Welker PP-1 Istruzioni per l'installazione e il funzionamento

INSTALLATION, OPERATION, ANDMAINTENANCEMANUAL
WELKER PITOT PROBE
MODELS
PP-1
PP-2
PP-3
PP-F
DRAWING NUMBERS
AD626BA
AD626BJ
AD843BD.1
PP1231
MANUAL NUMBER
IOM-101
REVISION
Rev. C, 1/3/2019

TABLEOFCONTENTS
2IOM-101 MODELS: PP-1, PP-2, PP-3, and PP-F REV: C 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331
Copyright © 2019Welker, Inc. All rights reserved. Welker®, W Welker®, W logo, WelkerScope®, WelkerJet®, and OdorEyes®are registered trademarks of Welker, Inc.
SAFETY 3
1. PRODUCT INFORMATION 4
1.1 Introduction 4
1.2 Product Description 4
1.3 Specifications 5
1.4 Equipment Diagrams 7
2. INSTALLATION & OPERATION 11
2.1 Before You Begin 11
2.2 Installation and Operation 11
2.3 Removing the Pitot Probe 12
3. MAINTENANCE 13
3.1 Before You Begin 13
3.2 Maintenance 14
3.3 Troubleshooting 14
APPENDIX 15
A: Referenced or Attached Documents 15

IMPORTANTSAFETYINFORMATION
READALLINSTRUCTIONS
Notes emphasize information and/or provide additional information to assist the user.
Caution messages appear before procedures that could result in damage to equipment if not observed.
Warning messages appear before procedures that could result in personal injury if not observed.
This manual is intended to be used as a basic installation and operation guide for the Welker Pitot Probes, PP-1, PP-2, PP-3, and PP-F. For comprehensive instructions,
please refer to the IOM Manuals for each individual component. A list of relevant component IOM Manuals is provided in Appendix A of this manual.
The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and maintenance of
the Welker equipment described in this manual. Correct installation and operation, however, are the responsibility of the end user. Welker reserves the right to make
changes to this manual and all products in order to improve performance and reliability.
BEFOREYOUBEGIN
Read these instructions completely and carefully.
IMPORTANT - Save these instructions for local inspector's use.
IMPORTANT - Observe all governing codes and ordinances.
Note to Installer - Leave these instructions with the end user.
Note to End User - Keep these instructions for future reference.
Installation of this Pitot Probe is of a mechanical nature.
Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the warranty.
If you received a damaged Pitot Probe, please contact a Welker representative immediately.
Phone: 281.491.2331
Address: 13839 West Bellfort Street
Sugar Land, TX 77498
SAFETY
3IOM-101 MODELS: PP-1, PP-2, PP-3, and PP-F REV: C 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

1.1 Introduction
We appreciate your business and your choice of Welker products. The installation, operation, and maintenance liability for this
equipment becomes that of the purchaser at the time of receipt. Reading the applicable Installation, Operation, and
Maintenance (IOM) Manuals prior to installation and operation of this equipment is required for a full understanding of its
application and performance prior to use.*
If you have any questions, please call Welker at 1-281-491-2331.
*The following procedures have been written for use with standard Welker parts and equipment. Assemblies that have been modified may have additional
requirements and specifications that are not listed in this manual.
1.2 Product Description
The Welker PP-1, PP-2, PP-3, and PP-F Pitot Probes are designed to create a product loop through a connected sampler or
sampling system.
When the product outlet and return of the unit are connected to a sampler or sampling system, the circulation pump and/or
kinetic energy from flow velocity create a circulation loop, a.k.a. hot loop. When in operation, product circulates through the hot
loop, continually presenting fresh product to the sampler or sampling system, allowing for collection of representative samples.
Welker may custom design the PP-1, PP-2, PP-3, and PP-F to suit the particular application and specifications of each customer.
SECTION 1: PRODUCTINFORMATION
4IOM-101 MODELS: PP-1, PP-2, PP-3, and PP-F REV: C 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

1.3 Specifications
The specifications listed in this section are generalized for this equipment. Welker can modify the equipment according to your
company's needs. Please note that the specifications may vary depending on the customization of your equipment.
Table 1: PP-1 Specifications
Products Sampled Gases and Liquids Compatible With the Materials of Construction
Material of Construction 316/316LStainless Steel
Maximum Allowable Operating Pressure
½" MNPT: 7700 psig @ -50 °F to 300 °F (530 barg @ -45 °C to 148 °C)
¾" MNPT: 7300 psig @ -50 °F to 300 °F (503 barg @ -45 °C to 148 °C)
1" MNPT: 5300 psig @ -50 °F to 300 °F (365 barg @ -45 °C to 148 °C)
Connections Pipeline: ½", ¾", or 1" MNPT
Product Inlet and Return: ¼" FNPT
InsertionDiameter ¼" (Standard)
³⁄₈"
Feature Scooped Tip on Inlet Probe
Options
45° Beveled Inlet Probe
Tungsten Carbide and Sulfinert®-Treated Sample Exposed Parts
CRNCertification
Table 2: PP-2 Specifications
Products Sampled Gases and Liquids Compatible With the Materials of Construction
Material of Construction 316/316LStainless Steel
Maximum Allowable Operating Pressure 3600 psig @ -20 °F to 120 °F (248 barg @ -28 °C to 48 °C)
Connections Pipeline: ½", ¾", or 1" MNPT
Product Inlet and Return: ¼" FNPT
InsertionDiameter ¼" (Standard)
³⁄₈"
Features Ball Valves
Scooped Tip on Inlet Probe
Options
45° Beveled Inlet Probe
Sulfinert®-Treated Sample Exposed Parts
Tungsten Carbide and Sulfinert®-Treated Sample Exposed Parts
CRNCertification
NACECompliance
Table 3: PP-3 Specifications
Products Sampled Gases and Liquids Compatible With the Materials of Construction
Material of Construction 316/316LStainless Steel
Maximum Allowable Operating Pressure 3600 psig @ -20 °F to 120 °F (248 barg @ -28 °C to 48 °C)
Connections Pipeline: ¾" MNPT (Others Available)
Product Inlet and Return: ¼" FNPT
InsertionDiameter ³⁄₈"
Features Needle Valves
Scooped Tip on Inlet Probe
Option 45° Beveled Inlet Probe
5IOM-101 MODELS: PP-1, PP-2, PP-3, and PP-F REV: C 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

Table 4: PP-F Specifications
Products Sampled Gases and Liquids Compatible With the Materials of Construction
Material of Construction 316/316LStainless Steel (Standard)
Carbon Steel
Maximum Allowable
Operating Pressure
150 ANSI Carbon Steel: 285 psig @ -20 °F to 100 °F (19 barg @ -28 °C to 37 °C)
150 ANSI Stainless Steel: 275 psig @ -20 °F to 100 °F (18 barg @ -28 °C to 37 °C)
600 ANSI Carbon Steel: 1480 psig @ -20 °F to 100 °F (102 barg @ -28 °C to 37 °C)
600 ANSI Stainless Steel: 1440 psig @ -20 °F to 100 °F (99 barg @ -28 °C to 37 °C)
900 ANSI Carbon Steel: 2200 psig @ -20 °F to 100 °F (151 barg @ -28 °C to 37 °C)
900 ANSI Stainless Steel: 2160 psig @ -20 °F to 100 °F (148 barg @ -28 °C to 37 °C)
1500 ANSICarbon Steel: 3705 psig @ -20 °F to 100 °F (255 barg @ -28 °C to 37 °C)
1500 ANSIStainless Steel: 3600 psig @ -20 °F to 100 °F (248 barg @ -28 °C to 37 °C)
Pipeline Connection
Size: 1", 2", or 3"
Rating: 150, 600, 900, or 1500 ANSI
Facing: RF or RTJ
Others Available
Outlet and Return Connections ¼" FNPT
½" FNPT
Tubing Diameter ³⁄₈" (Standard)
½"
Features Scooped Tip on Inlet Probe
Shroud
Options Inlet and Return Ball Valves
NACECompliance
6IOM-101 MODELS: PP-1, PP-2, PP-3, and PP-F REV: C 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

1.4 Equipment Diagrams
Figure 1: PP-1 Diagram
7IOM-101 MODELS: PP-1, PP-2, PP-3, and PP-F REV: C 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

Figure 2: PP-2 Diagram
8IOM-101 MODELS: PP-1, PP-2, PP-3, and PP-F REV: C 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

Figure 3: PP-3 Diagram
9IOM-101 MODELS: PP-1, PP-2, PP-3, and PP-F REV: C 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331

Figure 4: PP-F Diagram
10 IOM-101 MODELS: PP-1, PP-2, PP-3, and PP-F REV: C 13839 West Bellfort Street, Sugar Land, TX 77498 welker.com Service Department 281.491.2331
Questo manuale è adatto per i seguenti modelli