TERRY Lifestyle 3.6m Manuale utente

Model 3.6m
User Manual
Original instructions

CONTENTS
Introduction 3
Description 4
General Do’s and Don’ts 5
Controls and operation 7
Smoke alarms 9
Emergency procedures 11
Fault finding 19
Changing smoke alarm batteries 21
Changing call station batteries 22
Safety feature check 23
Service history record 24
Declaration of conformity 25
Lift specification sheet 26
2

3
INTRODUCTION
Thank you for choosing the Lifestyle Lift, designed and
manufactured in the U.K. using the latest technology by Terry
Group Ltd. We want you to get the most out of your Lifestyle Lift
and to help in this aim we have produced this small booklet on
operation and maintenance of the equipment, which we hope you
will find helpful.
It is hoped that any queries you may have during day to day
operation will be answered in the text, but if you do have any
problems, technical assistance is only a phone call away.
We hope our product gives you many years of reliable service.
Peter Morrey
Managing Director

4
DESCRIPTION
The Lifestyle Lift is an inter floor lift that is designed for use by up
to two people standing or one person seated travelling between
fixed floor levels in private dwellings.
With a maximum carrying capacity of 250kg, this lift is not
intended for use as a means of transporting goods.
The lift is designed to operate without a lift shaft and is provided
with an automatic infill panel which makes the ceiling aperture
safe when the lift is parked downstairs.
Optional GPRS two way communications or a hard wired
standard telephone can be supplied in the car for emergency
communication.
A standard feature is the provision of half hour fire rated panels in
both the aperture infill and the car underpan.
The lift car panels are made from powder coated steel which can
easily be cleaned using normal household cleaners. Upholstery
is made from high quality contract materials and can be cleaned
in the same way.

GENERAL DO’S AND DON’TS
• Never switch off the power supply to the lift, even when you go
away. The lift control circuits are fed by a battery, which must be
kept on constant charge.
• The lift should always be returned to the lower level when
not in use. If it is left upstairs for prolonged periods, it will
occasionally re-level itself depending on conditions. The lift must
be left at the lower level if the mains is turned off.
• Keep hold of the door whether opening or closing.
• Always close the door after using the lift.
• Never allow children to play in, under or around the lift. If
children are in the house, always isolate the lift using the
optional remote control fob, see page 7.
• Ensure that the area under the lift is kept clear. The underpan
surface is fitted with sensors, which automatically stop the lift if it
strikes an object (see pg.6).
• Always keep the key fob, if supplied and emergency release
key in a safe place near the lift. The in-car release keys behind
the centre cover should not be removed unless there is an
emergency.
• Do not place any object on the aperture infill or stand on it when
the lift is in operation. Ensure that as far as practical, the area
around the travelling infill panel is clear of persons (particularly
children) when the lift is being operated. The infill panel is fitted
with sensors that automatically stop the lift if the infill panel is
obstructed (see pg.6)
• Only use the lift for transporting up to 2 people standing
or 1 seated between fixed floor levels. Do not use for the
transortation of goods.
• Always treat your lift with the respect that should be shown to
electrical and mechanical equipment.
• Safety related components should only be adjusted and reset
by a competent person.
5

6
The diagram below shows the position of the sensors on the lift,
designed to prevent injury or damage if the movement of the
carriage is obstructed.
Infill panel safe edge
(sensors on upper
and lower surfaces)
Underpan safe edge
(sensor on lower and
upper surface)
Lift shown part-way
through aperture
Plastic car upper
safe edge

CONTROLS AND OPERATION
There are two wall mounted call stations, one at each level (see
illustration) and a similar control station fitted in the lift car.
The lift can be isolated by using the optional remote control fob.
When the lift is isolated none of the control stations will function.
The call and control stations can only be activated by using the
remote fob. When the lift is activated, the coloured indicator lights
in the car will illuminate.
The lights in the car will switch on automatically when any call or
control button is pressed and will automatically turn off after a few
minutes.
General operation
Call the lift by pressing the up arrow or down arrow button on
either call station and wait for it to stop. The door will unlock and
can then be manually opened. Press and release UP or DOWN
on the control station for the lift to travel uninterrupted to the
next floor. If the lift does not start, check that the door is properly
closed and try again. Always close the door after using the lift.
Leave the lift downstairs whenever possible.
STOP
UP
DOWN
DOOR
7
Wall mounted call station
Optional remote
isolate fob

8
Car light intensity control
On one of the call stations, by pressing and holding the stop and
down buttons, the light intensity will reduce. By pressing holding
the stop and up buttons, the light intensity will increase. When
the desired level is reached, release the buttons.
Car light timer
It is possible to vary the length of time the car light stays on after
the last operation on the lift.
By pressing and holding the stop and up and door buttons, the
light timer will automatically sequence through the light-on times
and respond with a series of beeps. Each beep represents five
minutes in time. When the desired time is reached release all
buttons.
Radio remote call stations
The call stations and the optional remote control are fully
integrated units with internal batteries. The batteries can be
changed by the user with a philips screwdriver on the back of
each unit.
CR2450 (550 mAh minimum) are approved for use with these
devices.
CRITICAL:
It is critical that all three batteries are replaced with NEW ones of
the same type, manufacture and age, that they are fitted at the
same time and that they are correctly oriented.

SMOKE ALARM
If smoke detection system has been installed on your lift. It has
been designed to provide adherence to British Standard BS5900
2012 Section 9.13 “Behaviour of homelift in the event of fire”.
The system utilises two smoke alarms one upper level, one lower
level, which are wirelessly connected to the lift (see illustration
below).
The Smoke Alarm unit comprises two parts, the first (TOP PART)
being a Smoke alarm unit. This is the Smoke detection unit and
contains an integral battery with a 10 year life span. This is not
replaceable.
The second part (BASE UNIT) contains the radio transmitter
receiver unit. Power to this unit is supplied by two AA style
batteries. The voltage level of the batteries is monitored.
In the event of a low battery, a sounder in the carriage will beep
(see Fault Finding pg.20). If the batteries are not replaced, the lift
will be taken out of service.
Radio smoke alarm operation
When installed on a Harmony Lift, the smoke alarm system will
cause the lift to deactivate safely once the alarm is triggered.
When deactivated, the door will continue to operate as normal.
9
Mute/test button
Smoke Alarm (TOP PART)
Radio Transmitter/receiver
Unit (BASE UNIT)

10
When the Lift is stationary at either level:
If smoke is detected, the alarm will sound. After a period of time,
all other smoke alarms connected to the system will then start to
sound and the lift deactivates.
When the Lift is travelling between levels:
If smoke is detected, the alarm will sound. After a period of time,
all other smoke alarms connected to the system will then start to
sound.
The lift will continue to its requested level, it will remain possible
(until that level is reached) to change the direction of the lift.
Once at the desired level, the lift will deactivate.
Reactivation of Lift
The lift will automatically reactivate when the smoke alarm no
longer detects smoke and a period of two minutes has expired.
Silencing the Smoke Alarms
In either situation, it is possible that the sounder of each
individual alarm can be silenced. The alarms that has been set
off remotely can be silenced by pressing the both the STOP and
DOOR button on one of the lift handsets. Then the alarm that
has been triggered by the smoke can be silenced by pressing
the mute button on the alarm itself. Doing this will silence the
alarms for four minutes. When silenced, the lift will automatically
reactivate when a period of two minutes has expired. If the
source of smoke is not removed, the smoke alarms will begin to
sound again and the lift will be disabled.
Indice
Altri manuali TERRY Sistema di sollevamento

TERRY
TERRY HARMONY 2 Series Manuale utente

TERRY
TERRY TSL1000 Manuale utente

TERRY
TERRY Melody 2 hydraulic MK2 Manuale utente

TERRY
TERRY HARMONY Manuale utente

TERRY
TERRY 1100W TSL1 Manuale utente

TERRY
TERRY Melody 1 Manuale utente

TERRY
TERRY Lifestyle Manuale utente

TERRY
TERRY Harmony Series 2 Homelift Manuale utente
Manuali Sistema di sollevamento popolari di altre marche

Genie
Genie Z-60/34 Manuale utente

Screen Technics
Screen Technics INTERFIT Vertical Up Lift Manuale utente

Mortuary Lift
Mortuary Lift ULTIMATE 1000 Manuale utente

Custom Equipment
Custom Equipment Hy-Brid 3 Series Manuale di programmazione

Custom Equipment
Custom Equipment Hy-Brid Lifts 2 Series Manuale di programmazione

Hy-Brid Lifts
Hy-Brid Lifts HB-P3.6 Manuale di programmazione