Scale Computing HC3 Manuale utente

HC3 Hardware and System
Installation Guide
© Scale Computing 2019 Version 3.0: 02/2019 | 1

Table of Contents
Important Safety and Usage Information 3
Online Installation Reference 4
Networking Preparations 4
System Preparations and Configurations 4
Rack Installation 4
HC3 Shipping, Hardware, and Power 5
HC3 Family Shipping 5
HC1000 Family Hardware 5
Compute and Networking 5
Storage 6
Miscellaneous 6
HC5000 Family Hardware 7
Compute and Networking 7
Storage 7
Miscellaneous 7
HC1000 Family Environment and Power Specifications 8
HC5000 Family Environment and Power Specifications 9
HC3 Software Only Environment and Power Specifications 10
HC3 Installation Preparation 12
What to Expect After Your Purchase 12
Pre-Installation Checklist 12
Customer Portal Access 13
Partner and Distributor Portal Access 13
Login or Register for a Portal Account 14
Environment Questionnaire 15
Scheduling Your Professional Services 16
Node Configuration 18
Configure the Nodes 18
Common Configuration Troubleshooting 19
System Initialization 20
Initialize the System 20
What Next? 21
Videos 21
Technical Help 21
Feedback & Support 21
© Scale Computing 2019 Version 3.0: 02/2019 | 2

Important Safety and Usage Information
1. Please disconnect ALL power and network cords before servicing or moving the unit.
2. Please note all chassis manufacturers' safety instructions for proper node lifting and transport.
3. This product is intended for installation in a restricted access location or equivalent area. Please ensure
appropriate precautions are taken as confidential and/or sensitive data may be stored on this product after
installation.
4. This product’s BIOS configuration may use replaceable batteries as a backup power source in the event that
a power outage occurs. If you suspect the batteries have failed, DO NOT attempt to replace them yourself
due to risk of injury if an improper replacement is used. Contact your hardware support provider for proper
replacement steps.
5. Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Consideration should be given to
installing the equipment in an environment compatible with the maximum ambient temperature (Tma)
specified by the manufacturer.
6. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
7. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is
not achieved due to uneven mechanical loading.
8. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit
and the effect that overloading of the circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
9. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention
should be given to supply connections other than direct connections to the branch circuit (e.g. use of power
strips).
© Scale Computing 2019 Version 3.0: 02/2019 | 3

Online Installation Reference
Thank you for your recent Scale Computing HC3 System purchase! We are excited to have you as a customer and
look forward to making sure you are satisfied with every part of your experience with Scale Computing.
Scale Computing aims to provide you with an informative and productive introduction to your new HC3 System
solution. If you haven’t already, check out the convenient online installation references that pair with this HC3
Hardware and System Installation Guide.
Networking Preparations
Reference the Networking Guidelines and Recommendations guide for the most up-to-date information on
networking best practices and recommended configurations, as well as references for port requirements, physical
NIC layouts, and more.
System Preparations and Configurations
Reference the HyperCore Support Matrix for the latest on supported node configurations, system limitations and
best practices, virtual drivers, supported web browsers, and much more.
Rack Installation
Watch the 2 minute video for your purchased model for step-by-step assistance when racking the node. And yes,
it's really that easy!
If you're utilizing an HC3 Software Only node model - currently a Lenovo x3550 M5, Lenovo SR630, or Lenovo
SR650 platform - please see your hardware manufacturer's documentation and/or resources for information on
proper mounting, racking, and installation of your hardware lines.
© Scale Computing 2019 Version 3.0: 02/2019 | 4

HC3 Shipping, Hardware, and Power
It is important to understand the underlying hardware capabilities and power requirements of your specific node
lines. You'll find the base build options for each HC3 family line as well as their available upgrades in this chapter.
HC3 Family Shipping
HC1200
HC1250
HC1250D
HC1250DF
HC5250D
Shipping Dimensions
32" L x 23" W x 7" H
39" L x 24" W x 9" H
39" L x 24" W x 11" H
Shipping Weight
40 lbs
56 lbs
77 lbs
Carry Weight Out of Box
36 lbs
Minimum: 26.2 lbs (11.9 kg)
Maximum: 41.4 lbs (18.8 kg)
Minimum: 41.9 lbs (19 kg)
Maximum: 70.5 lbs (32 kg)
HC1000 Family Hardware
Compute and Networking
HC1200
Standard
HC1250
Standard
HC1200
Upgrade
Options
HC1250
Upgrade
Options
HC1250D(F)
Standard
HC1250D(F) Upgrade
Options
CPU
Intel Xeon
SP 3104
6 Cores - 6
Threads
1.7GHz
Intel Xeon
SP 4110
8 Cores - 16
Threads
2.1GHz
Intel Xeon
SP 4110
8 Cores - 16
Threads
2.1GHz
Intel Xeon
SP 4114
10 Cores - 20
Threads
2.2GHz
2 x Intel Xeon SP 4110
16 Cores - 32 Threads
2.1GHz
2 x Intel Xeon SP 4114
20 Cores - 40 Threads
2.2GHz
2 x Intel Xeon SP 6136
24 Cores - 48 Threads
3.0GHz
RAM
64GB DDR4
96GB DDR4
128GB DDR4
192GB DDR4
256GB DDR4
384GB DDR4
128GB DDR4
192GB DDR4
256GB DDR4
384GB DDR4
512GB DDR4
768GB DDR4
Networking
4 x 1GbE or 10GbE
10GBaseT (RJ-45)
Intel X550-T2
2 Public NICs Bonded
Active/Passive
2 Private NICs Bonded
Active/Passive
4 x 10GbE SFP+
Intel X710-DA4
2 Public NICs bonded
active/passive
2 Private NICs bonded
active/passive
4 x 1GbE or 10GbE
10GBaseT (RJ-45) Intel
X722
2 Public NICs Bonded
Active/Passive
2 Private NICs Bonded
Active/Passive
4 x 10GbE SFP+ Intel
X722
2 Public NICs bonded
active/passive
2 Private NICs bonded
active/passive
Power
Supply
2 x 500W
Redundant Power Supplies
2 x 750W
Redundant Power Supplies
© Scale Computing 2019 Version 3.0: 02/2019 | 5

Storage
Standard Storage
Storage Upgrade Options
HC1200
NL-SAS (7200 RPM)
4TB RAW Capacity / 2TB Usable Capacity (4x1TB)
NL-SAS (7200 RPM)
8TB RAW Capacity / 4TB Usable Capacity (4x2TB)
16TB RAW Capacity / 8TB Usable Capacity (4x4TB)
32TB RAW Capacity / 16TB Usable Capacity (4x8TB)
HC1250
NL-SAS (7200 RPM)
3TB RAW Capacity / 1.5TB Usable Capacity (3x1TB)
SSD
480GB RAW Capacity / 240GB Usable Capacity (1x480GB)
NL-SAS (7200 RPM)
6TB RAW Capacity / 3TB Usable Capacity (3x2TB)
12TB RAW Capacity / 6TB Usable Capacity (3x4TB)
24TB RAW Capacity / 12TB Usable Capacity (3x8TB)
SSD
960GB RAW Capacity / 480GB Usable Capacity (1x960GB)
1.92TB RAW Capacity / 960GB Usable Capacity (1x1.92TB)
3.84TB RAW Capacity / 1.92TB Usable Capacity (1x3.84TB)
7.68TB RAW Capacity / 3.84TB Usable Capacity (1x7.68TB)
HC1250D
NL-SAS (7200 RPM)
3TB RAW Capacity / 1.5TB Usable Capacity (3x1TB)
SSD
960GB RAW Capacity / 480GB Usable Capacity (1x960GB)
NL-SAS (7200 RPM)
6TB RAW Capacity / 3TB Usable Capacity (3x2TB)
12TB RAW Capacity / 6TB Usable Capacity (3x4TB)
24TB RAW Capacity / 12TB Usable Capacity (3x8TB)
SSD
1.92TB RAW Capacity / 960GB Usable Capacity (1x1.92TB)
3.84TB RAW Capacity / 1.92TB Usable Capacity (1x3.84TB)
7.68TB RAW Capacity / 3.84TB Usable Capacity (1x7.68TB)
HC1250DF
SSD
3.84TB RAW Capacity / 1.92TB Usable Capacity (4x960GB)
SSD
7.68TB RAW Capacity / 3.84TB Usable Capacity (4x1.92TB)
15.37TB RAW Capacity / 7.68TB Usable Capacity (4x3.84TB)
30.72TB RAW Capacity / 15.36TB Usable Capacity
(4x7.68TB)
Miscellaneous
Rack
Certifications
Miscellaneous
HC1200
1U Rack Height
1.7” (43mm) H x 17.2” (437mm) W x 25.6” (650mm) D
UL/CB, CE, FCC
Rack Rails, Power Cables, Bezel
Onboarding Reference Card
HC1250
1U Rack Height
1.7” (43mm) H x 17.2” (437mm) W x 25.6” (650mm) D
HC1250D
1U Rack Height
1.7” (43mm) H x 17.1” (434mm) W x 28.1” (715mm) D
HC1250DF
1U Rack Height
1.7” (43mm) H x 17.1” (434mm) W x 28.1” (715mm) D
© Scale Computing 2019 Version 3.0: 02/2019 | 6

HC5000 Family Hardware
Compute and Networking
HC5250D Standard
HC5250D Upgrade Options
CPU
2 x Intel Xeon SP 4110
16 Cores - 32 Threads
2.1GHz
2 x Intel Xeon SP 4114 2 x Intel Xeon SP 6136
20 Cores - 40 Threads 24 Cores - 48 Threads
2.2GHz 3.0GHz
RAM
128GB DDR4
192GB DDR4
256GB DDR4
384GB DDR4
512GB DDR4
768GB DDR4
1024GB DDR4
Networking
4 x 10GbE SFP+ Intel X722
2 Public NICs bonded active/passive
2 Private NICs bonded active/passive
Power
2 x 750W
Redundant Power Supplies
Storage
Base Storage
Storage Upgrade Options
HC5250D
NL-SAS (7200 RPM)
36TB RAW Capacity / 18TB Usable Capacity (9x4TB)
SSD
2.88TB RAW Capacity / 1.44TB Usable Capacity (3x960GB
NL-SAS (7200 RPM)
72TB RAW Capacity / 36TB Usable Capacity (9x8TB)
SSD
5.76TB RAW Capacity / 2.88TB Usable Capacity (3x1.92TB)
11.52TB RAW Capacity / 5.76TB Usable Capacity (3x3.84TB)
23.04TB RAW Capacity / 11.52TB Usable Capacity
(3x7.68TB)
Miscellaneous
Rack
Certifications
Miscellaneous
HC1250DF
2U Rack Height
3.4” (87mm) H x 17.5” (445mm) W x 28.3”
(720mm) D
UL/CB, CE, FCC
Rack Rails, Power Cables, Bezel
Onboarding Reference Card
© Scale Computing 2019 Version 3.0: 02/2019 | 7

HC1000 Family Environment and Power Specifications
HC1200/1250 Operating
Environment
Operating Air Temperature
5°C - 35°C (41°F - 95°F)
Non-Operating Air Temperature
-40°C - 70°C (-40°F - 158°F)
Operating Humidity
8% - 90% (non-condensing)
Non-Operating Humidity
5% - 95% (non-condensing)
HC1250D(F) Operating
Environment
Operating Air Temperature
10 °C - 35 °C (50 °F - 95 °F)
Altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1
°C for every 300-m (984-ft) increase in altitude.
Non-Operating Air Temperature
5 °C - 45 °C (41 °F - 113 °F)
Storage Air Temperature
-40 °C - +60 °C (-40 °F - 140 °F)
Operating Humidity
8% - 80% (non-condensing)
21 °C (70 °F) Max Dew Point
Storage Humidity
8% - 90% (non-condensing)
HC1200 Power
Idle
Load
Startup
Staging
Watts
138.4
204
147
37.1
Amps
1.2
1.804
1.199
0.307
kVA
0.1384
0.204
0.147
0.0371
BTU/hr
472.22
696.05
501.56
126.59
Test Voltage
121.1
120.6
120.9
121.2
HC1250 Power
Idle
Load
Startup
Staging
Watts
142.7
204
161.3
37.5
Amps
1.18
1.81
1.334
0.309
kVA
0.1427
0.204
0.1613
0.0375
BTU/hr
486.89
696.05
550.36
127.95
Test Voltage
121.1
120.6
120.9
121.2
© Scale Computing 2019 Version 3.0: 02/2019 | 8

HC1250D(F) Power 10GbE SFP+
Idle
Load
Startup
Staging
Watts
145
227
177
25.8
Amps
0.84
0.954
1.106
0.89
kVA
0.145
0.227
0.177
0.0258
BTU/hr
494.74
774.52
603.92
88.03
Test Voltage
122.2
122.2
122.2
122.2
HC1250D(F) Power 10GBaseT
Idle
Load
Startup
Staging
Watts
214
417
278
33.1
Amps
0.84
0.954
1.106
0.89
kVA
0.214
0.417
0.278
0.0331
BTU/hr
730.17
1422.80
948.54
112.94
Test Voltage
122.2
122.2
122.2
122.2
HC5000 Family Environment and Power Specifications
HC5250D Operating Environment
Operating Air Temperature
10 °C - 35 °C (50 °F - 95 °F)
Altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C
for every 300-m (984-ft) increase in altitude.
Non-Operating Air Temperature
5 °C - 45 °C (41 °F - 113 °F)
Storage Air Temperature
-40 °C - +60 °C (-40 °F - 140 °F)
Operating Humidity
8% - 80% (non-condensing)
21 °C (70 °F) Max Dew Point
Storage Humidity
8% - 90% (non-condensing)
HC5250D Power 10GbE SFP+ Only
Idle
Load
Startup
Staging
Watts
252
370
276
27.1
Amps
0.84
0.954
1.106
0.89
kVA
0.252
0.37
0.276
0.0271
BTU/hr
859.82
1262.44
941.71
92.47
Test Voltage
122.2
122.2
122.2
122.2
© Scale Computing 2019 Version 3.0: 02/2019 | 9

HC3 Software Only Environment and Power Specifications
Lenovo x3550 M5 Operating
Environment
Operating Air Temperature
5 °C - 40 °C (41 °F - 104 °F)
Altitudes above 950 m decrease the maximum system temperature by 1 °C for every
175-m increase.
Non-Operating Air Temperature
5 °C - 45 °C (41 °F - 113 °F)
Storage Air Temperature
-40 °C - +60 °C (-40 °F - 140 °F)
Operating Humidity
8% - 85% (non-condensing)
24 °C Max Dew Point
Storage Humidity
8% - 85% (non-condensing)
27 °C Max Dew Point
Lenovo SR630 Operating
Environment
Operating Air Temperature
10 °C - 35 °C (50 °F - 95 °F)
Altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1
°C for every 300-m (984-ft) increase in altitude.
Non-Operating Air Temperature
5 °C - 45 °C (41 °F - 113 °F)
Storage Air Temperature
-40 °C - +60 °C (-40 °F - 140 °F)
Operating Humidity
8% - 80% (non-condensing)
21 °C (70 °F) Max Dew Point
Storage Humidity
8% - 90% (non-condensing)
Lenovo SR650 Operating
Environment
Operating Air Temperature
10 °C - 35 °C (50 °F - 95 °F)
Altitudes above 900 m (2,953 ft), decrease the maximum ambient temperature by 1 °C
for every 300-m (984-ft) increase in altitude.
Non-Operating Air Temperature
5 °C - 45 °C (41 °F - 113 °F)
Storage Air Temperature
-40 °C - +60 °C (-40 °F - 140 °F)
Operating Humidity
8% - 80% (non-condensing)
21 °C (70 °F) Max Dew Point
Storage Humidity
8% - 90% (non-condensing)
© Scale Computing 2019 Version 3.0: 02/2019 | 10