CONNECTIONS
SAFETY EDGE AND FLASHING LAMP
11
10 11 12 13
1 2 3 4 5 6 7 8 9
CN1
EDG2 Safety edge
in opening
9
11
10
13
11
EDG1 Safety edge
in closing
CONNECTIONS COURTESY LIGHT
CN5
34 35
It blinks once per second during opening and twice per second during
closing, while it remains lit during pause.
Throught the warning light it is also possible to identify alarm signals
comming from the STOP, PHOTOCELL 1, PHOTOCELL2 and EDGE
devices. On board display it is possible to activate the pre -flashing function
and/or fixed flashing, defaults signals lamp or Buzzer.
The pre-flashing can be set from 0 to 5 s. or it is possible to have it only
before closing.
33
10 11 12 13
1 2 3 4 5 6 7 8 9
CN1
When pressing this button the motor immediately stops in any
condition/position.
To re-start the movement give a start command.
After a stop the motor always re-starts in closing.
• Function 1 (STANDARD): partial opening space adjustble from 20 to 100 (90-
PARTIAL OPENING menu).
• Function 2 (TIMER): by holding STDP 4 the gate opens and then stay opened.
While you release it the gate repeat the pause selected time and start closing.
In case a safety is activated the timer will automatically reset after 6 sec.
• Function 3 (2 BUTTONS): in 2 buttons logic press the STPD 4 to close the gate.
• Function 4 (DEADMAN): in deadman logic this button executes the re-closing if you
keep it pressed.
PARTIAL OPENING (N.O.) 4
STOP (N.C.) 5
3
6
5
6
STOP
PARTIAL
OPENING
6
4
C
• Function 1 (STANDARD): a
• Function 2 (TIMER): h
In case of activation of a safety device the timer will automatically reset after 6 seconds.
• Function 3 (2 BUTTONS):
• Function 4 (DEADMAN):
n impulse given to this
contact opens and closes the automation depending on the
Selected logic.
To connect the other devices refer to the related instructions leaflets (ie. loop detectors and proximity
Switches).
in deadman logic keep pressed the Start for the opening of the automation.
olding START starts the TIMER function, releasing the start, the operator repeats the pause
V and then close.
in 2 buttons logic this button performs the opening.
START (N.O.) 3
START
-
ANTENNA
Pressing EDG1 and EDG2, the contact opens, causing a partial reversing of the gate in closing and opening.
Note1: the EDG1 and EDG2 inputs can be set: only in closing, only in opening or in both directions.
Note2: It is possible to activate a balanced edge 8K2 through the on board display or through the Jolly programmer, in such
case the edge contact will be controled by a specific resistance value, detecting the possible involontary short circuit of the
device. In case of an imbalanced device a special alarm will show on the on board display or on the JOLLY programmer.
If you connect a wireless edge it is possible to make a self-test on the power
supply of the receiver by connecting it to 24Vac and selecting in the 96-EDGE
AUTOTEST menu the edge or the edges on which to perform the test.
SAFETY EDGE - EDGE 1 9 EDGE 2 10
24V FLASHING LIGHT 3W MAX 13
CONNECTIONS
PARTIAL OPENING, STOP, START
English
Timing from 0 to 4 min
(230V~ 50W Max -
115V~ 50W Max)