EXFO FTB-5700 Manuale utente

User Guide
Single-Ended Dispersion Analyzer
for FTB-400
FTB-5700

ii FTB-5700
Copyright © 2007–2008 EXFO Electro-Optical Engineering Inc. All rights
reserved. No part of this publication may be reproduced, stored in a
retrieval system or transmitted in any form, be it electronically,
mechanically, or by any other means such as photocopying, recording or
otherwise, without the prior written permission of EXFO Electro-Optical
Engineering Inc. (EXFO).
Information provided by EXFO is believed to be accurate and reliable.
However, no responsibility is assumed by EXFO for its use nor for any
infringements of patents or other rights of third parties that may result from
its use. No license is granted by implication or otherwise under any patent
rights of EXFO.
EXFO’s Commerce And Government Entities (CAGE) code under the North
Atlantic Treaty Organization (NATO) is 0L8C3.
The information contained in this publication is subject to change without
notice.
Trademarks
EXFO’s trademarks have been identified as such. However, the presence
or absence of such identification does not affect the legal status of any
trademark.
Units of Measurement
Units of measurement in this publication conform to SI standards and
practices.
EXFO’s Universal Interface is protected by US patent 6,612,750.
Protected by international PCT patent application (published under
WO2007/036051) and several other pending applications.
Version number: 2.0.1

Contents
Single-Ended Dispersion Analyzer iii
Contents
Certification Information ........................................................................................................v
1 Introducing the FTB-5700 Single-Ended Dispersion Analyzer ................... 1
Module Description ................................................................................................................2
Typical Applications ................................................................................................................2
Basic FTB-5700 Single-Ended Dispersion Analyzer Operation ..................................................3
Conventions ............................................................................................................................5
2 Safety Information ....................................................................................... 7
3 Getting Started with the Single-Ended Dispersion Analyzer .................... 9
Inserting and Removing Test Modules ....................................................................................9
Starting the Single-Ended Dispersion Analyzer Application ..................................................14
Exiting the Application .........................................................................................................16
4 Setting Up the Single-Ended Dispersion Analyzer ................................... 17
Setting up Application Details ..............................................................................................17
Customizing Thresholds ........................................................................................................23
Setting the Wavelength Range .............................................................................................25
Setting PMD and CD Acquisition Parameters ........................................................................27
Defining the Automatic Fiber Name Format .........................................................................31
Managing Test Configurations ..............................................................................................32
Setting Test Preferences ........................................................................................................38
5 Operating the Single-Ended Dispersion Analyzer .................................... 41
Cleaning and Connecting Optical Fibers ...............................................................................41
Installing the EXFO Universal Interface (EUI) .........................................................................42
Performing a Test ..................................................................................................................43
6 Managing Results ....................................................................................... 47
Modifying Analysis Parameters and Related Information ......................................................50
Opening Existing Files ...........................................................................................................58
Removing Unwanted Results ................................................................................................59
Closing Result Files ...............................................................................................................60
Generating a Report .............................................................................................................61
7 Maintenance ............................................................................................... 63
Cleaning EUI Connectors ......................................................................................................64
Recalibrating the Unit ...........................................................................................................66
Recycling and Disposal (Applies to European Union Only) ....................................................67

Contents
iv FTB-5700
8 Troubleshooting ..........................................................................................69
Solving Common Problems ...................................................................................................69
Obtaining Online Help ..........................................................................................................76
Contacting the Technical Support Group ..............................................................................77
Transportation ......................................................................................................................78
9 Warranty ......................................................................................................79
General Information .............................................................................................................79
Liability .................................................................................................................................80
Exclusions .............................................................................................................................80
Certification ..........................................................................................................................80
Service and Repairs ...............................................................................................................81
EXFO Service Centers Worldwide ..........................................................................................82
A Technical Specifications ..............................................................................83
Index .................................................................................................................85

Certification Information
Single-Ended Dispersion Analyzer v
Certification Information
F.C.C. Information
Electronic test equipment is exempt from Part 15 compliance (FCC) in
the United States. However, compliance verification tests are
systematically performed on most EXFO equipment.
Information
Electronic test equipment is subject to the EMC Directive in the European
Union. The EN61326 standard prescribes both emission and immunity
requirements for laboratory, measurement, and control equipment.
This unit has undergone extensive testing according to the European Union
Directive and Standards.

Certification Information
vi FTB-5700
Application of Council Directive(s): 73/23/EEC - The Low Voltage Directive
89/336/EEC - The EMC Directive
Manufacturer’s Name: EXFO ELECTRO-OPTICAL ENG.
Manufacturer’s Address: 400 Godin Avenue, Quebec (Quebec)
Canada G1M 2K2
(418) 683-0211
Equipment Type/Environment: Industrial Scientific Equipment
Trade Name/Model No.: FTB-5700 Single-Ended Dispersion Analyzer
Standard(s) to which Conformity is Declared:
EN 61010-1:2001 Safety Requirements for Electrical Equipment for Measurement,
Control, and Laboratory Use, Part 1: General Requirements.
EN 55022: 1998/ A2: 2003 Limits and Methods of Measurement of Radio Disturbance
Characteristics of Information Technology Equipment.
EN 61326:1997 / A1:1998 +
A2:2001 + A3:2003
Electrical Equipment for Measurement, Control and Laboratory
Use - EMC Requirements
EN 60825-1:1994 / A2: 2001 Safety of laser products – Part 1: Equipment classifications,
requirements, and user’s guide
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive and Standards.
Manufacturer
Signature:
Full Name: Stephen Bull, E. Eng
Position: Vice-President Research and
Development
Address: 400 Godin Avenue, Quebec (Quebec)
Canada
Date: November 21, 2007
DECLARATION OF CONFORMITY

Single-Ended Dispersion Analyzer 1
1 Introducing the FTB-5700
Single-Ended Dispersion
Analyzer
The FTB-5700 Single-Ended Dispersion Analyzer is the world’s first
combined CD and PMD analyzer doing both measurements from a single
end of the fiber. It features a single connector port and software for both
type of measurements; CD and PMD are characterized by pressing a single
button. This is done without the need for a remote unit or light source.
As long as the remote end of the fiber is unterminated and with a UPC
connector, a single technician can perform advanced testing, that is, CD
and PMD measurements. The results are also compiled into a single test
file and a single report for both tests.

Introducing the FTB-5700 Single-Ended Dispersion Analyzer
2FTB-5700
Module Description
Module Description
The figure below illustrates the front panel for your Single-Ended
Dispersion Analyzer
Typical Applications
With its dynamic range, level of accuracy and feature set, the FTB-5700
Single-Ended Dispersion Analyzer is a perfect tool for any network
manager or technician to perform advance testing of 10 Gbit/s networks or
faster, on any fiber length up to 120 km. The FTB-5700 Single-Ended
Dispersion Analyzer helps validating fiber quality for the given speed or
providing information enabling compensation.
Port
Handle
SINGLE-ENDED DISPERSION ANALYZER
FTB-5700

Introducing the FTB-5700 Single-Ended Dispersion Analyzer
Single-Ended Dispersion Analyzer 3
Basic FTB-5700 Single-Ended Dispersion Analyzer Operation
Basic FTB-5700 Single-Ended Dispersion
Analyzer Operation
The purpose of the FTB-5700 Single-Ended Dispersion Analyzer unit is to be
simple of use, with minimal parameter setting requirements. The
parameter most likely to be changed by a user is the fiber type.
In order to achieve optimal measurements, you must however remember
a few concepts:
³The measurement technique for the unit requires only a strong
reflective event at the end of the link to perform CD and PMD
measurements. The measurement is taken at the location of this
reflective event at a wavelength of 1550 nm.
Note: Reflective events are caused by an abrupt discontinuity in the index of
refraction. They cause a significant portion of the energy initially launched
into the fiber to be reflected back toward the source.
³You must have a UPC connector at the end of the fiber to measure the
overall link. If the appropriate termination is not found, the unit returns
an error message (see Troubleshooting on page 69 for details).
Note: Other reflective terminations include mirror connectors, fiber pigtailed
mirrors, cleaved fibers. However, do not use fiber loop mirrors or
Faraday-type mir rors.

Introducing the FTB-5700 Single-Ended Dispersion Analyzer
4FTB-5700
Basic FTB-5700 Single-Ended Dispersion Analyzer Operation
Once the fiber end event position is found, the unit checks the dynamics
and evaluates the wavelength range over which to perform the
measurement. It then selects the acquisition conditions and sequence of
the measurement before starting the acquisition itself.
You must also remember that the fiber under test (FUT) must meet the
following requirements for optimal testing conditions:
³The FUT length must be terminated by a UPC connector.
³The FUT length must be less than 120 km.
³The FUT must not have a filter at 1550 nm.
Note: Since the instrument is single ended, it cannot measure through
components that allow light to travel only in one direction, such as
amplifiers and circulators.
Indice
Altri manuali EXFO Strumento di misura

EXFO
EXFO FTB-5230S Manuale utente

EXFO
EXFO ETS-1000L Manuale utente

EXFO
EXFO T100S-HP Series Manuale utente

EXFO
EXFO FTB-740 DWOCC Series Manuale utente

EXFO
EXFO FPM-600 Manuale utente

EXFO
EXFO IQ-5500 Manuale utente

EXFO
EXFO USER GUIDE Manuale utente

EXFO
EXFO VFL Manuale utente

EXFO
EXFO PMD Analyzer 5500B Manuale utente

EXFO
EXFO IQ Series Manuale utente

EXFO
EXFO IQS-5320-EI Manuale utente

EXFO
EXFO IQS-12008 Manuale utente

EXFO
EXFO IQ-5320 Manuale utente

EXFO
EXFO FTB-5240S Manuale utente

EXFO
EXFO T200S Manuale utente

EXFO
EXFO OmniCure R2000 Manuale utente

EXFO
EXFO EPM-50 Manuale utente

EXFO
EXFO FTB-5800 Manuale utente

EXFO
EXFO FTB-2 Manuale operativo e di manutenzione

EXFO
EXFO LTB-12 Manuale utente