1. DESCRIPTION
Infrared cellFirmware update
button
Laser
pointer
On: short press
Off: longpress >5s
Light level cell
Status LED
Green (steady or flashing): battery charged
Steady orange: battery run down
Flashing orange: battery charging
Steady blue: paired with smartphone
Blue flashing slowly: awaiting firmware
download
Blue flashing quickly: firmware
downloading
Type B micro USB
charging≤ 1.5m
NFC zone
This configuration tool with the Close Up app aids installation and
maintenance of compatible Legrand products such as for example
motion sensors, Sarlam bulkhead lights or connected self-testing self-
contained emergency lighting units.
With this configuration tool you can configure products before, during
and after installation, whether switched on or off, using NFC and IR
communication.
The available functions are:
- Product parameter setting in IR and NFC
- Quick access to product technical documents
- Saving and sharing configuration settings
- Copy and paste configuration from one product to another
- Troubleshooting
- Adapting sensor light level meters to their environments
- Easy parameter setting of Legrand DALI sensors
- Comparison of product settings with the original file
- Display of self-contained emergency lighting unit data (fault, last time
on standby power)
- Addressing self-contained emergency lighting units (for an
addressable installation)
- Assignment of self-contained emergency lighting unit no. (escape sign
lighting)
It works with the Legrand Close Up app available on Android
platforms (Play Store ) and iOS (Apple Store )
CONTENTS PAGE
1. Description ..............................1
2. Technical characteristics ..................1
3. Commissioning ..........................2
4. Navigation ...............................2
4.1 Main menu...........................3
4.2 Manage settings files .................4
4.3 Scan product settings ................5
5. Care .....................................6
6. Standards................................6
2. TECHNICAL CHARACTERISTICS
Infrared communication technology (13m max)
Storage temperature: -20°C to +70°C
Laser pointer: Class 2 laser, 662nm ±5nm, P<1mW
LASER RADIATION
DO NOT LOOK INTO THE BEAM
CLASS 2 LASER DEVICE
Weight: 124g
Usage temperature: -5°C to +45°C
Minimum software version:
- Android version ≥ 4.4
- iOS version ≥ 9
Paired using version ≥ 4.2
Recharging: Use a mini USB cable (not supplied) for recharging the
configuration tool with a standard USB socket.

2/6
CONTENTS
Technical data sheet: S000106251EN-2 Updated: 22/07/2020 Created: 26/03/2019
Cat. No(s): 0 88240
Configuration tool
3. COMMISSIONING
On first use:
- Download the Legrand Close Up app from the “Store”
- Activate the tool
ON
- Launch the Legrand Close Upapp: the smartphone automatically
pairs with the tool*
1
2
Steady blue: paired
* If the smartphone does not pair automatically, the app menu suggests
manual pairing
3. COMMISSIONING continued
- Select the tool number indicated on the product on the smartphone
- Close the Legrand Close Up app and reopen it to launch
automatic pairing.
4. NAVIGATION
1 2
3
4
5
1 - Main menu
2 - Indicates the software version information
3 - Indicates the configuration tool (gateway) battery charge level
4 - Used to manage saved or preset settings files
5 - Used to scan a product and set its parameters

3/6
CONTENTS
Technical data sheet: S000106251EN-2 Updated: 22/07/2020 Created: 26/03/2019
Cat. No(s): 0 88240
Configuration tool
4. NAVIGATION continued
4.1 Main menu
5.0.1 Select a tool (gateway)
Used to delete the default connected tool.
In order to pair another tool (gateway), you need to quit the app and
restart it.
A selection list will then appear.
The newly selected tool will then be the default tool (gateway).
4. NAVIGATION continued
4.1 Main menu (continued)
5.0.2 Infrared level
Used to change the infraredcell power level:
0 - 2m 2 - 6m 6 - 13m
5.0.3 Laser pointer
Used to activate or deactivate the laser pointer. Once activated, it is only
triggered when scanning a product.
5.0.4 Test
Used to test whether Legrand Group lighting and detection products
which can be controlled by the tool are ON or OFF.
5.0.5 Lights calibration
Used to select one or more settings in order to copy them faster.
5.0.6 Favorite configurations
Used to create standard configurations.
5.0.7 Block addressing
Used to address emergency lighting units according to a .csv file issued
by the LVS2 supervision software or one unit at a time.

4/6
CONTENTS
Technical data sheet: S000106251EN-2 Updated: 22/07/2020 Created: 26/03/2019
Cat. No(s): 0 88240
Configuration tool
4. NAVIGATION continued
4.2 Manage settings les
Used to manage saved or preset settings files.
Tools
Files
Saved files
Import
file
content
Preset files
Delete file Change file
name
Share file
Copy
file
Move file
4. NAVIGATION continued
4.2 Manage settings les (continued)
5.0.8 Options
Used to organise files

5/6
CONTENTS
Technical data sheet: S000106251EN-2 Updated: 22/07/2020 Created: 26/03/2019
Cat. No(s): 0 88240
Configuration tool
4. NAVIGATION continued
4.3 Scan product settings
Used to scan a product and set its parameters.
Link back to the website
www.legrandoc.com
4. NAVIGATION continued
4.3 Scan product settings (continued)
5.0.9 Settings details/copy
Options
Modifiable
parameters
Options:
Restores the original settings
Link back to the website www.legrandoc.com
Compares settings with other products
Shares configuration data
Saves the configuration
Saves the selected settings
Loads other product settings

6/6
CONTENTS
Technical data sheet: S000106251EN-2 Updated: 22/07/2020 Created: 26/03/2019
Cat. No(s): 0 88240
Configuration tool
4. NAVIGATION continued
4.3 Scan product settings (continued)
5.0.10 Transfer product settings
Transfers settings
5. CARE
Do not use acetone, tar-removing cleaning agents or trichloroethylene.
Resistant to the following products: - Hexane (EN 60669-1)
- Methylated spirit
- Soapy water
- Diluted ammonia
- Bleach diluted to 10%
- Window-cleaning products
6. STANDARDS
Directive: EC
Product standards:
+ IEC 60825-1 (Safety of laser products)
+ EN/IEC 62368-1 (Audio/video, information and communication
technology equipment)
+ EN 300330 (Radio equipment)
+ EN 300328 (Electromagnetic compatibility and radio spectrum
matters)
Environmental standards:
- European directive 2002/96/EC:
WEEE (Waste Electrical and Electronic Equipment)
- European directive 2002/95/EC:
RoHS (Restriction of Hazardous Substances)
Caution:
Always test before using other special cleaning products.
Indice
Altri manuali LEGRAND Utensili