AEMC SL261 Manuale utente

AC/DC CURRENT
OSCILLOSCOPE PROBE
SL261
E N G L I S H User Manual
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

________________________________
Catalog #: 1201.51
Model #: SL261
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

Table of Contents
INTRODUCTION ..................................................................................... 2
1.1 International Electrical Symbols................................................3
1.2DenitionofMeasurementCategories .....................................3
1.3ReceivingYourShipment..........................................................3
1.4OrderingInformation.................................................................4
1.4.1AccessoriesandReplacementParts............................4
PRODUCT FEATURES............................................................................. 5
2.1Description................................................................................5
2.2Compatibility .............................................................................5
2.3Features....................................................................................6
SPECIFICATIONS................................................................................... 7
3.1ElectricalSpecications ............................................................7
3.2MechanicalSpecications ........................................................8
3.3EnvironmentalSpecications....................................................9
3.4SafetySpecications ................................................................9
3.5TypicalResponseCurves .......................................................10
OPERATION......................................................................................... 12
4.1ZeroAdjustment......................................................................12
4.2CurrentMeasurement.............................................................12
4.3 Battery Indication (Green LED)...............................................13
4.4 Peak Overload (OL) Indication (Red LED) .............................13
MAINTENANCE ................................................................................... 14
5.1Maintenance ...........................................................................14
5.2Cleaning..................................................................................14
5.3ReplacingtheBatteries...........................................................15
RepairandCalibration ..........................................................................16
TechnicalandSalesAssistance ............................................................16
Limited Warranty...........................................................................................17
WarrantyRepairs ..................................................................................17
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

2
AC/DC Current Oscilloscope Probe Model SL261
CHAPTER 1
INTRODUCTION
WARNING
The safety warnings are provided to ensure the safety of
personnel and proper operation of the instrument. Read the
instruction completely.
•Usecautiononanycircuit:potentiallyhighvoltagesandcurrents
maybepresentandmayposeashockhazard.
•Donotusetheprobeifdamaged.Alwaysconnectthecurrent
probetothemeasuringdevicebeforeitisconnectedaroundthe
conductor
•Donotuseonnoninsulatedconductorwithapotentialtoground
greaterthan600VCATIIIpollution2.Useextremecautionwhen
clampingaroundbareconductorsorbusbars.
•Beforeeachuse,inspecttheprobe;lookforcracksinhousingor
outputcableinsulation.
•
Donotuseclampinwetenvironmentorinlocationsthathazardous
gasesexist.
•Donotusetheprobeanywherebeyondthetactilebarrier.
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

AC/DC Current Oscilloscope Probe Model SL261
3
1.1 International Electrical Symbols
This symbol signifies that the instrument is protected by double or
reinforced insulation.
This symbol on the instrument indicates a WARNING and that the operator
must refer to the user manual for instructions before operating the
instrument. In this manual, the symbol preceding instructions indicates that
if the instructions are not followed, bodily injury, installation/sample and
product damage may result.
Risk of electric shock. The voltage at the parts marked with this symbol may
be dangerous.
This symbol refers to a type A current sensor. This symbol signifies that
application around and removal from HAZARDOUS LIVE conductors is
permitted.
Probe fitted with an electronic output limiter providing protection against
voltage surges caused by the accidental opening of the probe secondary
circuit to 30V max. peak.
In conformity with WEEE 2002/96/EC.
1.2 Definition of Measurement Categories
CAT II: Formeasurementsperformedoncircuitsdirectlyconnectedto
theelectricaldistributionsystem.Examplesaremeasurements
onhouseholdappliancesorportabletools.
CAT III:Formeasurementsperformedinthebuildinginstallationat
thedistributionlevelsuchasonhardwiredequipmentin xed
installationandcircuitbreakers.
CAT IV: Formeasurementsperformedattheprimaryelectricalsupply
(<1000V)suchasonprimaryovercurrentprotectiondevices,
ripplecontrolunits,ormeters.
1.3 Receiving Your Shipment
Uponreceivingyourshipment,makesurethatthecontentsareconsistent
withthepackinglist.Notifyyourdistributorofanymissingitems.Ifthe
equipmentappearstobedamaged,leaclaimimmediatelywiththecar
rier
andnotifyyourdistributoratonce,givingadetaileddescriptionofany
damage.Savethedamagedpackingcontainertosubstantiateyourclaim.
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

4
AC/DC Current Oscilloscope Probe Model SL261
1.4 Ordering Information
AC/DCCurrentProbeModelSL261
(10A-100mV/A,100A-10mV/A,BNC)..................................Cat. #1201.51
Includes a user manual.
1.4.1 Accessories and Replacement Parts
Adapter-BNCAdapterforusewithAC/DCCurrentProbe
ModelSL261&Meters8220,8333,8335&8336 .............. Cat. #2140.40
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

AC/DC Current Oscilloscope Probe Model SL261
5
CHAPTER 2
PRODUCT FEATURES
2.1 Description
TheSL261AC/DCCurrentOscilloscopeProbeexpandsoscilloscope
applicationsinindustrial,automotiveorpowerenvironments,andis
idealforanalysisandmeasurementofdistortedcurrentwaveformsand
harmonics.Theprobepermitsaccuratedisplayandmeasurementof
currentsfrom100mAto100Arms,DCto100kHzwithoutbreakinginto
thecircuit.The probeusesHalleecttechnologytomeasureACandDC
signals.Theprobeconnectsdirectlytoanoscilloscopethrougha2meter
coaxialcablewithaninsulatedBNC.
2.2 Compatibility
TheModelSL261iscompatiblewithanyanalogordigitaloscilloscopeor
othervoltage-measuringinstrumentwhichhasthefollowingfeatures:
•BNCinputconnector
•Rangecapableofdisplaying0.2to0.5Vperdivision
•Minimuminputimpedanceof1MΩ
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

6
AC/DC Current Oscilloscope Probe Model SL261
2.3 Features
ZERO
OFF
I
Battery
Compartment
Screw
Range Selection Switch
Power Indication LED
Zero Adjust Knob
Current Flow for DC Measurements
or Supply to Load for AC Measurements
Battery
Compartment Cover
Ø = 0.46"
(11.8 mm)
Peak Overload
Indication LED
Keep hands below
this point
100 mV/A
10 mV/A
WARNING: Always keep hand on the handle part of the probe.
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

AC/DC Current Oscilloscope Probe Model SL261
7
CHAPTER 3
SPECIFICATIONS
3.1 Electrical Specifications
*Referenceconditions:23°C±5°C,20to75%RH,DCto1kHz,probezeroed,1
minutewarmup,batteriesat9V±0.1V,externalmagneticeld<40A/m,noDC
component,noexternalcurrentcarryingconductor,1MΩ/100pFload,conductor
centeredinjaw.
Current Range:
100mV/A:100mAto10Apeak
10mV/A:1to100Apeak
Output Signal:1000mVpeakmax
AC Current Accuracy:
Aftercalibrationandforoneyear
(zeroprobebeforemakingmeasurement)
Range Accuracy Phase Shift
100mV/A
(50mA to 10ADC/ACpeak) ±3%ofreading±50mA <1.5°fromDCto65Hz
10mV/A
(500mA to 40ADC/ACpeak) ±4%ofreading±50mA
<1°fromDCto65Hz
10mV/A
(40A to 80ADC/ACpeak) 12%ofreading±50mA
10mV/A
(80A to 100ADC/ACpeak) 15%ofreading
Frequency Range: DCto100kHz(-3dBwithcurrentderating)
Noise:
Range10mV/A:480µV
Range100mV/A:3mV
Slew Rate:
Range10mV/A:20mV/µs
Range100mV/A:0.3V/µs
Load Impedance: >1MΩ/100pF
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com

8
AC/DC Current Oscilloscope Probe Model SL261
Insertion Impedance (50/60 Hz): 100mV/A:3µs
10mV/A:0.01Ω
Rise or Fall Time:Range100mV/A:3µs
Range10mV/A:4µs
Working Voltage: 600Vrmsmax
Common Mode Voltage: 600Vrmsmax
Inuence of Adjacent Conductor: < 0.2mA/A AC
Inuence of Conductor Position in Jaw: 0.5%ofreadingatkHz
Battery: 9Valkaline(NEDA1604A,IEC6LR61)
Low Battery: GreenLEDwhen≥6.5V
Overload Indication:
RedLEDindicatesinputgreaterthantheselectedrange
Typical Consumption: 8.6mA
Battery Life: 55hourstypical
3.2 Mechanical Specifications
Zero Adjustment: 20turnpotentiometer
Maximum Cable Diameter: 0.46" (11.8 mm)
Case Protection: IP20perIEC529
Drop Test:
1.0mon38mmofoakonconcrete;testaccordingtoIEC1010
Mechanical Shock: 100G;testperIEC68-2-27
Vibration:
TestperIEC68-2-6,frequencyrange10Hzto55Hz,amplitude0.15mm
Handle: Lexan®920A,UL94V2
Dimensions: 9.09x1.42x2.64"(231x36x67mm)
Weight: 11.6oz(330g)withbattery
Color: Lightgray
Output Lead: InsulatedcoaxialcablewithinsulatedBNCconnector
Cable Length: 6.5foot(2m)
Shop for Power Metering products online at: 1.888.610.7664
www.PowerMeterStore.com
Altri manuali per SL261
4
Indice
Altri manuali AEMC Strumento di misura

AEMC
AEMC 6422 Manuale utente

AEMC
AEMC PowerPad 8435 Guida all'installazione

AEMC
AEMC AmpFlex 300A Manuale utente

AEMC
AEMC MN375 Manuale utente

AEMC
AEMC OX 5042B Manuale utente

AEMC
AEMC MD301 Manuale utente

AEMC
AEMC PowerPad III 8336 Guida all'installazione

AEMC
AEMC 205 Manuale utente

AEMC
AEMC FlexProbe 24-3001 Manuale utente

AEMC
AEMC Simple Logger II Manuale utente