Main Function
Three Main Button: +/MAX/MIN; -/C/F; ALERT
℃/℉changeable
Indoor temperature testing scope:32℉~122℉(0℃~50℃)
Indoor humidity testing scope:20%~95%
Outdoor temperature testing scope:-58℉~122℉(-50℃~50℃)
Temperature testing cycle: 30 seconds
Outdoor with 3 channels (OUT-1, OUT-2, OUT-3)
Temperature and humidity with Max/Min function
Manual clearing of Max/Min data
Outdoor temperature with alarm function
Product overview
1 –Channel indicator 2 –Alarm symbols with up limit and down limit
3 –Temperature 4 –Max/Min indicator
5 –Sensor reception indicator 6 –Humidity
7 –+ /MAX / MIN button 8 –- / °C / °F button
9 –ALERT button 10 –Stand
11 –Battery compartment with battery cover

Manual –WS 7060
- EN02 -
Outdoor sensor
A –Sensor number (same as default channel setting) B –Wall mounting hole
C –Channel switch (default set to sensor number) D –Battery cover
E –Battery compartment F –Stand
Initial operation
- Slide the battery cover off the battery compartment of all sensors and the main station.
- Make sure that the set number on the channel switch is the same as sensor number on front of sensor.
- Insert 2 x AAA batteries into the battery compartment of each of the outdoor sensors.
- Insert 2 x AAA batteries into the battery compartment of the main station.
- Slide the battery cover back onto the battery compartments of all outdoor sensors and the main station.
- When fully powered, the display on the main station will show all symbols for 2 seconds and then change into
sensor receiving mode for 3 minutes. Keep the sensors close to the main station until all channels display

Manual –WS 7060
- EN03 -
values. Outdoor sensors can be placed away from the main station as soon as all channels are receiving
values.
Note:
Should the sensor reception fail after 3 minutes, the reception symbol of the specific channel will disappear.
In this case, restart initial operation with a set of fresh and full batteries until all sensors can be connected.
Temperature alarm setting
- In normal display mode, press the Alert button for 3 seconds to enter alert setting mode
- In alert setting mode, press the +or –button to select an outdoor channel.
- Press the Alert button to confirm the selected channel. The down limit symbol is blinking.
- Press the +or –button to change the value of the down limit.
- Press the Alert button to confirm the alert changes. The up limit symbol is blinking.
- Press the +or –button to change the value of the up limit.
- Press the Alert button to confirm the alert changes. The up&down limit symbol is blinking.
- Press the +or –button to activate the alarm and the alarm symbol is blinking. Press the +or –button
again to deactivate the alarm and alarm symbol is no longer displayed.
- Press the Alert button to confirm the alert changes and exit the alert setting mode.
Note:
- The alarm symbol will be permanently displayed in the corresponding channel as long as the alarm stays
activated.
- Down limit default value is 0 ℃, up limit default value is 35℃.
- In alert setting mode, it will be exit when there is no any operation in 20 seconds
- In alert setting mode, press the +or –button once to change value by 1 unit or hold the +or –button to quicker
adjust the value.
Temperature alarm
- This station has an up limit & down limit for 3 alarms, one for each outdoor channel.
- If temperature reaches a limit, is higher then up limit or below down limit, then the or and the
symbols will flash and the alarm will sound.
- While alarming, press any button to stop the alarm sound, but the symbol will still be flashing. The alarm
sound will also turn off automatically after 1 minute, if no button is pressed.
- The symbol will no longer blink and become permanent again, once the temperature value is no longer at
or beyond the set temperature limit.
Note
- The alarm can permanently be deactivated by using the temperature alearm setting.

Manual –WS 7060
- EN04 -
Outdoor sensor reception
- While doing initial operation or manual reception, the outdoor reception mode will be entered for 3 minutes and
the reception symbol will flash.
- Press the –button for 3 seconds to start outdoor reception mode manually.
- The outdoor reception mode was successful once every channel displays values and the reception symbol
will be displayed permanently on the display.
Note:
- When sensor data in each channel not receives the same ID code within one hour, the channel will display the
last received value flashing, then enter 3 minutes outdoor receiving mode. After one hour, it will clear ID code
then enter 3 minutes RF receiving mode, at this time the display in which channel will display --.-, clearing the
Max/Min value. It will repeat until a signal is received.
- When the sensor data was lost, but the signal received again, the sensor date will be displayed and the
MAX/MIN value recorded
MIN/MAX values
- The lowest and highest values in each channel will be recorded and can be displayed at any time.
- In normal display mode, press the +/MAX/MIN button once to display the MAX values in each channel.
- Press the +/MAX/MIN button once again to display the MIN values.
- Press the +/MAX/MIN button once again to return to normal display mode.
- To clear all recorded values, press the +/MAX/MIN button for 3 seconds and the values on the display will
vanish for 1 second to indicate successful MAX/MIN clearing.
Displayed Temperature unit
- In normal display, press the -/C/F button to change the temperature unit between °C and °F.
Temperature and humidity range
- Indoor temperature scope: 32℉~122℉(0℃~50℃)
- Testing cycle: 30 seconds
- Outdoor temperature scope: -58℉~122℉(-50℃~50℃)
- Indoor/Outdoor humidity scope: 20%~95%
- When temperature value higher than scope it will display HH.H and when temperature lower than scope it will
display LL.L.
- When humidity value higher than scope it will display 95% and when humidity lower than scope it will display
20%.
Low battery indicator
When batteries in outdoor sensors or the main station are starting to run low on energy, the low battery indicator

Manual –WS 7060
- EN05 -
will be displayed in the corresponding section on the display. This symbol indicates that the batteries in this specific
sensor or station should be changed as soon as possible.
Environmental reception effects
Same as all wireless devices, the reception of the station is maybe affected by the following circumstances:
long transmitting distance
among tall buildings
inside concrete buildings
near electrical appliances (computers, TV’s, etc) and metallic structures
inside moving vehicles
Place the station at a location with optimal signal, i.e. close to a window and away from metal surfaces or electrical
appliances.
Keep in mind that the outdoor transmitter only has the optimal transmission range in open area with no
obstructions. Each obstruction between the transmitter and the station (roof, walls, floors, ceilings, thick trees, etc.)
will effectively cut the transmission range in half.
Precautions
This main unit is intended to be used only indoors.
Do not subject the unit to excessive force or shock.
Do not expose the unit to extreme temperatures, direct sunlight, dust or humidity.
Do not immerse in water.
Avoid contact with any corrosive materials.
Do not dispose this unit in a fire as it may explode.
Do not open the inner back case or tamper with any components of this unit.
Batteries safety warnings
Use only alkaline batteries, not rechargeable batteries.
Install batteries correctly by matching the polarities (+/-).
Always replace a complete set of batteries.
Never mix used and new batteries.
Remove exhausted batteries immediately.
Remove batteries when not in use.
Do not recharge and do not dispose of batteries in fire as the batteries may explode.
Ensure batteries are stored away from metal objects as contact may cause a short circuit.
Avoid exposing batteries to extreme temperature or humidity or direct sunlight.
Keep all batteries out of reach from children. They are a choking hazard.
Use the product only for its intended purpose!
Consideration of duty according to the battery law
Old batteries do not belong to domestic waste because they could cause damages of health and environment.
You can return used batteries free of charge to your dealer and collection points. As end-user you are
committed by law to bring back needed batteries to distributors and other collecting points!
Consideration of duty according to the law of electrical devices
This symbol means that you must dispose of electrical devices separated from the General household waste
when it reaches the end of its useful life. Take your unit to your local waste collection point or recycling centre.
This applies to all countries of the European Union, and to other European countries with a separate waste
collection system.
Indice
Altri manuali Technoline Strumento di misura

Technoline
Technoline WS 9420 Manuale utente

Technoline
Technoline WL 1030 Manuale utente

Technoline
Technoline EA 3000 Manuale utente

Technoline
Technoline COST MANAGER Manuale utente

Technoline
Technoline WL 1025 Manuale utente

Technoline
Technoline COST MANAGER Manuale utente

Technoline
Technoline MA10402 Manuale utente

Technoline
Technoline Mobile Alerts MA10001 Manuale utente

Technoline
Technoline WZ 1200 Manuale utente

Technoline
Technoline WL 1045 Manuale utente