5. Restore to Factory Setting
R718MA saves data including network key information, configuration information, etc. To restore to
factory setting, users need to execute below operations.
1. Press and hold function key for 5 seconds till the green indicator flashes and then release; LED
flashes quickly 20 times.
2. R718MA is at off mode by default setting after restoring to factory setting.
Note: The device operation of turning off is the same as the “Restore Factory Settings”operation.
6. Sleeping Mode
R718MA is designed to enter sleeping mode for power-saving in some situations:
(A) While the device is in the network →the sleeping period is Min Interval. (During this
period, if the reportchange is larger than setting value, it will wake up and send a data report).
(B) When it is not in the network →R718MA will enter sleeping mode and wake up every
15 seconds to search a network to join in the first two minutes. After two minutes, it will wake
up every 15 minutes to request to join the network.
If it’s at (B) status, to prevent this unwanted power consumption, we recommend that users
remove the batteries to power off the device.
7. Low Voltage Alarming
The operating voltage threshold is 3.2V. If the battery voltage is lower than 3.2V, R718MA will
send a low-power warning to the LoRa network.
8. Installation
This product comes with waterproof function. When using it, the back of it can be adsorbed on the
iron surface, or the two ends can be fixed to the wall with screws.
Note: To install the battery, use a screwdriver or similar tool to assist in opening the battery cover.