Background
Cyanoacrylate (superglue) is a proven method for developing latent fingerprints on most non-porous sur-
faces. In traditional applications, liquid glue is sublimated into a gaseous form within a closed chamber
with evidence, and reacts with moisture present in regions
where latent fingerprints are present. This reaction causes the
cyanoacrylate to polymerize and form visible ridges and detail
on latent fingerprints.
In some situations, it is impossible to place an item in a closed
chamber for fuming. Examples of these situations are: outside
windows on buildings, remote outdoor locations, and large
objects like the interior/exterior of vehicles. The Cyanowand®
uses direct heat via a butane torch to quickly vaporize
cyanoacrylate in a convenient cartridge. The fumes that are
projected can be used to develop latent prints by simply pass-
ing the wand over the surface in a controlled manner.
TECHNICAL INFORMATION
Cyanowand®and Accessories
Catalog Nos. CW100, CW200, CW300, CW400, CW4001

TI17-715ENG-REV2
2 of 4
The Cyanowand® can also be used with the Cyanoacrylate Laboratory Fuming
Chamber (FR100) or the Cyanoacrylate Fuming Chambers (FR200 and FR600)
as an alternate fuming source.
Set-up
Fueling the Cyanowand:
Warning: Butane gas is highly flammable. Do not perform refueling operation
near a heat source, electrical source, or open flame.
1. Ensure the Cyanowand switch is OFF.
2. Hold the unit vertically with the bottom-end up.
3. Place the tip of the butane container onto the brass valve at the base and press
down to engage.
4. Refill should take approximately 10 seconds. Unit is full when gas starts to
vent from bypass.
Safety Precautions
• Caution! Cyanowand barrel and tip become hot during operation. Do not touch.
• Only use in a well ventilated area or wear a dust/mist respirator to protect from
inhaling fumes.
• When using the cyanowand, it is recommended to wear gloves and safety goggles to avoid contact with
fumes.
• Do not wear contacts when using the Cyanowand®
• Do not store instrument or butane canister near an open flame, heat source, or any area that might exceed
120°F (49°C).
Figure 1: Fill Cyanowand

TI17-715ENG-REV2
3 of 4
123
4
567Figure 2: Cyanowand
Controls/Operation
1. Cyanowand Cartridge (installed)
2. Lock button
3. Ignition switch
4. Vent port
5. Fuel port
6. Flame adjustment
7. Torch lock
Operation:
1. Attach Cyanowand® cartridge (CW200, CW300, CW400, CW4001)
to end until finger tight (do not attempt to tighten further).
2. Set Flame Adjustment (6) halfway between 1 and 4.
3. Press the Lock Button (2) and slide the Ignition Switch (3) down
away from the burner and hold down.
4. Torch should light. If not, release Ignition Switch (3) and repeat
step 3 until lit.
5. Once lit, slide Torch Lock (7) to “CONT” position
6. Release Ignition Switch (3)
7. Allow 10-15 seconds for cartridge to heat. Once heated, visible
fumes should appear.
8. Fume by holding wand perpendicular and 2-3 inches above the surface.
9. Continuously fume by making small circular motions over the area being fumed (approximate fuming
time for each cartridge is in Table A)
10. When complete, slide Torch Lock (7) to OFF to extinguish flame.
11. Carefully set torch on non-flammable surface; allow to cool for several minutes before touching or storing.
Figure 3: Attach cartridge
TABLE A: Approx. Fuming Times
CW200 90 sec.
CW300 3 minutes
CW400 50 minutes

TI17-715ENG-REV2
4 of 4
12. For additional fuming, remove the cartridge by unscrewing and
replace with a new cartridge. Repeat steps 2-11.
CAUTION! When cartridge is exhausted it is VERY HOT. Remove
cartridge with enclosed tweezers (Figure 3) or wait until it completely
cools down before touching.
After Development
After fuming, developed prints should appear like prints processed with standard cyanoacrylate methods,
whitish build-up showing ridge detail. After prints are discovered, they should be photographed. If devel-
oped on a light or patterned background, an after-treatment stain along with an alternate light source and fil-
ter may be used to build contrast for imaging. Please refer to information on RAM (LV650), RAY (LV660),
Ardrox (LVS600 and LVS700), Basic Yellow (LV705, LVS500) and Rhodamine 6G (LV505).
Other methods for preserving cyanoacrylate prints are:
• Viewing and capturing with the Krimesite Imager (KSS60)
• Application of fingerprint powder (101L Black or similar) and lifting with lifting tape (144L, 144L2) or
hinge lifters (134LW). Refer to Developing Latent Prints with Powders Guide.
Maintenance
Always remove used cartridges from the Cyanowand and dispose before storage. If using the HULK car-
tridge (SCW400), store cartridge separate from kit. Used cartridges contain residual cyanoacrylate and can
form on the igniter of the wand and cause it to stop working.
Reorder Information
Figure 4: Remove cartridge
CW101 Cyanowand replacement
CW200 Standard Cartridge, Set of 10
CW300 MEGA-cartridge, Set of 10
CW400 HULK cartridge, 4 pack
CW4001 HULK cartridge, ea
SCW103 Butane Fuel, 42g