TESTO 417 Manuale utente

Instruction manual
Contents
General notes ....................................................18
1. Safety advice......................................................19
2. Intended purpose ..............................................20
3. Product description ............................................21
3.1 Display and control elements ........................................21
3.2 Voltage supply ..............................................................22
4. Commissioning ..................................................23
5. Operation ..........................................................24
5.1 Connecting a probe ......................................................24
5.2 Switching the instrument on / off ..................................24
5.3 Switching the display light on / off ................................24
5.4 Performing settings ......................................................25
6. Measuring ..........................................................27
7. Care and maintenance ......................................29
8. Questions and answers......................................30
9. Technical data ....................................................31
10. Accessories/spare parts ....................................31
testo 417
Vane anemometer
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

General notes18
General notes
This chapter provides important advice on using this
documentation.
The documentation contains information that must be
applied if the product is to be used safely and efficiently.
Please read this documentation through carefully and
familiarise yourself with the operation of the product before
putting it to use. Keep this document to hand so that you
can refer to it when necessary.
Identification
Representation Meaning Comments
Note Offers helpful tips and information.
±, 1, 2 Objective Denotes the objective that is to be
achieved via the steps described. Where
steps are numbered, you must always
follow the order given!
Condition A condition that must be met if an action
is to be carried out as described.
i, 1, 2, ... Step Carry out steps. Where steps are
numbered, you must always follow the
order given!
Text Display text Text appears on the instrument display.
Control button Press the button.
- Result Denotes the result of a previous step.
ºCross-reference Refers to more extensive or detailed
information.
Button
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

1. Safety advice 19
1. Safety advice
This chapter gives general rules which must be followed
and observed if the product is to be handled safely.
Avoid personal injury/damage to equipment
iDo not use the measuring instrument and probes to
measure on or near live parts.
iNever store the measuring instrument/probes together
with solvents and do not use any desiccants.
Product safety/preserving warranty claims
iOperate the measuring instrument only within the
parameters specified in the Technical data.
iAlways use the measuring instrument properly and for its
intended purpose. Do not use force.
iDo not expose handles and feed lines to temperatures in
excess of 70 °C unless they are expressly permitted for
higher temperatures.
Temperatures given on probes / sensors relate only to
the measuring range of the sensors.
iOpen the instrument only when this is expressly
described in the documentation for maintenance and
repair purposes.
Carry out only the maintenance and repair work that is
described in the documentation. Follow the prescribed
steps when doing so. For safety reasons, use only
original spare parts from Testo.
Ensure correct disposal
iTake faulty rechargeable batteries/spent batteries to the
collection points provided for them.
iSend the product back to Testo at the end of its useful
life. We will ensure that it is disposed of in an
environmentally friendly manner.
de
enfresitptsvnl????
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

2. Intended purpose20
2. Intended purpose
This chapter gives the areas of application for which the
product is intended.
Use the product only for those applications for which it was
designed. Ask Testo if you are in any doubt.
testo 417 is a compact measuring instrument for
measuring flow velocities and temperatures by means of an
integrated 100mm vane with temperature probe.
The product was designed for the following
tasks/applications:
· Measuring volumetric flow rates at inlets/outlets
· Measuring the temperature of flows
The product should not be used in the following areas:
· Areas at risk of explosion.
· Diagnostic measurements for medical purposes
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

3. Production description 21
3. Product description
This chapter provides an overview of the components of
the product and their functions.
3.1 Display and control
elements
Overview
Probe
Display
Control buttons
Battery compartment (rear)
Service compartment (rear)
Button functions
Button Functions
Switch instrument on;
switch instrument off (press and hold)
Switch display light on / off
Keep reading, display
maximum/minimum value
Open/leave configuration mode (press
and hold);
In configuration mode:
Confirm input
In configuration mode:
Increase value, select option
In configuration mode:
Reduce value, select option
Multi-point and timed mean calculation
Volumetric flow
de
enfresitptsvnl????
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

3. Production description22
Important displays
Display Meaning
Battery capacity (bottom right in display):
· 4 segments in the battery symbol are lit: Instrument battery is fully
charged
· No segments in the battery symbol are lit: Battery is almost spent
3.2 Voltage supply
Voltage is supplied by means of a 9V monobloc battery
(included in delivery) or rechargeable battery. It is not
possible to run the instrument from the mains supply or
charge a rechargeable battery in the instrument.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

4. Commissioning 23
4. Commissioning
This chapter describes the steps required to commission
the product.
²Inserting a battery/rechargeable battery:
1To open the battery compartment on the rear of the
instrument, push the lid of the battery compartment in
the direction of the arrow and remove it.
2Insert a battery/rechargeable battery (9V monobloc).
Observe the polarity!
3To close the battery compartment, replace the lid of
the battery compartment in position and push it
against the direction of the arrow.
de
enfresitptsvnl????
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

5. Operation24
5. Operation
This chapter describes the steps that have to be executed
frequently when using the product.
5.1 Connecting a probe
The necessary probes are permanently connected or
integrated. It is not possible to connect any additional
probes.
5.2 Switching the instrument
on / off
²Switching the instrument on:
iPress .
- Measurement view is opened: The current reading
is displayed, or ----- lights up if no reading is
available.
²Switching the instrument off:
iPress and hold (for approx. 2s) until the display
goes out.
5.3 Switching the display
light on / off
²Switching the display light on/off:
The instrument is switched on.
iPress .
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

5. Operation 25
5.4 Performing settings
1To open configuration mode:
The instrument is switched on and is in measurement
view. Hold, Max or Min are not activated.
iPress and hold (for approx. 2s) until the display
changes.
- The instrument is now in configuration mode.
You can change to the next function with .
You can leave configuration mode at any time. To do
so, press and hold (for approx. 2s) until the
instrument has changed to measurement view. Any
changes that have already been made in configuration
mode will be saved.
2To set funnel factor F.FACT:
For measurements at ventilation outlets with a funnel
the parameter F.FACT must be activated. The funnel
set (order no. 0563 4170) consists of a funnel for
measurements at plate outlets (200 x 200mm) and a
funnel for measurements at ventilation outlets (330 x
330mm).
Configuration mode is opened, F.FACT is lit.
iActivate (on) or deactivate (oFF) the factor with /
and confirm with .
3To set the area (only if F.FACT oFF):
Configuration mode is opened, AREA is lit.
iSet the cross-sectional area with / and
confirm with .
de
enfresitptsvnl????
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

5. Operation26
4To set the grill factor: K.FACT (only if F.Fact oFF):
If parts of the cross-sectional area are covered (e.g.
by grill members), this can be corrected via the grill
factor. The grill factor indicates the proportion of free
space on the cross-sectional area. Example: If 20% of
the area is covered, the grill factor must be set to 0.8
(80% free space)
Configuration mode is opened, K.FACT is lit.
iSet the grill factor with / and confirm with
.
5To set Auto Off:
Configuration mode is opened, AutoOff is flashing.
iSelect the desired option with / and confirm
with :
·on: The measuring instrument switches off
automatically if no button is pressed for 10min (Hold
or Auto Hold is lit).
· oFF: The measuring instrument does not switch
itself off automatically.
6To set the unit ofmeasurement:
Configuration mode is opened, UNIT is lit.
iSelect the desired unit of measurement with /
and confirm with .
7To reset:
Configuration mode is opened, RESET is lit.
iSelect the desired option with / and confirm
with :
·no: Instrument is not reset.
· Yes: Instrument is reset. The instrument is reset to
the factory settings.
- The instrument returns to measurement view.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Altri manuali per 417
3
Indice
Altri manuali TESTO Strumento di misura

TESTO
TESTO 755-1 Manuale utente

TESTO
TESTO 425 Manuale utente

TESTO
TESTO 460 Manuale

TESTO
TESTO 380 Manuale utente

TESTO
TESTO 6681 Profibus Manuale utente

TESTO
TESTO 635 Come usare

TESTO
TESTO 475 Manuale utente

TESTO
TESTO Saveris Manuale utente

TESTO
TESTO 625 Manuale utente

TESTO
TESTO 0638 1345 Manuale utente