Viega Smartpress Manuale utente

Year built:
from 04/2016
en_INT
Viega Smartpress
Instructions for Use

Viega Smartpress 2 from 23

Table of contents
1About these instructions for use 4
1.1 Target groups 4
1.2 Labelling of notes 4
1.3 About this translated version 5
2Product information 6
2.1 Standards and regulations 6
2.2 Intended use 7
2.2.1 Areas of use 7
2.2.2 Media 8
2.3 Product description 8
2.3.1 Overview 8
2.3.2 Pipes 9
2.3.3 Press connectors 12
2.3.4 Markings on components 13
2.3.5 Mixed installations 14
2.4 Information for use 15
2.4.1 Chemical resistance 15
3Handling 16
3.1 Storage 16
3.2 Assembly information 16
3.2.1 Mounting instructions 16
3.2.2 Space requirements and intervals 17
3.2.3 Required tools 18
3.3 Assembly 19
3.3.1 Bending pipes 19
3.3.2 Shortening the pipes 20
3.3.3 Stripping pipes 21
3.3.4 Pressing the connection 21
3.3.5 Leakage test 23
3.4 Maintenance 23
3.5 Disposal 23
Table of contents
Viega Smartpress 3 from 23

1 About these instructions for use
Trade mark rights exist for this document; for further information, go to
viega.com/legal.
1.1 Target groups
The information in this manual is directed at heating and sanitary pro‐
fessionals and trained personnel.
Individuals without the abovementioned training or qualification are not
permitted to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
1.2 Labelling of notes
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns of possible life-threatening injury.
WARNING!
This symbol warns of possible serious injury.
CAUTION!
This symbol warns of possible injury.
NOTICE!
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
About these instructions for use
Viega Smartpress 4 from 23

1.3 About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, stand‐
ards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
Viega Smartpress 5 from 23

2 Product information
2.1 Standards and regulations
The following standards and regulations apply to Germany / Europe and
are provided as a support feature.
Scope / Notice Regulations applicable in Ger‐
many
Planning, execution, operation
and maintenance of drinking
water installations
DIN EN 1717
Planning, execution, operation
and maintenance of drinking
water installations
DIN 1988
Planning, execution, operation
and maintenance of drinking
water installations
VDI/DVGW 6023
Planning, execution, operation
and maintenance of drinking
water installations
Trinkwasserverordnung (TrinkwV)
Scope / Notice Regulations
Regulations for external corrosion
protection
DIN EN 806, Part 2
Regulations for external corrosion
protection
DIN 1988-200
Scope / Notice Regulations applicable in Ger‐
many
Requirements for material storage DIN EN 806-4, Chapter 4.2
Regulations from section: Fields of application
Regulations from section: Chemical resistance
Regulations from section: Storage
Product information
Viega Smartpress 6 from 23

Scope / Notice Regulations applicable in Ger‐
many
Test on a system that is finished
but not yet covered
DIN EN 806–4
Leakage test for water installa‐
tions
ZVSHK-Merkblatt:
"Dichtheitsprüfungen von Trink‐
wasserinstallationen mit Druckluft,
Inertgas oder Wasser"
Scope / Notice Regulations
Operation and maintenance of
drinking water installations
DIN EN 806-5
2.2 Intended use
Coordinate the use of the system for areas of use and media
other than those described with the Viega Service Center.
2.2.1 Areas of use
Use is possible in the following areas among others:
nViega Smartpress multilayer pipe (dimensionally stable with external
oxygen seal coat)
– Drinking water installations
– Heating systems
– Compressed air systems
For planning, execution, operation and maintenance of potable water
installations, observe the applicable regulations, see
Ä
„Regulations
from section: Fields of application“ on page 6.
Inform your customer or the operator of the potable water installation
that the system has to be maintained on a regular basis, see
Ä
Chapter
3.4 „Maintenance“ on page 23.
Regulations from section: Leakage test
Regulations from section: Maintenance
Drinking water installation
Maintenance
Product information
Viega Smartpress 7 from 23

The system is only intended for installation inside buildings.
Use of the system outside or in special surroundings must be agreed
with the Viega Service Center.
2.2.2 Media
The system is suitable for the following media, amongst others:
nViega Smartpress multilayer pipe (dimensionally stable with external
oxygen seal coat)
– Drinking water
– Rainwater
– Heating water
– Compressed air
Operating temperature max.
nSanitary installations: TD 70 °C
nHeating installations: TD 80 °C
Maximum operating pressure
nSanitary installations: 1.0 MPa (10 bar)
nHeating installations: 1.0 MPa (10 bar)
2.3 Product description
2.3.1 Overview
The piping system consists of various pipes and press connectors.
Fig. 1: Viega Smartpress press connectors
Installation surroundings
Operating conditions
Product information
Viega Smartpress 8 from 23

The system components are available in the following dimensions:
d 16 / 20 / 25 / 32 / 40 / 50 / 63.
2.3.2 Pipes
The following pipes are available from the system described:
Viega Smartpress multilayer pipes, with or without protective pipe, with
various thicknesses of insulation are available in coiled bundles. Dimen‐
sionally stable multilayer pipes are also available in 5 m lengths. The fol‐
lowing pipes are available from the system described:
Viega Smartpress-PE-Xc/Al/PE-Xc
dimensionally stable
with external oxygen seal coat
d 16, 20, 25, 32, 40, 50, 63
Viega Smartpress-PE-Xc/Al/PE-Xc
Type of pipe d Areas of use
Pipe in rods 16, 20, 25, 32, 40,
50, 63
Drinking water and heating
installations
Pipe without pro‐
tective pipe
16, 20, 25, 32 Drinking water and heating
installations
Pipe with protective
pipe (black, blue,
red)
16, 20, 25 Drinking water and heating
installations
Pipe with 6 mm
surrounding insula‐
tion (blue)
16, 20 Drinking water and heating
installations
Pipe with 9 mm
surrounding insula‐
tion (blue)
25 Drinking water and heating
installations
Viega Smartpress PERT/Al/PERT
dimensionally stable
with external oxygen seal coat
d 16, 20
Product information
Viega Smartpress 9 from 23

Viega Smartpress PERT/Al/PERT
Type of pipe d Areas of use
Pipe without pro‐
tective pipe
16, 20 Drinking water and heating
installations
Pipe with protective
pipe (black)
16, 20 Drinking water and heating
installations
Pipe with 6 mm
surrounding insula‐
tion (blue)
16, 20 Drinking water and heating
installations
Pipe with 9 mm
surrounding insula‐
tion (grey)
16, 20 Drinking water and heating
installations
Only pipe clamps with chloride-free sound insulating inlays should be
used to secure the pipes.
Observe the general rules of fixing technology:
nDo not use fixed pipelines as a support for other pipelines and com‐
ponents.
nDo not use pipe hooks.
nObserve distance to connectors.
nObserve the expansion direction: Plan fixed and gliding points.
Make sure to affix the pipelines in such a way as to de-couple them
from the installation body, so that they cannot transfer any structure-
borne sound, resulting from thermal expansion or possible pressure
surges, onto the installation body or other components.
Observe the following fixing intervals:
Interval between the pipe clamps
d x s
[mm]
Horizontal
Multilayer pipe [m]
Vertical
Multilayer pipe [m]
16 x 2.0 1.00 1.30
20 x 2.3 1.00 1.30
25 x 2.8 1.50 1.95
32 x 3.2 2.00 2.60
40 x 3.5 2.00 2.60
50 x 4.0 2.50 3.25
63 x 4.5 2.50 3.25
Laying and fixing pipes
Product information
Viega Smartpress 10 from 23
Indice
Altri manuali Viega Utensili

Viega
Viega Pressgun Picco Manuale utente

Viega
Viega 6 PlusPress Manuale utente

Viega
Viega PureFlow 50030 Foglio di istruzioni

Viega
Viega Pressgun Picco 6 Plus Manuale utente

Viega
Viega PureFlow Foglio di istruzioni

Viega
Viega 50000 Foglio di istruzioni

Viega
Viega 2489.1 Manuale utente

Viega
Viega Pressgun 5 Manuale utente

Viega
Viega MegaPress Z3 Actuator Manuale utente

Viega
Viega Megapress Manuale utente