TESTO 330i Manuale utente

testo 330i · Flue gas measuring instrument
testo 330i LX · Flue gas measuring instrument
Instruction manual

2

1 Contents
3
1Contents
1Contents ...................................................................................................3
2Safety and the environment....................................................................6
3Use ............................................................................................................6
4Product description.................................................................................8
4.1. Measuring instrument ......................................................................8
4.1.1. Overview..........................................................................................................8
4.1.2. Terminal panel left/right ...................................................................................9
4.2. Modular flue gas probe..................................................................10
5First steps ..............................................................................................11
5.1. Commissioning ..............................................................................11
5.2. Getting to know the product...........................................................11
5.2.1. Connecting probes.........................................................................................11
5.2.2. Mains unit/rechargeable battery.....................................................................11
5.2.2.1. Charging the rechargeable battery ..................................................11
5.2.2.2. Mains operation...............................................................................12
5.2.3. Switching on and connecting with a mobile terminal device...........................12
5.2.4. Switching off ..................................................................................................13
5.2.5. Using the App ................................................................................................14
6Using the product ..................................................................................15
6.1. Performing settings........................................................................15
6.1.1. Configuring measurements.....................................................................15
6.1.2. Graphics ........................................................................................................16
6.1.3. | Instrument settings | Language............................................................16
6.1.4. | Instrument settings | Country version...................................................17
6.1.5. | Instrument settings | Sensor diagnosis ................................................17
6.1.6. | Instrument settings | Sensor protection................................................17
6.1.7. | Instrument settings | O2reference........................................................17
6.1.8. | Instrument settings | O2addition ..........................................................17
6.1.9. | Instrument settings | Height compensation ..........................................17
6.1.10. | Instrument settings | Switching the testo 330i off .................................18

1 Contents
4
6.2. Measuring ..................................................................................... 18
6.2.1. Preparing for measurement ........................................................................... 18
6.2.1.1. Checking the condensate container fill level.................................... 18
6.2.1.2. Checking the particle filter ............................................................... 18
6.2.1.3. Zeroing phases................................................................................ 18
6.2.1.4. Performing a gas path check........................................................... 19
6.2.1.5. Installing the probe mount testofix® ................................................ 19
6.2.1.6. Using the modular flue gas probe.................................................... 21
6.2.2. | Flue gas ................................................................................................ 22
6.2.3. | Draught ................................................................................................. 23
6.2.4. | COundiluted .......................................................................................... 23
6.2.5. | Smoke number ...................................................................................... 23
6.2.6. | Differential pressure .............................................................................. 23
6.2.7. | Differential temp. ................................................................................... 24
6.2.8. | O2supply air .......................................................................................... 24
6.2.9. | Gas flow rate ......................................................................................... 24
6.2.10. | Oil flow rate ........................................................................................... 25
6.3. Printing readings ........................................................................... 25
6.4. Report ........................................................................................... 26
6.4.1. Add to protocol (save measurement) ............................................................. 26
6.4.2. Finish protocol ............................................................................................... 26
7Maintaining the product ....................................................................... 28
7.1. Checking instrument status........................................................... 28
7.1.1. | Instrument settings | Sensor diagnosis ................................................ 28
7.1.2. | Error list ............................................................................................... 28
7.2. Cleaning the measuring instrument .............................................. 28
7.3. Draining the condensate container ............................................... 28
7.4. Opening the measuring instrument............................................... 29
7.5. Replacing the rechargeable battery .............................................. 33
7.6. Replacing sensors ........................................................................ 33
7.7. Cleaning the modular flue gas probe ............................................ 34
7.8. Replacing the probe module ......................................................... 35
7.9. Checking/replacing the particle filter ............................................. 35
7.10. Changing the thermocouple.......................................................... 36
7.11. Updating the instrument software ................................................. 37

1 Contents
5
8Technical data........................................................................................38
8.1.1. Examinations and licenses ............................................................................38
8.1.2. Bluetooth®module .........................................................................................38
8.1.3. Measuring ranges and resolution...................................................................42
8.1.4. Accuracy and response time..........................................................................42
8.1.5. Other instrument data ....................................................................................44
8.1.6. Declaration of conformity ...............................................................................45
9Tips and assistance...............................................................................46
9.1. Questions and answers .................................................................46
9.2. Contact and Support......................................................................48
9.3. Accessories and spare parts .........................................................48

3 Use
6
2Safety and the environment
Please note the information in the document Commissioning and
Safety (printed version supplied with the product). Make sure that
all product users read and observe the safety information!
3Use
testo 330i und test o 330i LX
The testo 330i / testo 330i LX is a flue gas measuring instrument
which in combination with a separate Android or iOS mobile device
and the testo 330i App enables professional flue gas analysis of
combustion systems:
• Small combustion systems (oil, gas, wood, coal)
• Low-temperature and condensing boilers
• Gas water heaters
These systems can be adjusted using the instrument and checked
for compliance with the applicable limit values.
The instrument has been verified as a short-term measuring
instrument and should not be used as a safety (alarm) instrument.
The following tasks can also be carried out using the instrument:
• Regulating the O2, CO and CO2, NO, NOxvalues in furnaces for
the purpose of ensuring optimal operation.
• Draught measurement.
• Measuring and regulating the gas flow pressure in gas water
heaters.
• Measuring and optimising the flow and return temperatures of
heating systems.
• Ambient measurement - CO and CO2.
• Detection of CH4(methane) and C3H8(propane).
• The instrument can be used for measurements on combined
heat and power stations (CHP) in accordance with the
first German Federal Immission Control Ordinance (BImSchV).
• In principal, the CO sensor can also be used for
measurements on CHP stations. If you should carry out
more than 50 measurements on CHP stations per year,
please contact your nearest Testo service centre or send
the testo 330i to testo Service for inspection.
A worn NOxfilter of the CO sensor can be ordered as a
spare part (item no. 0554 4150) and replaced.

3 Use
7
Testo guarantees the functionality of its products when
used in accordance with their intended purpose. This
guarantee does not apply to features of Testo products in
combination with unauthorised third-party products.
Competitor products are not authorised by Testo.
As is common practice, Testo generally excludes support,
warranty or guarantee claims relating to functionality that
has not been guaranteed by Testo as part of the product
offered. Claims shall also be excluded in the event of
improper use or handling of the products, e.g. in
combination with unauthorised third-party products.
The use of the wireless module is subject to the regulations and
stipulations of the respective country of use, and the module may only
be used in countries for which a country certification has been granted.
The user and every owner has the obligation to adhere to these
regulations and prerequisites for use, and acknowledges that the re-
sale, export, import etc. in particular in countries without wireless
permits, is his responsibility.

4 Product description
8
4Product description
4.1. Measuring instrument
4.1.1. Overview
1 Retaining bracket: for attaching to the probe mount testofix®
2 Terminal panel left
3 Status LEDs:
LED Display Meaning
Blue Off Instrument off or not ready
Flashes (0.05 s
on/0.5 s off)
Instrument on, start up phase
Flashes (0.5 s
on/0.5 s off)
Instrument on, Bluetooth®Find
Device activated
Light is constant Instrument on, Bluetooth®
connection activated
Red Flashes (0.05 s
on/0.5 s off)
Device error
Flashes (0.5 s
on/0.5 s off)
Mains unit plugged in, battery
charging
Light is constant Mains unit plugged in, battery
fully charged
4 ON/OFF button
5 Condensate container, condensate outlet plug
6 Terminal panel right

4 Product description
9
7. Magnetic holder (on rear)
WARNING
Magnetic field
May be harmful to those with pacemakers.
> Keep a minimum distance of 15 cm between pacemaker and
instrument.
ATTENTION
Magnetic field
Damage to other devices!
>Keep a safe distance away from products that could be
damaged by the effects of magnetism (e.g. monitors,
computers or credit cards).
4.1.2. Terminal panel left/right
1 USB interface
2 Minus connection for differential pressure measurement
3 Mains unit socket
4 Flue gas socket
5 Probe socket

4 Product description
10
4.2. Modular flue gas probe
1 Removable filter chamber with window and particle filter
2 Probe module lock release
3 Probe module
4 Connector plug for measuring instrument
5 Probe handle
6 Connecting cable
Altri manuali per 330i
1
Indice
Altri manuali TESTO Strumento di misura

TESTO
TESTO 550 Manuale utente

TESTO
TESTO 0519.0816 Manuale utente

TESTO
TESTO 335 Manuale utente

TESTO
TESTO 320 Manuale utente

TESTO
TESTO 112 Manuale utente

TESTO
TESTO 110 Manuale utente

TESTO
TESTO 316-2-EX Manuale utente

TESTO
TESTO 175-T3 Manuale utente

TESTO
TESTO 6446 Manuale utente

TESTO
TESTO 0554 2222 Manuale utente