Control module
IHB GB 1624-6
231758

Quick guide
Navigation
Ok button (confirm/select)
Back button (back/undo/exit)
Control knob (move/increase/reduce)
A detailed explanation of the button functions can be found on page 31.
How to scroll through menus and make different settings is described on page 33.
temperature1.1
Set the indoor climate
2X
INDOOR CLIMATE
HOT WATER
INFO
HEAT PUMP
The mode for setting the indoor temperature is accessed by pressing the OK button twice, when in the start mode
in the main menu.
INDOOR CLIMATE
HOT WATER
INFO
HEAT PUMP
off
temporary lux2.1
3 hrs
6 hrs
12 hrs
one time
increase
Increase hot water volume
2X
1X
To temporarily increase the amount of hot water (if a hot water heater is installed to your SMO 20), first turn the
control knob to mark menu 2 (water droplet) and then press the OK button twice.
In event of disturbances in comfort
If a disturbance in comfort of any type occurs there are some measures that can be taken before you need to
contact your installer. See page 46 for instructions.

Table of Contents
41 Important information
4Safety information
4General
72 Delivery and handling
7Mounting
7Supplied components
83 The Control Module Design
8Electrical components
94 Pipe connections
9General
9Compatible NIBE air/water heat pumps
9Symbol key
10Temperature sensor installation on pipe
10Docking alternatives
145 Electrical connections
14General
15Accessibility, electrical connection
16Cable lock
17Connections
20Optional connections
24Connecting accessories
256 Commissioning and adjusting
25Preparations
25
Commissioning with NIBE air/water heat
pump
25Commissioning with additional heating only
25Check the reversing valve
25Check AUX socket
25Cooling mode
26Start guide
27Setting the cooling/heating curve
29Setting hot water circulation
30SG Ready
317 Control - Introduction
31Display unit
32Menu system
358 Control
35Menu 1 - INDOOR CLIMATE
36Menu 2 - HOT WATER
36Menu 3 - INFO
37Menu 4 - MY SYSTEM
38Menu 5 - SERVICE
439 Service
43Service actions
4610 Disturbances in comfort
46Manage alarm
46Troubleshooting
47Additional heating only
4811 Accessories
5012 Technical data
50Dimensions and setting-out coordinates
51Technical specifications
52Energy labelling
53Electrical circuit diagram
57Index
3Table of Contents |SMO 20

Safety information
This manual describes installation and service procedures
for implementation by specialists.
This appliance can be used by children
aged from 8 years and above and per-
sons with reduced physical, sensory or
mental capabilities or lack of experience
and knowledge if they have been given
supervision or instruction concerning use
of the appliance in a safe way and under-
stand the hazards involved. Children shall
not play with the appliance. Cleaning
and user maintenance shall not be made
by children without supervision.
Rights to make any design or technical
modifications are reserved.
©NIBE 2016.
Symbols
NOTE
This symbol indicates danger to machine or
person.
Caution
This symbol indicates important information
about what you should observe when maintain-
ing your installation.
TIP
This symbol indicates tips on how to facilitate
using the product.
Marking
SMO 20 is CE marked and fulfils IP21.
The CE marking means that NIBE ensures that the
product meets all regulations that are placed on it based
on relevant EU directives. The CE mark is obligatory for
most products sold in the EU, regardless where they are
made.
IP21 means that objects with a diameter larger than or
equivalent to 12.5 mm cannot penetrate and cause
damage and that the product is protected against vertic-
ally falling drops of water.
General
Serial number
The serial number can be found on the top of the cover
for the control module and in the info menu (menu 3.1).
LEK
Serial number
Caution
Always give the product's serial number when
reporting a fault.
Recovery
Leave the disposal of the packaging to the in-
staller who installed the product or to special
waste stations.
Do not dispose of used products with normal
household waste. It must be disposed of at a
special waste station or dealer who provides this type of
service.
Improper disposal of the product by the user results in
administrative penalties in accordance with current legis-
lation.
Country specific information
Installer manual
This installer manual must be left with the customer.
SMO 20Chapter 1 | Important information4
1 Important information

Inspection of the installation
Current regulations require the heating installation to be inspected before it is commissioned. The inspection must
be carried out by a suitably qualified person. Fill in the page for information about installation data in the User
manual.
DateSignatureNotesDescription
✔
Electricity (page 14)
Communication, heat pump
Connected supply 230 V
Outside sensor
Temperature sensor, hot water charging
Temperature sensor, hot water top
Temperature sensor, external flow line
Temperature sensor, external supply line
after electric heater
Temperature sensor, external return line
Charge pump
Shuttle valve
AUX1
AUX2
AUX3
AUX4
AUX5
AUX6
AA2-X4
Miscellaneous
Checking additional heater
Checking the function of the reversing
valve
Checking charge pump function
Completed installation check of heat
pump and associated equipment
5Chapter 1 | Important informationSMO 20
......................................................................................................................................................................................................................................................................................................................................................................................................................................................................

Contact information
KNV Energietechnik GmbH, Gahberggasse 11, 4861 Schörfling
Tel: +43 (0)7662 8963-0 Fax: +43 (0)7662 8963-44 E-mail: mail@knv.at www.knv.at
AT
NIBE Wärmetechnik c/o ait Schweiz AG, Industriepark, CH-6246 Altishofen
CH
Druzstevni zavody Drazice s.r.o, Drazice 69, CZ - 294 71 Benatky nad Jizerou
CZ
NIBE Systemtechnik GmbH, Am Reiherpfahl 3, 29223 Celle
DE
Vølund Varmeteknik A/S, Member of the Nibe Group, Brogårdsvej 7, 6920 Videbæk
DK
NIBE Energy Systems OY, Juurakkotie 3, 01510 Vantaa
FI
NIBE Energy Systems France Sarl, Zone industrielle RD 28, Rue du Pou du Ciel, 01600 Reyrieux
FR
NIBE Energy Systems Ltd, 3C Broom Business Park, Bridge Way, Chesterfield S41 9QG
GB
NIBE Energietechniek B.V., Postbus 634, NL 4900 AP Oosterhout
NL
ABK AS, Brobekkveien 80, 0582 Oslo, Postadresse: Postboks 64 Vollebekk, 0516 Oslo
NO
NIBE-BIAWAR Sp. z o. o. Aleja Jana Pawła II 57, 15-703 BIAŁYSTOK
Tel: 085 662 84 90 Fax: 085 662 84 14 E-mail: sekretariat@biawar.com.pl www.biawar.com.pl
PL
© "EVAN" 17, per. Boynovskiy, Nizhny Novgorod
RU
NIBE AB Sweden, Box 14, Hannabadsvägen 5, SE-285 21 Markaryd
SE
For countries not mention in this list, please contact Nibe Sweden or check www.nibe.eu for more information.
SMO 20Chapter 1 | Important information6

Mounting
NOTE
For wall mounting, use the mounting adapted
for the base.
110
410
360
110
10
310
215
70
35
Use all mounting points and install SMO 20 upright flat
against the wall without any part of the control module
protruding out beyond the edge of the wall.
Leave at least 100 mm free space around the control
module to facilitate access and cable routing on installa-
tion and service.
NOTE
Access the screws for installing the front cover
from underneath.
Supplied components
Heating pipe pasteOutside sensor
LEK
Temperature sensorInsulation tape
LEK
Cable tiesAluminium tape
7Chapter 2 | Delivery and handlingSMO 20
2 Delivery and handling

LEK
L N 1 1 0 2 3 4PE
21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
AA2
AA4-XJ3
X1
SF1
AA4
X2
AA7
AA4-XJ4
LEK
L N 1 1 0 2 3 4PE
AA2
X1
FA1
AA7
UB2UB1
PF3
Electrical components
Base cardAA2
Display unitAA4
AA4-XJ3 USB socket
AA4-XJ4 Service outlet (No function)
Extra relay circuit boardAA7
Miniature circuit-breakerFA1
Terminal block, incoming electrical supplyX1
Terminal block, control signal circulation pump,
sensors AUX inputs and heat pump
X2
SwitchSF1
Serial number platePF3
Cable grommet, incoming supply electricity,
power for accessories
UB1
Cable gland, signalUB2
Designations in component locations according to
standard IEC 81346-1 and 81346-2.
SMO 20Chapter 3 | The Control Module Design8
3 The Control Module Design

General
Pipe installation must be carried out in accordance with
current norms and directives. See manual for compatible
NIBE air/water heat pump for installation of the heat
pump.
Compatible NIBE air/water heat
pumps
Compatible NIBE air/water heat pumps must be
equipped with a control card that has at least the soft-
ware version given in the following list. The control card
version is displayed in the heat pump's display (if applic-
able) upon start-up.
Software versionProduct
55F2015
55F2016
118F2020
55F2025
55F2026
all versionsF2030
all versionsF2040
all versionsF2120
55F2300
Symbol key
MeaningSymbol
Shut-off valve
Tapping valve
Trim valve
Shunt / reversing valve
Safety valve
Temperature sensor
Expansion vessel
Pressure gauge
P
Circulation pump
Particle filter
Auxiliary relay
Compressor
Heat exchanger
Radiator system
Domestic hot water
Under floor heating systems
Cooling system
9Chapter 4 | Pipe connectionsSMO 20
4 Pipe connections

Temperature sensor installation
on pipe
LEK
LEK
The temperature sensors are mounted with heat con-
ducting paste, cable ties (the first cable tie is secured to
the pipe in the middle of the sensor and the other cable
tie is mounted approx. 5 cm beyond the sensor) and
aluminium tape. Then insulate with supplied insulation
tape.
NOTE
Sensor and communication cables must not be
placed near power cables.
Docking alternatives
SMO 20 can be connected with other products from
NIBE in several different ways, some of which are shown
below (accessories may be required).
Further option information is available at www.nibe.eu
and in the respective assembly instructions for the ac-
cessories used. See page 48 for a list of the accessories
that can be used with SMO 20.
Installations with SMO 20 can produce heating and hot
water. Cooling can also be produced, depending on
which heat pump is used.
On cold days of the year when the access to energy from
the air is reduced the additional heating can compensate
and help to produce heat. The additional heating is also
good to have as assistance if the heat pump ends up
outside its working range or if it has been blocked for
any reason.
NOTE
The heating medium side and the hot water
side must be fitted with the necessary safety
equipment in accordance with the applicable
regulations.
This is the outline diagram. Actual installations
must be planned according to applicable
standards.
SMO 20Chapter 4 | Pipe connections10
Altri manuali per SMO 20
9
Indice
Altri manuali Nibe Unità di controllo
Manuali Unità di controllo popolari di altre marche

Festo
Festo Compact Performance CP-FB6-E Manuale elenco delle parti

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manuale utente

JS Automation
JS Automation MPC3034A Manuale utente

JAUDT
JAUDT SW GII 6406 Series Guida rapida

Spektrum
Spektrum Air Module System Manuale utente

BOC Edwards
BOC Edwards Q Series Manuale utente