MR MSENSE DGA 2 Manuale utente

Online Oil Analysis
MSENSE® DGA 2/3
Operating Instructions
BA4001150/10 EN

© All rights reserved by Messko GmbH
Dissemination and reproduction of this document and use and disclosure of its content are strictly prohibited
unless expressly permitted.
Infringements will result in liability for compensation. All rights reserved in the event of the granting of patents,
utility models or designs.
The product may have been altered since this document was published.
We reserve the right to change the technical data, design and scope of supply.
Generally the information provided and agreements made when processing the individual quotations and orders
are binding.
The original operating instructions were written in German.

Table of contents
Messko GmbH 2020 3BA4001150/10 EN MSENSE® DGA 2/3
Table of contents
1 Introduction......................................................................................................................... 6
1.1 Manufacturer....................................................................................................................................... 6
1.2 Subject to change without notice ........................................................................................................ 6
1.3 Completeness..................................................................................................................................... 6
1.4 Safekeeping........................................................................................................................................ 6
1.5 Notation conventions .......................................................................................................................... 7
1.5.1 Hazard communication system .............................................................................................................................7
1.5.2 Information system................................................................................................................................................8
1.5.3 Instruction system .................................................................................................................................................8
1.5.4 Typographic conventions ......................................................................................................................................9
2 Safety................................................................................................................................. 10
2.1 Appropriate use ................................................................................................................................ 10
2.2 Fundamental safety instructions ....................................................................................................... 11
2.3 Personnel qualification...................................................................................................................... 12
2.4 Personal protective equipment ......................................................................................................... 13
3 IT security.......................................................................................................................... 15
4 Product description.......................................................................................................... 16
4.1 Scope of delivery .............................................................................................................................. 17
4.2 Function description.......................................................................................................................... 18
4.3 Design............................................................................................................................................... 19
4.4 Safety markings and nameplate ....................................................................................................... 20
5 Packaging, transport and storage .................................................................................. 21
5.1 Purpose ............................................................................................................................................ 21
5.2 Suitability, structure and production.................................................................................................. 21
5.3 Markings ........................................................................................................................................... 21
5.4 Transportation, receipt and handling of shipments........................................................................... 21
5.5 Storage of shipments........................................................................................................................ 23
5.6 Further transport ............................................................................................................................... 23
6 Installation......................................................................................................................... 24
6.1 Installation recommendation............................................................................................................. 24

Table of contents
Messko GmbH 20204BA4001150/10 ENMSENSE® DGA 2/3
6.2 Mounting the device.......................................................................................................................... 25
6.2.1 Preparing the transformer and ball valve ............................................................................................................25
6.2.2 Mounting the MSENSE® DGA 2/3......................................................................................................................30
6.3 Electrical connection......................................................................................................................... 39
6.3.1 Electromagnetic compatibility..............................................................................................................................40
6.3.2 Cable recommendation .......................................................................................................................................40
6.3.3 Routing and preparing the cables .......................................................................................................................40
6.3.4 Supply voltage and protective conductor ............................................................................................................41
6.3.5 Device grounding ................................................................................................................................................42
6.3.6 Analog outputs ....................................................................................................................................................42
6.3.7 Main switching contacts ......................................................................................................................................44
6.3.8 SCADA connection .............................................................................................................................................45
6.4 Ensuring offshore capability.............................................................................................................. 48
7 Commissioning................................................................................................................. 51
7.1 Service interface ............................................................................................................................... 51
7.2 Installing the MESSKO® MSET parameterization software ............................................................. 52
7.3 Commissioning in existing systems .................................................................................................. 53
7.4 Parameterization............................................................................................................................... 53
7.4.1 Settings for carbon monoxide (DGA 3 only), hydrogen and H2O concentrations in the oil ................................54
7.4.2 General settings ..................................................................................................................................................55
7.4.3 Modbus settings ..................................................................................................................................................56
8 Operation........................................................................................................................... 58
8.1 Operating the device with display ..................................................................................................... 59
8.1.1 General operation ...............................................................................................................................................60
8.1.2 Main screen / Operating display..........................................................................................................................61
8.1.3 Events .................................................................................................................................................................63
8.2 Operating the device without display ................................................................................................ 64
9 Fault elimination ............................................................................................................... 65
9.1 Messages regarding the safety switching contact ............................................................................ 65
9.2 Other faults ....................................................................................................................................... 66
9.3 Replace safety fuse .......................................................................................................................... 66
10 Maintenance...................................................................................................................... 68
10.1 Inspection ......................................................................................................................................... 68
10.2 Maintenance ..................................................................................................................................... 69

Table of contents
Messko GmbH 2020 5BA4001150/10 EN MSENSE® DGA 2/3
10.3 Oil extraction..................................................................................................................................... 70
10.4 Device field calibration...................................................................................................................... 71
10.4.1 Taking a sample for field calibration....................................................................................................................71
10.4.2 Field calibration ...................................................................................................................................................73
10.4.3 Reading out the service database.......................................................................................................................78
10.5 Cleaning............................................................................................................................................ 79
11 Removal............................................................................................................................. 80
11.1 Removing the MSENSE® DGA 2/3.................................................................................................. 80
12 Disposal............................................................................................................................. 89
13 Technical data................................................................................................................... 90
14 Appendix ........................................................................................................................... 93
14.1 Device dimensions with 285 mm measuring pipe length.................................................................. 93
14.2 Device dimensions with 507 mm measuring pipe length.................................................................. 94
14.3 Connecting flange dimensions.......................................................................................................... 95
14.4 Electrical connection......................................................................................................................... 97
14.5 Data point table for Modbus RTU ..................................................................................................... 98
14.6 Spare parts list................................................................................................................................ 100

1 Introduction
Messko GmbH 20206BA4001150/10 ENMSENSE® DGA 2/3
1 Introduction
This technical document contains detailed descriptions on the safe and
proper installation, connection, commissioning and monitoring of the prod-
uct.
This technical document is intended solely for specially trained and autho-
rized personnel.
1.1 Manufacturer
The product is manufactured by:
Messko GmbH
Gewerbegebiet An den Drei Hasen
Messko-Platz 1
61440 Oberursel
Germany
Phone: +49 6171 6398-0
E-mail: [email protected]
Internet: www.reinhausen.com/messko
Further information on the product and copies of this technical document are
available from this address if required.
1.2 Subject to change without notice
The information contained in this technical file comprises the technical speci-
fications approved at the time of printing. Significant modifications will be in-
cluded in a new edition of the technical file.
The document number and version number of this technical file are shown in
the footer.
1.3 Completeness
This technical document is incomplete without the supporting documents.
The following documents apply to this product:
▪ MSENSE®DGA 2/3 operating instructions
▪ MESSKO®MSET parameterization software operating instructions
▪ Works certification
1.4 Safekeeping
Keep this technical file and all supporting documents ready at hand and ac-
cessible for future use at all times.

1 Introduction
Messko GmbH 2020 7BA4001150/10 EN MSENSE® DGA 2/3
1.5 Notation conventions
This section contains an overview of the symbols and textual emphasis
used.
1.5.1 Hazard communication system
Warnings in this technical file are displayed as follows.
1.5.1.1 Warning relating to section
Warnings relating to sections refer to entire chapters or sections, sub-sec-
tions or several paragraphs within this technical document. Warnings relat-
ing to sections have the following format:
WARNING Type of danger!
Source of the danger and its consequences.
► Action
► Action
1.5.1.2 Embedded warning information
Embedded warnings refer to a particular part within a section. These warn-
ings apply to smaller units of information than the warnings relating to sec-
tions. Embedded warnings use the following format:
DANGER! Instruction for avoiding a dangerous situation.
1.5.1.3 Signal words and pictograms
The following signal words are used:
Signal word Definition
DANGER Indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
WARNING Indicates a hazardous situation which, if not avoided, could result
in death or serious injury.
CAUTION Indicates a hazardous situation which, if not avoided, could result
in minor or moderate injury.
NOTICE Indicates measures to be taken to prevent damage to property.
Table1: Signal words in warning notices

1 Introduction
Messko GmbH 20208BA4001150/10 ENMSENSE® DGA 2/3
Pictograms warn of dangers:
Pictogram Definition
Warning of a danger point
Warning of dangerous electrical voltage
Warning of combustible substances
Warning of a tipping hazard
Warning of a hot surface
Table2: Pictograms used in warning notices
1.5.2 Information system
Information is designed to simplify and improve understanding of particular
procedures. In this technical file it is laid out as follows:
Important information.
1.5.3 Instruction system
This technical file contains single-step and multi-step instructions.
Single-step instructions
Instructions which consist of only a single process step are structured as fol-
lows:

1 Introduction
Messko GmbH 2020 9BA4001150/10 EN MSENSE® DGA 2/3
Aim of action
üRequirements (optional).
► Step 1 of 1.
ðResult of step (optional).
ðResult of action (optional).
Multi-step instructions
Instructions which consist of several process steps are structured as follows:
Aim of action
üRequirements (optional).
1. Step 1.
ðResult of step (optional).
2. Step 2.
ðResult of step (optional).
ðResult of action (optional).
1.5.4 Typographic conventions
The following typographic conventions are used in this technical file:
Typographic convention Purpose Example
UPPERCASE Operating controls, switches ON/OFF
[Brackets] PC keyboard [Ctrl] + [Alt]
Bold Software operating controls Press Continue button
…>…>… Menu paths Parameter > Control parameter
Italics System messages, error messages,
signals
Function monitoring alarm triggered
[► Number of pages]. Cross reference [► 41].
Table3: Typographic conventions

2 Safety
Messko GmbH 202010 BA4001150/10 ENMSENSE® DGA 2/3
2 Safety
This technical document contains detailed descriptions on the safe and
proper installation, connection, commissioning and monitoring of the prod-
uct.
▪ Read this technical file through carefully to familiarize yourself with the
product.
▪ This technical file is a part of the product.
▪ Read and observe the safety instructions provided in this chapter in partic-
ular.
▪ Observe the warnings in this technical file in order to avoid function-re-
lated dangers.
▪ The product is manufactured on the basis of state-of-the-art technology.
Nevertheless, risks to life and limb for the user or impairment of the prod-
uct and other material assets may arise in the event of improper use.
2.1 Appropriate use
The device is designed solely for use in electrical energy systems and facili-
ties. It is designed to detect and report emerging, potentially harmful trends
in the monitored equipment (e.g. transformer) in good time by measuring the
concentration of gases and moisture in the equipment's insulating oil.
The device is not designed and is not suitable for detecting rapidly develop-
ing faults and therefore is not intended to protect the equipment from such
faults (e.g. through shutdown). For this, please use safety devices that have
been designed for this purpose.
If used as intended and in compliance with the requirements and conditions
specified in this technical document as well as the warning notices contained
in this technical document and attached to the product, the product does not
pose risk of personal injury or damage to property or the environment. This
applies throughout the entire service life of the product, from delivery, instal-
lation and operation to removal and disposal.
Intended use refers to the following:
▪ Operate the product in accordance with this technical document, the
agreed-upon delivery conditions and the technical data.
▪ Ensure that any necessary work is only performed by qualified personnel.
▪ Only use the equipment included in the delivery for the intended purpose
and in accordance with the specifications of this technical document.
▪ Observe the notices in this technical document regarding electromagnetic
compatibility and the technical data.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali MR Strumento di misura

MR
MR MESSKO EI100 Manuale utente

MR
MR MESSKO EI100 Manuale utente

MR
MR MSENSE BM Manuale utente

MR
MR MESSKO MFLOC 2.0 Manuale utente

MR
MR TAPCON LV Manuale utente

MR
MR MESSKO BeTech Manuale utente

MR
MR MESSKO PQ96 Manuale utente

MR
MR MSENSE BM Manuale utente

MR
MR MESSKO MFLOC 2.0 Manuale utente

MR
MR TAPGUARD 260 Manuale utente