2: Green LED + Pin 6: Green LED -
Pin 3: Blue LED + Pin 7: Blue LED -
Pin 4: White LED + Pin 8: White LED -
Pin 1: Not connected
Pin 2: Received Data
Pin 3: Transmitted Data
Pin 4:
Pin 5: Signal Ground
Pin 6:
Pin 7:
Pin 8:
Pin 9: Not connected

4
5
Carefully prepare the end of the the supply cord and t a suitable plug.A 3-prong grounding-type plug must be
installed following the manufacturer´s instructions.The earth has to be connected!
Cord plug connections:
Cable Pin International
Brown Live L
Light blue Neutral N
Yellow/Green Earth
ETL version:
This version of ArcPower 36 is equipped with auto-switching power supply that automatically adjusts to any
50/60Hz AC power source from 100-120 Volts.
Connect the ArcPower 36 directly to AC power with the supply cord.
This device falls under protection class I.Therefore the ArcPower 36 has to be con-
nected to a mains socket outlet with a protective earthing connection.
4.2.Mounting the ArcPower 36
The ArcPower 36 should be be placed on a non-f lammable f lat surface in any orientation and xed by the two
screws.There are two mounting holes of diameter 5 mm in housing of the driver. Ensure that instalation place
is enough ventilated.
4.3.Conection cables
1.The adapter cable RJ45/XLR connects the ArcPower 36 to the DMX controller.If your DMX controller has
RJ45 socket for DMX output,use RJ45 patch cable for connection with the ArcPower 36.
RJ45 plug DMX 512 XLR plug (male)
View facing pins Front view of the plug
Pin 1: Not used Pin 1: GND
Pin 2: Not used Pin 2: Data -
Pin 3: Not used Pin 3: Data +
Pin 4: Not used Pin 4: Not used
Pin 5: +5V Pin 5: Not used
Pin 6: Data +
Pin 7: Data -
Pin 8: GND
Flat surface Mounting hole
Screw
Screw

6
7
2.RJ45 patch cables category 5 that connect the ArcPower 36 each other are wired 1:1,that is,pins with the
same numbers are connected together.
Pin 1: Not used Pin 1: Not used
Pin 2: Not used Pin 2: Not used
Pin 3: Not used Pin 3: Not used
Pin 4: Not used Pin 4: Not used
Pin 5: +5V Pin 5: +5V
Pin 6: Data + Pin 6: Data +
Pin 7: Data - Pin 7: Data -
Pin 8: GND Pin 8: GND
5.Installing instructions.
5.1.DMX operating
1.Unplug from the mains before installation.
2.Connect the LED modules to the xture.
3.Connect DMX controller to the xture
4.Connect the xture to the mains
5.Set the DMX address on the control board of the xture (see chapter "Control board").
Warning!
Accidental connection DMX 512 Input/Output to non-DMX 512 device (e.g.Ethernet
network Hub) can damage the ArcPower 36.
Maximum total cable length between Arcpower 36 and all connected LED modules
is 80 metres.
Single ArcPower 36 installation:
Multiple ArcPower 36 installation:
Connect the DMX output of the rst ArcPower 36 with the DMX input of the next ArcPower 36. Always connect
one output with the input of the next ArcPower 36 until all xtures are connected.In this way,up to 32 xtures
can be chained together.
At the last ArcPower 36 the data link has to be terminated with a terminator. A termination plug is simply a
RJ45 connector with a 120 Ω resistor between pins Data (–) and Data (+).Plug terminator in the DMX output
of the last ArcPower 36.
Maximum number of LEDs connected to the one ArcPower 36 is 42 (but maximum12 LEDs per colour).

6
7
Maximum possible number of LED modules connected to the one ArcPower 36:
Model
total
LEDs
Red
LEDs
Green
LEDs
Blue
LEDs
White
LEDs
Max.number
of connected
modules
ArcLine 12 RGB 12 4 4 4 - 3
ArcLine 24 RGB 24 8 8 8 - 1
ArcLine 36 RGB 36 12 12 12 - 1
ArcLine Optic 12 RGB 12 4 4 4 - 3
ArcLine Optic 24 RGB 24 8 8 8 - 1
ArcLine Optic 36 RGB 36 12 12 12 - 1
ArcSource 3 RGB 3 1 1 1 - 12
ArcSource 6 RGB 6 2 2 2 - 6
ArcSource 12 RGB 12 4 4 4 - 3
ArcSource 7 RGBW 7 2 2 2 1 6
Note: You cannot combine RGB and RGBW modules (e.g. ArcSource 6 RGB and ArcSource 7 RGBW)
each other as white LEDs will not light.

8
9
5.2.Master-slave operating
1.Unplug from the mains before installation.
2.Connect the LED module to the xtures.
3.Connect the DMX output of the master xture in the data-chain with the DMX input of the rst slave. Always
connect output with the input of the next slave until all slaves are connected.Up to 32 xtures can be connected
in master/slave chain
4.Insert the termination plug (with 120 Ohm) into DMX input of the master xture and into the DMX output of
the last slave xture in the link in order to ensure proper transmission on the data link.
5.Connect the xtures to the mains.
6.See chapter "Stand-alone mode" in order to set the xture as a master or slave.

8
9
6.ArcPower 36 - Control menu map
Default settings=Bold print
001 (001-506)
PrG
E.P.1
E.P.2
E.P.3
P.01
:
P.10
Aut (OFF,On)
EdI.
E.P.1
E.P.2
E.P.3 S.01
:
S.50
End
rEd (0-255)
:
:
FA.t.(0-255)
S.tI. (0-255)
COP.
MAn.
rEd (0-255)
GrE. (0-255)
bLu. (0-255)
Whi. (0-255)
MAC. (0-255)
Str. (0-255)
diM. (0-255)
tSt
St.A.
MSt.
E.P.1
:
P10
SLA.
SPE.
VEr.
bAL.(On,OFF)
C.bA.
rE.b. (0-200)
Gr.b. (0-255)
bL.b. (0-215)
Zon (Z.00-Z.09)
d.MP.
Mo.1
Mo.2
Mo.3
Mo.4
Mo.5
i.bL (On,OFF)
UPd.(No,YES)

10
11
7.ArcPower 36-DMX protocol ,version 1.4
Mode/Channel Value Function Type
of control
1 2 3 4 5
1 1 1 1 1 0-255
RED LED
Red LED saturation control (0-100%) proportional
2 2 2 2 2 0-255
GREEN LED
Green LED saturation control (0-100%) proportional
3 3 3 3 3 0-255
BLUE LED
Blue LED saturation control (0-100%) proportional
4 4 0-255
WHITE LED
White LED saturation control (0-100%) proportional
4 5
0-7
8-15
16-23
24-31
32-39
40-47
48-55
56-63
64-71
72-79
80-87
88-95
96-103
104-111
112-119
120-127
128-135
136-143
142-151
152-159
160-167
168-175
176-183
184-191
192-199
200-207
208-215
216-223
224-231
232-239
240-247
248-255
MACRO SELECTION
No function
Macro 1
Macro 2
Macro 3
Macro 4
Macro 5
Macro 6
Macro 7
Macro 8
Macro 9
Macro 10
Macro 11
Macro 12
Macro 13
Macro 14
Macro 15
Macro 16
Macro 17
Macro 18
Macro 19
Macro 20
Macro 21
Macro 22
Macro 23
Macro 24
Macro 25
Macro 26
Macro 27
Macro 28
Macro 29
Macro 30
Macro 31-rainbow effect from slow to fast
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
step
5 6
0-31
32-63
64-95
96-127
128-143
144-159
160-191
192-223
224-255
SHUTTER/STROBE
Shutter closed
Shutter open
Strobe-effect from slow to fast
Shutter open
Opening pulses in sequences slow--> fast
Closing pulses in sequences fast --> slow
Shutter open
Random strobe-effects from slow to fast
Shutter open
step
step
proportional
step
proportional
proportional
step
proportional
step
6 7 4 0-255
DIMMER
Dimmer intensity from 0% to 100% proportional
Indice
Altri manuali Anolis Attrezzatura di illuminazione

Anolis
Anolis Robin MiniMe Manuale utente

Anolis
Anolis ArcPower 144 Manuale utente

Anolis
Anolis ArcSource 1 MC Short Manuale utente

Anolis
Anolis ArcPad 48 Integral Manuale utente

Anolis
Anolis ArcSource Outdoor 24 MC Integral SmartWhite Manuale utente

Anolis
Anolis ArcPar S1 Manuale utente

Anolis
Anolis ArcPad 48 Integral/W Manuale utente

Anolis
Anolis ArcSource Submersible II Manuale utente

Anolis
Anolis ArcSource Outdoor 48 MC Manuale utente

Anolis
Anolis ArcWash Recessed 136 RGB Manuale utente