beevision BeeVision 272 Manuale utente

BeeVision 272
Version 1.3.2
USER
MANUAL

1
CONTENTS
1. Preface ................................................................................... 2
2. Description of The Product and Intended Use ...................... 4
2.1 Important Information ........................................................ 4
3. General Information .............................................................. 5
3.1 Overall Dimensions .............................................................. 5
3.2 Main Parts ........................................................................... 5
4. Using the Device .................................................................... 8
4.1 Turning On/Off .................................................................... 8
4.2 Measurement Area .............................................................. 9
4.3 Volumizer .......................................................................... 10
4.4 Calibration ......................................................................... 16
4.5 Operation .......................................................................... 20

2
1. Preface
This document describes the usage of the BeeVision 272
dimensioning system. Permission must be obtained from 3DTİM
Elektronik A.Ş. (3DTIM) to copy, reprint and translate this document
in whole or in part. This manual may not be published, in whole or in
part, or used without authorization for competitive purposes. 3DTIM
reserves the right to make technical changes for improvement.
BeeVision 272 can only be used for dimensioning measurements
of opaque pallets and objects with a maximum size of 2400 x 2400 x
2400 mm (WxDxH). Any use other than this purpose is deemed illegal
and constitutes a misuse of the machine. If it is used in this way, all
responsibility will be on the user.
BeeVision 272 is under warranty for 1 year. Malfunctions
resulting from user error or the use of the device not in accordance
with the user manual are not covered by the warranty.

3
Figure 1.1
Figure 1.2

4
2. Description of The Product
and Intended Use
BeeVision 272 is an industrial product used for object
dimensioning. It is designed for measuring the dimensions of opaque
pallets and objects with a maximum size of 2400 x 2400 x 2400 mm
(WxDxH). The total weight of BeeVision 272 is 27 kg.
BeeVision 272 will not function correctly in direct
sunlight. It is designed for indoor usage.
2.1 Important Information
• The maximum object size is 2400 x 2400 x 2400 mm
(WxDxH).
• The minimum object size is 300 x 300 x 300 mm (WxDxH).
• The device may not measure accurately outside the 0-40°C
temperature range.
• The fans in the units turn on and off depending on the
ambient temperature.
• BeeVision 272 cannot measure transparent objects such as
glass, plastic, or nylon.
• A monitor should be connected to BeeVision 272 for
calibration and usage.

5
3. General Information
3.1 Overall Dimensions
The dimensions of the BeeVision 272 are 2740 x 375 x
405mm (WxDxH). The specified dimensions are shown in Figure 3.1
below (units are in mm).
Figure 3.1
3.2 Main Parts
Camera Unit: There are 2 camera units located at both ends of the
device. Cameras capture 2- and 3-dimensional images from both
corners.
Mounting Brackets: Brackets allow the user to mount the device on
walls or ceilings. The distance between the device and measurement
surface is important, please refer to the installation manual for the
correct installation.

6
Sigma Profiles: There are 2 sigma profiles on which Camera Units and
Processor are mounted on.
Processor: Processor collects data from Camera Units and runs the
measurement software.
Wireless Antenna: Antenna is used for Wi-Fi connection.
Connectors:
1. POWER MAIN: This port is the main power port of the device.
2. ETHERNET: You can use this port to connect an ethernet
cable.
3. USB OUT: You can use this port to connect a USB cable.
4. USB DISP: USB port for touch screen operation of the
monitor.
5. HDMI DISP: Video output for the monitor.
6. POWER DISP: Power output for the Monitor.
7. USB BARCODE: USB connection for the handheld barcode
reader.
8. SERIAL: RS232 connection for the scale.
9. USB H1: Data port for the Camera Unit 1.
10. USB H2: Data input for the Camera Unit 2.
If you are going to add a monitor to your system, you
should use the HDMI Display port, and if the monitor
is touchscreen, you should use the USB Disp Port. If
you are going to use a 12V Monitor, don’t use the
Power Disp Port. You can supply power by simply
plugging it into any socket with the adapter.

7
The +12V input of the power_main and power_disp
connectors is the left pin when viewed from the
back of the processor head.
Figure 3.2
11. POWER H1: Power port for the Camera Unit 1.
12. POWER H2: Power port for the Camera Unit 2.
Figure 3.3

8
4. Using the Device
4.1 Turning On/Off
When the power cord is inserted into the power port and
given mains voltage, the system will be ready for use. The input
mains voltage BeeVision dimensioner must be at an interval between
100V-240V and 50Hz-60Hz.
To turn off the device, simply unplug the power cord.
The mouse cursor is by default hidden in Volumizer UI. If you
would like to connect a mouse and a keyboard, you can
enable/disable the mouse cursor with Ctrl+Shift+M combinations on
your keyboard.
Please refer to the Software Guide for more
details on how to integrate BeeVision into your
system.

9
4.2 Measurement Area
There are two Camera Units at both ends of the device. The
field of view of these cameras is shown in Figure 1.1. For the device
to measure an object, the object must be placed on a flat surface that
was used for calibration.
Figure 4.1
For maximum measurement accuracy, you must
mount the components in the positions shown in
the installation manual.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali beevision Strumento di misura