SICK MAX48 Manuale

TECHNICAL INFORMATION
MAX48
Non-contact position sensors

Product described
MAX48
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is only
permissible within the limits of the legal determination of Copyright Law. Any modifica‐
tion, abridgment or translation of this document is prohibited without the express writ‐
ten permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
2T E C H N I C A L I N F O R M A T I O N | MAX48 8021473/2017-08-08 | SICK
Subject to change without notice

Contents
1 About this document........................................................................ 5
1.1 Purpose of this document........................................................................ 5
1.2 Target audience........................................................................................ 5
1.3 Further information................................................................................... 5
1.4 Symbols and document conventions...................................................... 5
1.4.1 Warning levels and signal words............................................. 5
1.4.2 Information symbols................................................................ 5
2 Safety information............................................................................ 6
2.1 General notes............................................................................................ 6
2.2 Intended use............................................................................................. 6
2.2.1 Purpose of the device.............................................................. 6
2.3 Responsibility of user............................................................................... 6
3 Product description........................................................................... 8
3.1 Product identification............................................................................... 8
3.2 Device variants......................................................................................... 8
3.3 Construction and function........................................................................ 9
4 Mounting............................................................................................. 11
4.1 Preparation for installing the sensor....................................................... 11
4.1.1 Installation cavity for the sensor............................................. 11
4.1.2 Installation cavity for the piston rod....................................... 11
4.1.3 Insertion chamfer.................................................................... 12
4.1.4 Bore hole for the retaining screw............................................ 12
4.1.5 Bore hole for the connector system....................................... 13
4.1.6 Piston for the position magnet................................................ 14
4.2 Installing the position magnet................................................................. 15
4.3 Location of the O-ring and support ring.................................................. 16
4.4 Installing the sensor in the cylinder........................................................ 16
4.4.1 Installing using an M12 connector system............................ 16
4.4.2 Installation using cable connector and screwed cable
gland......................................................................................... 18
4.5 Install the retaining screw........................................................................ 18
4.6 Cylinder handling after sensor installation............................................. 18
4.6.1 Washing and drying the cylinder............................................. 18
4.6.2 Electrostatic painting of the cylinder...................................... 19
4.6.3 Mounting the cylinder on mobile hydraulic machines.......... 19
4.6.4 Electrical and electrostatic interference................................ 19
5 Electrical installation........................................................................ 21
5.1 Electrical connection................................................................................ 21
5.1.1 Connection diagrams, pin assignment.................................. 21
5.1.2 Connection sequence.............................................................. 21
CONTENTS
8021473/2017-08-08 | SICK T E C H N I C A L I N F O R M A T I O N | MAX48 3
Subject to change without notice

5.2 Connection diagram for vehicle electronics............................................ 22
6 Commissioning.................................................................................. 23
6.1 Commissioning the device....................................................................... 23
6.2 Select a suitable fuse............................................................................... 23
6.3 Set up the filter wiring.............................................................................. 23
6.4 Tolerance considerations for the set point............................................. 24
7 Transport and storage....................................................................... 26
7.1 Transport and storage conditions............................................................ 26
8 Maintenance...................................................................................... 27
8.1 Checking the device function................................................................... 27
8.2 Error table................................................................................................. 28
8.3 Repairs...................................................................................................... 28
9 Decommissioning............................................................................. 29
9.1 Dismantling............................................................................................... 29
9.2 Disposal..................................................................................................... 29
10 Technical data.................................................................................... 30
10.1 Analog MAX48.......................................................................................... 30
10.2 Dimensions of sensor............................................................................... 32
10.3 Dimensions of position magnet............................................................... 33
11 Annex.................................................................................................. 34
11.1 Accessories............................................................................................... 34
11.2 CE Declaration of Conformity................................................................... 34
CONTENTS
4T E C H N I C A L I N F O R M A T I O N | MAX48 8021473/2017-08-08 | SICK
Subject to change without notice

1 About this document
1.1 Purpose of this document
In this document, the MAX48 position sensor is referred to simply as “device”.
This Technical Information describes:
•Device components
•Mechanical preparation of the device
•Electrical preparation of the device
•Necessary maintenance work for safe operation
1.2 Target audience
This document is intended for technicians (persons with technical expertise) tasked
with installing and maintaining the device.
These technicians must be trained on the device.
Only trained electricians are permitted to carry out work on the electrical system or
electrical assemblies.
1.3 Further information
•MAX48 Operating Instructions
Product web page for the MAX48
www.sick.com/MAX48
1.4 Symbols and document conventions
1.4.1 Warning levels and signal words
Important
Hazard which could result in property damage.
Note
Tips
1.4.2 Information symbols
Table 1: Information symbols
Icon Meaning
Important technical information for this product
Important information about electrical or electronic functions
ABOUT THIS DOCUMENT 1
8021473/2017-08-08 | SICK T E C H N I C A L I N F O R M A T I O N | MAX48 5
Subject to change without notice

2 Safety information
2.1 General notes
Should persons be placed at risk, or operating equipment potentially be damaged in
the event of a malfunction or failure of the device, this must be prevented by means of
suitable protective devices, e. g., emergency shutdown systems.
If the device is not functioning correctly, it must be taken out of operation and secured
against unauthorized operation.
To guarantee proper operation of the device, please observe the following:
•Protect the device against mechanical stress during installation
•Do not open the device
•Connect the device with the correct polarity, supply voltage and control pulses
•Observe the permissible operating and ambient conditions for the device
•Regularly check the device for correct operation and document the results
2.2 Intended use
2.2.1 Purpose of the device
The MAX48 sensor is designed to take position measurements in mobile hydraulic
applications and therefore can be used to control the hydraulic components of con‐
struction machinery, e.g., in hydraulic cylinders. The rugged housing offers optimal pro‐
tection against dust, climatic influences, vibrations, surrounding media as well as
electrical and magnetic fields.
The device is an accessory and must be connected to a suitable electronic control unit.
2.3 Responsibility of user
Designated users
see "Target audience", page 5.
Correct project planning
•This document assumes that appropriate project planning has been carried out
before delivery of the device (e.g., based on the SICK application questionnaire),
and the device is in the required delivery state based on that planning (see sup‐
plied system documentation).
wIf you are not certain whether the device corresponds to the state defined
during project planning or in the supplied system documentation, please con‐
tact SICK Customer Service.
Special local conditions
In addition to the instructions in this Technical Information, follow all local laws, techni‐
cal rules and company-internal operating directives applicable at the respective device
installation location.
Read the technical information
•Read and follow the technical information in this document
•Follow all safety notes
•If there is anything you do not understand, please contact SICK Customer Service
2 SAFETY INFORMATION
6T E C H N I C A L I N F O R M A T I O N | MAX48 8021473/2017-08-08 | SICK
Subject to change without notice

Retention of documents
This Technical Information:
bMust be made available for reference.
bMust be conveyed to new owners.
SAFETY INFORMATION 2
8021473/2017-08-08 | SICK T E C H N I C A L I N F O R M A T I O N | MAX48 7
Subject to change without notice

3 Product description
3.1 Product identification
Type code
Table 2: Type code
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
M T X 4 8 N - 1 1 R 1 0 T T
Table 3: Type code Explanation
Position Meaning Value
1 Series M = Mobile
2 Technology A = Magnetostrictive
3 Installation type X = Integrated (hydraulic cylinder)
4 Size 48 = Housing diameter
5
6 Version N = Non-Safety
7 Place holder -
8 Diameter
Pressure pipe
1 = 10 mm / 30 mm damping
7 = 7 mm / 30 mm damping
9 Voltage supply 1 = 12 VDC
2 = 24 VDC
10 Electrical
Interface
V = Voltage
A = Current
11 Signal output 10 = Analog 4.00 ... 20.00 VDC
21 = Analog 4.75 ... 0.25 VDC
40 = Analog 1.00 ... 9.00 VDC
12
13 Connection type A = 4-pin analog (1 = VDC, 2 = n.c., 3 = GND, 4 = OUT)
B = 4-pin analog (1 = VDC, 2 = OUT, 3 = GND, 4 = n.c.)
M = 4-pin analog (1 = n.c., 2 = VDC, 3 = GND, 4 = OUT)
K = Analog cable/3-wire PWM
14 Connector length A = 60 mm M12
E = 100 mm M12
15 Measuring range
Position measurement
in 1 mm steps
e.g., 0300 = 50 ... 300 mm
16
17
18
3.2 Device variants
The device is available in the following variants:
•M12 male connector (4-pin) or 3-wire PUR cable
3 PRODUCT DESCRIPTION
8T E C H N I C A L I N F O R M A T I O N | MAX48 8021473/2017-08-08 | SICK
Subject to change without notice

3.3 Construction and function
Construction of the device
12 3 4
Figure 1: Construction of the MAX48
1M12 connector system
2Protective housing (electronics)
3Position magnet
4Pressure pipe
Connector system:
The M12 connector system requires very little time to attach. It is suitable for applica‐
tions in harsh environments up to IP69K (when using a suitable mating connector).
Protective housing (electronics):
The housing is designed to be installed in a hydraulic cylinder and protects the sensor
electronics against external influences.
Position magnet:
This is the only moving component in the measuring device when installed in the pis‐
ton. The position magnet is located inside the piston and moves over the pressure pipe
without contacting it. The magnet field thereby produced identifies the current position
of the piston.
Pressure pipe:
Pressure-resistant construction - is inserted in the piston rod of the cylinder. It contains
the hermetically protected magnetostrictive sensing element.
Principle of operation
21
3
4
5
6
7
Figure 2: Schematic of the magnetostrictive measurement principle
1Magnet field of the current pulse
2Magnet field of the position magnet
3Magnetostrictive sensor component
4Current pulse
5Sound wave converter
PRODUCT DESCRIPTION 3
8021473/2017-08-08 | SICK T E C H N I C A L I N F O R M A T I O N | MAX48 9
Subject to change without notice

6Structure-borne sound wave
7Position magnet
The device operates on the magnetostrictive measurement principle that records the
actual path of a position magnet:
The radial magnet field (1) generated by the current pulse (4) interacts with the magnet
field (2) of the position magnet (7).
As a result of the interaction of the two magnet fields, a wave (ultrasonic) (6) is pro‐
duced in the magnetostrictive sensor component (3). This travels to the converter (5)
and the sensor electronics produce an electrical output signal.
The time interval between the current pulse and the detection of the structure-borne
sound wave is measured and enables the precise position of the magnet – which
changes as the cylinder moves – to be determined. As this measurement principle does
not require a reference point, no recalibration is necessary for this type of device.
The device is also maintenance-free as a result of the non-contact measurement.
3 PRODUCT DESCRIPTION
10 T E C H N I C A L I N F O R M A T I O N | MAX48 8021473/2017-08-08 | SICK
Subject to change without notice
Altri manuali per MAX48
1
Indice
Altri manuali SICK Accessori

SICK
SICK MRS1000 Manuale utente

SICK
SICK SureSense HL18 Series Manuale utente

SICK
SICK RSB Manuale utente

SICK
SICK MPS-G 1108675 Manuale utente

SICK
SICK GRTB18V Manuale utente

SICK
SICK LD-LRS Manuale utente

SICK
SICK MPS-G Manuale utente

SICK
SICK LD-MRS 400001S01 Manuale utente

SICK
SICK OL1 Manuale utente

SICK
SICK GRTE18 Manuale utente

SICK
SICK OLS20 Manuale utente

SICK
SICK deTem4 Core Ex Manuale utente

SICK
SICK SIM2000ST Manuale utente

SICK
SICK TiM35x Manuale utente

SICK
SICK VISIC100SF Manuale utente

SICK
SICK GSE6L Series Manuale utente

SICK
SICK HTE18 Series Manuale utente

SICK
SICK CQF16 Manuale utente

SICK
SICK PowerProx WTT190L-K Series Manuale utente

SICK
SICK WLA26 00 Series Manuale utente