beevision 183 Manuale utente

BeeVision 183
Version 1.1
USER
MANUAL

1
CONTENTS
1.Preface ....................................................................................... 2
2.Description of The Product and Intended Use ........................... 3
2.1 Important Information ........................................................ 3
3.General Information ................................................................... 3
3.1 Overall Dimensions ............................................................. 4
3.2 Main Parts ........................................................................... 5
4.Using the Device ......................................................................... 7
4.1 Turning On/Off .................................................................... 8
4.2 Measurement Area ............................................................. 9
4.3 Volumizer .......................................................................... 10
4.4 Operation .......................................................................... 17

2
1. Preface
This document describes the usage of the BeeVision 183
dimensioning and weighing system. Permission must be obtained
from 3DTİM Elektronik A.Ş. to copy, reprint and translate this
document in whole or in part. This manual may not be published, in
whole or in part, or used without authorization for competitive
purposes. We reserve the right to make technical changes for
improvement.
This device can only be used for dimensioning and weight
measurements of 800x800x600 mm (WxDxH) opaque objects with a
maximum weight of 20 kg. Any use other than this purpose is
deemed illegal and constitutes a misuse of the machine. If it is used
in this way, all responsibility will be on the user.
BeeVision 183 is covered by a 1-year warranty. Malfunctions
resulting from user error or the use of the device not in accordance
with the user manual are not covered by the warranty.

3
2. Description of The Product and
Intended Use
BeeVision 183 is an industrial product used for dimensioning
and weighing. This device is designed for dimensioning and weighing
measurements of 800mmx800mx600mm (WxDxH) opaque loads
with a maximum weight of 20 kg. Provides flexibility in warehouses
by becoming portable with the cart shipped with the device.
Make sure that the feet that allow the device to be
attached to the vehicle from below are attached.
2.1 Important Information
• The maximum weight capacity is 20 kg.
• The device may not work properly if the slides that provide
the device movement are damaged.
• If the encoder in the moving parts is disconnected from the
gears, the device cannot measure correctly.
• BeeVision 183 cannot measure transparent objects such as
glass.
3. General Information

4
3.1 Overall Dimensions
The dimensions of the BeeVision 183 without cart are
1100x1100x1015 mm. The dimensions of the device together with
the car are 1100x1100x1570 mm. The specified dimensions are
shown in the figure below. (units are in mm)
Figure 3. 1

5
Figure 3. 2
3.2 Main Parts
Scanner: It is the orange group with handles. It moves with help of
linear guideways located on both sides of the device. The Scanner
allows the size of the object to be measured with an accuracy of 0,5
mm. Therefore, it should be used sensitively.
Weighing: It consists of the metal table where glass and legs are
joined. It measures the weight of the load placed on it with an
accuracy of 5 grams.
Monitor: This touchscreen monitor displays device controls,
measuring and weighing results.
Barcode Reader: It allows the product dimensions to be transferred
directly to the system by reading the barcodes of the products to be
measured

6
Indicator: The indicator, which is directly connected to the scale,
allows the weighing to be converted into numerical values.
Calibration of the balance is done from this section. The indicator is
located on the back of the device.
Rack Gear and Pinion: It is another element that allows the
measurement of the object to be taken. Any jamming will adversely
affect measurement accuracy.
Cart: It allows the device to be moved manually.
Figure 3. 3

7
USB 3.0 Port: There is one USB 3.0 port on the backside of the device.
In this way, users will be able to receive data from this port with the
help of a flash memory.
Ethernet Port: To communicate with any computer or a local server
for the data transfer.
Figure 3. 4
Rotary Switch: It is used to turn the system off and on. When the
switch is in position 0, all components of the system are turned off.
Wireless Antenna: Antenna, which is mounted on the dimensioner,
performs data transfer by establishing wireless communication with
a wireless modem device/PC.
4. Using the Device

8
4.1 Turning On/Off
When the power cord is inserted into the power port and
given mains voltage, turn the power switch shown in Figure 3. 4 to
position 1 and the system will be ready for use. The input mains
voltage BeeVision dimensioner must be at an interval between 100V-
240V and 50Hz-60Hz.
To turn off the device, simply unplug the power cord or turn
the power switch to ‘0’ state.
The mouse cursor is by default hidden in Volumizer UI. If you
would like to connect a mouse and a keyboard, you can
enable/disable the mouse cursor with Ctrl+Shift+M combinations on
your keyboard.
Please refer to the Software Guide for more
details on how to integrate BeeVision into your
system.

9
4.2 Measurement Area
For the device to measure the object, the object must be
placed on the glass.
There is a color transition on the glass to make sure the object
does not stick out. Objects that overflow onto the painted part of the
glass cannot be measured.
Figure 4. 1
For better measurement, you have to put the
object horizontally. Also, the bigger dimension of
the object has to be perpendicular to the linear
channels.
Indice