It is possible to change the key function by
setting the parameter
____0
The available options are:
-
ALL
(default): units of measure that can be selected: mm,
inch, D
-
nodEG
: units of measure that can be selected: mm, inch
-
OFF
: the key is disabled and does not allow changing
the selected measuring mode.
To program the parameters listed above, see paragraph 8.2.
7.3 Setting the absolute reference
After having selected the absolute measuring mode and
stopped the shaft in the starting position
or in the reference position, press the key
combination to set the absolute value to the sum of the
values of the parameters
OrG
(absolute value of reference)
and
OFFS
(compensation value).
The value of compensation (offset) allows you to adjust the
value shown on the display in such a way that takes into
account, for example, wear or tool change. The system
allows you to store up to 10 values of compensation. Press
the key combination +. The screen will display
the last compensation value used (eg
OFS 0
). Choose the
desired compensation value by pressing the key , and
then press the key to conrm.
The screen will display the absolute value to the sum of the
values of the parameters
ORG
and
OFFS
.
To program the offset values, see parameter
OFFS
of
paragraph 8.2.
It is possible to change the function of the keys combination
____0
+
7