Tempsens CALsys 1700 Manuale utente

Temperature
Calibrator
(CALsys 1700)
User's Guide
TEMPSENS INSTRUMENTS (l) PVT. LTD. UNIT ll
A-190, Road No.5, M.I.A., Udaipur-313003 INDIA
Ph. : +91-294-3500600,
Fax : +91-294-3500631
Email : tech@tempsens.com
Web : www.tempsens.com

Page | 1
Legal Disclaimer
The information contained in this document is the property of TEMPSENS.
TEMSPENS reserves the right to make changes to this document and to the product described herein
without notice. Before installing and using the product, review the latest version of the applicable
documentation, which are available from the Tempsens website at:
http://www.tempsens.com/
© 2021 Tempsens Instrument Pvt. Ltd. All Rights Reserved.
Document Information
Name
Temperature Calibrator (CALsys 1700) User Manual
Document Version
1.0
Document Code
TS.CS.004
Publish Date
Saturday, December 11, 2022

Page | 2
Preface......................................................................................................................................... 5
Safety Information.................................................................................................................. 5
Electrical Safety....................................................................................................................... 6
Health and Safety Instructions................................................................................................ 7
Cautions and Preventions....................................................................................................... 8
Document Conventions........................................................................................................... 8
Chapter 1
Introduction................................................................................................................................. 9
1.1 About CALsys 1700.................................................................................................................. 9
1.2 Basic Working Model of CALsys 1700...................................................................................... 10
1.3 Physical Measurements.......................................................................................................... 11
1.4 Wiring Diagram....................................................................................................................... 12
1.5 Technical Specifications for CALsys 1700 BB ......................................................................... 13
1.6 Technical Specifications for CALsys 1700L ............................................................................. 14
Chapter 2
Setting Up CALsys 1700................................................................................................................. 15
2.1 Installation.............................................................................................................................. 15
2.2 Optimal Environmental Conditions......................................................................................... 15
2.3 Unpacking and Initial Inspection............................................................................................. 16
2.4 Operating Instructions............................................................................................................ 17
Chapter 3
Operating CALsys 1700.................................................................................................................. 18
3.1 Turning On the Unit................................................................................................................. 18
3.2 Heating Up the Source............................................................................................................ 19
3.3 Operating Instructions............................................................................................................ 19
3.4 Cooling Down the Source ....................................................................................................... 20
Table of Contents

Page | 3
Chapter 4
Operating Unit Controller.............................................................................................................. 21
4.1 Operation of Controller........................................................................................................... 21
4.2 Wiring Layout of Controller..................................................................................................... 22
4.3 The temperature Controller.................................................................................................... 22
4.4 Altering the Set Point ............................................................................................................. 23
4.5 Monitoring the Controller Status ........................................................................................... 23
4.6 Temperature Units ................................................................................................................. 23
Chapter 5
Digital Communication................................................................................................................. 24
5.1 Digital Communications Wiring............................................................................................... 24
5.2 Digital Communications Parameters....................................................................................... 25
Chapter 6
Software Installation..................................................................................................................... 26
6.1 Installation.............................................................................................................................. 26
6.2 Parameters on main screen.................................................................................................... 27
Chapter 7
Service & Maintenance................................................................................................................. 28
7.1 Routine Service....................................................................................................................... 28
7.2 Replace the Controlling Sensor............................................................................................... 28
7.3 Replace Solid State Relay......................................................................................................... 28
Chapter 8
Troubleshooting CALsys 1700........................................................................................................ 30
8.1 CALsys 1700 unit does not turn on......................................................................................... 30
8.2 CALsys 1700 unit is not stable................................................................................................. 30
8.3 The temperature of the calibrator does not rise..................................................................... 30

Page | 4
Appendix A : Calibration Services ................................................................................................. 31
In House Calibration Facility.................................................................................................... 31
On-site Calibration Facility...................................................................................................... 32
Fixed-Point Calibration Facility................................................................................................ 32
Appendix B : Warranty ................................................................................................................. 33
Limit of Liability....................................................................................................................... 33
Caution in Using the Product.................................................................................................. 33

Page | 5
Preface
Welcome to the Temperature Calibrator (CALsys 1700) user guide. This guide provides detailed information
about all the product options and features, and explains how to use the product and configure basic settings
to suit your requirements.
This user manual contains information about the product and its proper use and should be kept in a place
where it will be easy to access. This user manual also provides safety precautions in using this product.
Safety Information
This chapter contains important information for the safety. If the instructions contained are not followed
properly, particularly the safety guidelines, it could result in serious personal injury or can cause serious
damage to the unit and to the components of system it is connected to. Use the instrument only as specified
in this manual. Otherwise, the protection provided by the instrument may be impaired.
Refer to the safety information below and throughout the manual.
In order to assure the device operates safely, the operator needs to act effectively and be conscious of safety
problems.
The terms “Warning” and “Caution” have the following definition:
l"Warning" indicates conditions or behaviors that could endanger the user.
l"Caution" denotes situations or behaviors that may endanger the instrument in use.
The following safety symbols may appear on CALsys 1700 unit:
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
Risk of Danger. Important
information. See Manual
Hazardous voltage. Risk of electric shock
Caution, Hot Surface
Protective Earth Ground

Page | 6
Electrical Safety
lBefore using this equipment, make sure it is properly grounded. Make sure the ground conductor
wire (colored green/yellow) in the main power cable is connected to a protective earth/ground. If
the equipment is not properly grounded, the high voltage may flow through the equipment body
(chassis). If safety procedures are not followed, SEVERE INJURY OR DEATH may occur.
lDo not remove the panels from the equipment without proper safety measures to avoid internal
main power supply voltage hazard.
WARNING:
Follow these precautions to avoid electric shock or personal injury:
This equipment uses protective earth circuit to ensure that the conductive parts do not store electric
charges or conduct electricity if insulation fails
lBefore connecting the equipment to the electricity supply, understand the parts of the calibrator with
the help of operating manual.
lUse power cables only with appropriate voltage and power rating, and that are approved for usage in
your country.
lReplace the main power cable if the insulation is damaged, or if the insulation shows signs of wear and
tear.
lDO NOT put the product at the location where access to the main power is blocked.
lDO NOT use an extension cord or adapter plug.
lDO NOT use the product if it operates incorrectly.
lMake sure the power cord does not touch the hot parts of the product.

Page | 7
Health and Safety Instructions
WARNING: BURN HAZARD - DO NOT touch the well access surface of the unit at high temperature
To avoid possible health and safety concerns, follow these guidelines.
lWear appropriate protective clothing before using the equipment.
lOperators of this equipment should be adequately trained in the handling of hot and cold items and
liquids.
lDo not use the apparatus for jobs other than those for which it was designed, that is, the calibration of
thermometers.
lDo not handle the apparatus when it is hot (or cold), without wearing the appropriate protective
clothing and having the necessary training.
lDo not drill, modify or otherwise change the shape of the apparatus.
lDo not use the apparatus outside its recommended temperature range.
lAfter use, do not return the apparatus to its carrying case until the unit has cooled down.
lThere are no user serviceable parts inside. When required, contact Tempsens agent for repair.
lEnsure all materials, especially flammable materials are kept away from the hot parts of the apparatus,
to prevent fire risk.
lDo not use the product around explosive gas, vapor, or in damp or wet environments.
lMake sure that the space around the product meets minimum space requirements.
lDO NOT turn off the unit at temperatures higher than 350°C. This could create a hazardous situation.
Select a set-point less than 100°C and allow the unit to cool before turning it off.
lThe top sheet metal of the furnace may exhibit extreme temperatures for areas close to the well
access.
lMaterials used in this furnace may be irritating to skin, eyes, and respiratory tract. Consult the material
manufacturer's Material Safety Data Sheet (MSDS) to learn about those materials before using.

Page | 8
Cautions and Preventions
To avoid possible damage to the instrument, follow these guidelines:
lBefore working inside the equipment, turn the power off and disconnect the power cord.
lDO NOT turn the unit upside down with the inserts in place; the inserts will fall out of the unit.
lUse of this instrument at HIGH TEMPERATURES for extended periods of time requires caution.
lCompletely unattended high temperature operation is not recommended for safety reasons.
lDO NOT plug the unit into 230 V if the heater switches and fuse holder reads 115 V. This action will
cause the fuses to blow and may damage the instrument.
lComponents and heater lifetime can be shortened by continuous high temperature operation.
lDO NOT use fluids to clean out the well.
lNever introduce foreign material into the probe hole of the insert. Fluids and other materials can leak
into the calibrator causing damage.
lDO NOT drop or force the probe stems into the well. This type of action can cause a shock to the sensor
and affect the calibration.
Document Conventions
The documentation uses the following conventions.
Note:
Configuration notes
Tip:
Recommendations or suggestions
Important:
Information regarding required or default configuration settings and product
limitations
WARNING:
Critical actions and configuration options
WARNING:

Page | 9
Chapter 1
Introduction
The CALsys 1700 used as calibrator for thermocouple calibration and it can be also used as a pyrometer
calibration with ceramic cavity.
The 'CALsys 1700' has been designed to provide stable and accurate temperature to enable professionals to
calibrate Temperature Sensing Devices (Thermocouple & pyrometer) by comparison method up to a
temperature range of 1700°C. The 'CALsys 1700L' model has been designed to be rugged and easily
maintained. This model provides an isothermal enclosure (Ceramic block) in which the thermocouple can
be calibrated against the temperature of the calibrator.
The 'CALsys 1700BB' model has been designed in single part. This model provides an isothermal enclosure
in which the Non-contact pyrometers can be checked against the temperature of the black body. For
traceable calibration a master pyrometer should be used. The units' features emissivity of 0.99, thus
offering the closest approximation of a target surface that is a perfect emitter of infrared energy.
1.1 About CALsys 1700
Back View Front View
Altri manuali per CALsys 1700
1
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Tempsens Apparecchiature di prova
Manuali Apparecchiature di prova popolari di altre marche

SMART
SMART KANAAD SBT XTREME 3G Series Manuale utente

Agilent Technologies
Agilent Technologies BERT Serial Manuale utente

Agilent Technologies
Agilent Technologies N3280A Manuale utente

Vernier
Vernier Go Direct Voltage Manuale utente

Lifeloc
Lifeloc R.A.D.A.R. Manuale utente

Fluke
Fluke T5-600 Istruzioni per l'uso e l'installazione